Researcher profile

S. Chernov

S. Chernov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Multimode Objective Lens for Momentum Microscopy and XPEEM: Experiments

A new type of objective lens has recently been proposed for use in X-ray photoemission electron microscopes (XPEEMs) and momentum microscopes. Adding a ring electrode concentric with the extractor allows the field in the gap between the sample and the extractor to be shaped. Forming a lens field in this gap reduces the field strength at the sample by up to an order of magnitude. This mitigates the risk of field emission, particularly for cleaved samples with sharp edges. A retarding field can redirect all slow electrons, thus eliminating the primary contribution to the space-charge interaction. Here we present the first experimental investigation of the new lens, examining its performance at photon energies ranging from the extreme ultraviolet produced by a high-harmonic generation (HHG)-based source to soft and hard X-rays at two synchrotron facilities. The gap lens in a region without electrodes enables large working distances up to 23 mm. Reduced aberrations allow for larger fields of view in both k-space and real-space imaging, with resolutions comparable to those of conventional cathode lenses. However, field strengths are an order of magnitude smaller. The zero-field mode enables the study of 3D structured objects and is therefore beneficial for small cleaved samples as well as for operando devices involving top electrodes. The repeller mode reduces space-charge effects, but results in a smaller k-field diameter. This reduction ranges from 10% at hard X-ray energies to 50% in the XUV range. The usable energy interval is also reduced by a factor of two. In time-of-flight XPEEM mode the raw data show a resolution of 250 nm, which can be improved to better than 100 nm through data processing.

preprint2022arXiv

Flares and their echoes can help distinguish photon rings from black holes with space-Earth very long baseline interferometry

Photon rings near the edge of a black hole shadow is supposed to be a unique tool to validate general relativity and provide reliable measurements of principal black hole parameters: spin and mass. Such measurements are possible though only for nearby supermassive black holes (SMBH) with Space-Earth Very Long Baseline Interferometry (S-VLBI) in the submillimeter wavelength range. For subrings to be distinguished S-EVLBI observations with long baselines at the Lagrangian Sun-Earth L2 libration point are needed. However, the average fluxes of nearby SMBH: Sagittarius A$^\ast$ (Sgr A$^\ast$) and M87$^\ast$ -- $F_ν\sim 1$ Jy, are still insufficient to detect the signal from the photon rings with even such long baselines. We argue that only manifestations of flares in the submillimeter waveband in their accretion disks can reveal observable signals from the photon rings with the S-EVLBI at L2. Such observations will become possible within the planned join program of the {\it Event Horizon Telescope} (EHT) and {\it Millimetron Space Observatory} (MSO), and within the planned {\it next generation EHT} (ngEHT) project. Two different observational tests for photons rings are discussed. The first one involves observations of a time series of responds from subsequent subrings as can be seen in a 1D visibility function within the join EHT-MSO configuration, the second one -- measurements of an increase of the angle between subsequent subrings in the 2D VLBI image which can be obtained within the ngEHT project.

preprint2019arXiv

Band structure tuning of Heusler compounds revisited: Spin- and momentum-resolved electronic structure analysis of compounds with different band filling

Spin-filtered time-of-flight photoelectron momentum microscopy reveals a systematic variation of the band structure within a series of highly spin-polarized ferromagnetic Heusler compounds with increasing number of valence electrons (Co2MnGa, Co2MnSi and Co2Fe0.4Mn0.6Si). The positions of the Fermi energy for minority and majority electrons deviate strongly from a simple band-filling model. Photoexcitation at h$ν$=6.05 eV (4th harmonic of a Ti:sapphire laser) gives access to the spin-polarization texture P(EB,kx,ky) of the bulk bands in a (kx,ky)-range with diameter 1.4Å$^{-1}$ and energies from the Fermi energy EF to a binding energy of EB=2 eV. The minority bands of Co2MnGa cross the Fermi level, inhibiting half-metallicity; the crossing points allow a precise adjustment of experimental and theoretical majority and minority bands, requiring shifts in opposite directions. The top of the minority band lies only 0.15 eV above EF, i.e. Co2MnGa is much closer to being half-metallic than predicted by calculations. For half-metallic Co2MnSi and Co2Fe0.4Mn0.6Si clear minority band gaps are visible, the topmost occupied minority bands lie 0.5 and 0.35 eV below EF, in reasonable agreement with theory; the exchange splitting is significantly smaller than in theory. The comparison of all three compounds uncovers the surprising fact that with increasing number of valence electrons the frontier majority bands (close to EF) exhibit an increasing deficiency in filling, in comparison with the prediction of a DFT calculation. The same trend is visible in comparison with a DMFT calculation. For s-polarized excitation both half-metallic compounds exhibit nearly complete positive spin polarization close to EF, consistent with previous work in literature.

preprint2019arXiv

Narrow-Band Pulsed Electron Source Based on Near-Threshold Photoionization of Cs in a Magneto-Optical Trap

The newly developed method of time-of-flight (ToF) momentum microscopy was used to analyse the cold electron emission from a Cs 3D magneto-optical trap (MOT). Three-step resonant photoionization was implemented via two intermediate states (6P3/2 pumped with 852 nm laser and 7S1/2 with 1470 nm) and a tuneable femtosecond Ti:sapphire laser for the final ionization step. The magnetic field of the MOT is switched off during the photoionization step. The natural bandwidth of the fs-laser is reduced to 4 meV using optical spectral filters. Precise tuning of the photon energy makes it possible to observe the transition regime between direct photoemission into the open continuum and field induced ionization of highly-excited Rydberg states. The paths can be identified by their characteristic dependency on the extraction field and on the Ti:sapphire polarization. ToF analysis allowed us to disentangle the ionization paths and the dependence of the spatio-temporal distribution of the cold electrons on the polarization of the ionizing laser.