Researcher profile

S. Biri

S. Biri contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
6works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2015arXiv

Experiments with biased side electrodes in electron cyclotron resonance ion sources

The output of highly charged ions from an electron cyclotron resonance ion source (ECRIS) consists of ionic losses from a highly confined plasma. Therefore, an increase of the output of the ions of interest always is a compromise between an increase in the confinement and an increase of the losses.One route towards a solution consists of attacking the losses in directions (i.e., radial directions) that do not contribute to the required output. This was demonstrated in an experiment (using the Kei ECRIS at NIRS, Japan) where radial losses were electrostatically reduced by positively biasing one set of six side electrodes surrounding the plasma in side-ward directions attached (insulated) to the cylindrical wall of the plasma chamber. Recently new studies were performed in two laboratories using two essentially different ion sources. At the BioNano ECRIS (Toyo University, Japan) various sets of electrodes were used; each of the electrodes could be biased individually. At the Atomki ECRIS (Hungary), one movable, off-axis side electrode was applied in technically two versions. The measurements show indeed a decrease of ionic losses but different effectivities as compared to the biased disk.

preprint2015arXiv

Fast camera studies at an electron cyclotron resonance table plasma generator

A simple table-size ECR plasma generator operates in the ATOMKI without axial magnetic trap and without any particle extraction tool. Radial plasma confinement is ensured by a NdFeB hexapole. The table-top ECR is a simplified version of the 14 GHz ATOMKI-ECRIS. Plasma diagnostics experiments are planned to be performed at this device before installing the measurement setting at the big ECRIS. Recently, the plasma generator has been operated in pulsed RF mode in order to investigate the time evolution of the ECR plasma in two different ways. (1) The visible light radiation emitted by the plasma was investigated by the frames of a fast camera images with 1 ms temporal resolution. Since the visible light photographs are in strong correlation with the two-dimensional spatial distribution of the cold electron components of the plasma it can be important to understand better the transient processes just after the breakdown and just after the glow. (2) The time-resolved ion current on a specially shaped electrode was measured simultaneously in order to compare it with the visible light photographs. The response of the plasma was detected by changing some external setting parameters (gas pressure and microwave power) and was described in this paper.

preprint2015arXiv

Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

A synthesis technology of endohedral fullerenes such as Fe@C60 has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C60 was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

preprint2015arXiv

Status of the Bio-Nano electron cyclotron resonance ion source at Toyo University

In the paper, the material science experiments, carried out recently using the Bio-Nano electron cyclotron resonance ion source (ECRIS) at Toyo University, are reported. We have investigated several methods to synthesize endohedral C60 using ion-ion and ion-molecule collision reaction in the ECRIS. Because of the simplicity of the configuration, we can install a large choice of additional equipment in the ECRIS. The Bio-Nano ECRIS is suitable not only to test the materials production but also to test technical developments to improve or understand the performance of an ECRIS.

preprint2015arXiv

Synthesis of endohedral iron-fullerenes by ion implantation

In this paper, we discuss the results of our study of the synthesis of endohedral iron-fullerenes. A low energy Fe+ ion beam was irradiated to C60 thin film by using a deceleration system. Fe+-irradiated C60 thin film was analyzed by high performance liquid chromatography and laser desorption/ionization time-of-flight mass spectrometry. We investigated the performance of the deceleration system for using a Fe+ beam with low energy. In addition, we attempted to isolate the synthesized material from a Fe+-irradiated C60 thin film by high performance liquid chromatography.

preprint2015arXiv

Two-frequency heating technique at the 18 GHz electron cyclotron resonance ion source of the National Institute of Radiological Sciences

The two-frequency heating technique was studied to increase the beam intensities of highly charged ions provided by the high-voltage extraction configuration (HEC) ion source at the National Institute of Radiological Sciences (NIRS). The observed dependences on microwave power and frequency suggested that this technique improved plasma stability but it required precise frequency tuning and more microwave power than was available before 2013. Recently, a new, high-power (1200 W) wide bandwidth (17.1-18.5 GHz) travelling-wave-tube amplifier (TWTA) was installed. After some single tests with klystron and TWT amplifiers the simultaneous injection of the two microwaves has been successfully realized. The dependence of highly charged ions (HCI) currents on the superposed microwave power was studied by changing only the output power of one of the two amplifiers, alternatively. While operating the klystron on its fixed 18.0 GHz, the frequency of the TWTA was swept within its full limits (17.1-18.5 GHz), and the effect of this frequency on the HCI-production rate was examined under several operation conditions. As an overall result, new beam records of highly charged argon, krypton, and xenon beams were obtained at the NIRS-HEC ion source by this high-power two-frequency operation mode.