Researcher profile

S. B. Shaulov

S. B. Shaulov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2019arXiv

New complex EAS installation of the Tien Shan Mountain Cosmic Ray Station

We present a description of the new complex installation for the study of extensive air showers which was created at the Tien Shan mountain cosmic ray station, as well as the results of the test measurements made there in 2014-2016. At present, the system for registration of electromagnetic shower component consists of $\sim$100 detector points built on the basis of plastic scintillator plates with the sensitive area of 0.25m$^2$ and 1m$^2$, spread equidistantly over $\sim$10$^4$m$^2$ space. The dynamic range of scintillation amplitude measurements is currently about $(3-7)\cdot 10^4$, and there is a prospect of it being extended up to $\sim$10$^6$. The direction of shower arrival is defined by signal delays from a number of the scintillators placed cross-wise at the periphery of the detector system. For the investigation of nuclear active shower components there was created a multi-tier 55m$^2$ ionization-neutron calorimeter with a sum absorber thickness of $\sim$1000g/cm$^2$, typical spatial resolution of the order of 10cm, and dynamic range of ionization measurement channel about $\sim$10$^5$. Also, the use of saturation-free neutron detectors is anticipated for registration of the high- and low-energy hadron components in the region of shower core. A complex of underground detectors is designed for the study of muonic and penetrative nuclear-active components of the shower. The full stack of data acquisition, detector calibration, and shower parameters restoration procedures are now completed, and the newly obtained shower size spectrum and lateral distribution of shower particles occur in agreement with conventional data. Future studies in the field of $10^{14}-10^{17}$eV cosmic ray physics to be held at the new shower installation are discussed.

preprint2012arXiv

Results on the primary CR spectrum and composition reconstructed with the SPHERE-2 detector

First preliminary results of the balloon-borne experiment SPHERE-2 on the all-nuclei primary cosmic rays (PCR) spectrum and primary composition are presented. The primary spectrum in the energy range $10^{16}$--$5\cdot10^{17}$ eV was reconstructed using characteristics of Vavilov-Cherenkov radiation of extensive air showers (EAS), reflected from a snow surface. Several sources of systematic uncertainties of the spectrum were analysed. A method for separation of the primary nuclei' groups based on the lateral distribution function' (LDF) steepness parameter is presented. Preliminary estimate of the mean light nuclei' fraction $f_{30-150}$ at energies $3\cdot10^{16}$--$1.5\cdot10^{17}$ eV was performed and yielded $f_{30-150}$= (21$\pm$11)%.

preprint2012arXiv

Status of the SPHERE experiment

Here is presented the current state of the SPHERE-2 balloon-borne experiment. The detector is elevated up to 1 km above the snow surface and registers the reflected Vavilov-Cherenkov radiation from extensive air showers. This method has good sensitivity to the mass-composition of the primary cosmic rays due to its high resolution near the shower axis. The detector consists of a 1500 mm spherical mirror with a 109 PMT cluster in its focus. The electronics record a signal pulse profile in each PMT. In the last 2 years the detector was upgraded: time resolution of pulse registration was enhanced up to 12.5 ns, channel sensitivity was increased by a factor of 3, a new LED-based relative PMT calibration method was introduced, and new hardware and etc. was installed.