Researcher profile

Ryo Toda

Ryo Toda contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

A Simple Experimental Setup for Simultaneous Superfluid-response and Heat-capacity Measurements for Helium in Confined Geometries

Torsional oscillator (TO) is an experimental technique which is widely used to investigate superfluid responses in helium systems confined in porous materials or adsorbed on substrates. In these systems, heat capacity (HC) is also an important quantity to study the local thermodynamic properties. We have developed a simple method to incorporate the capability of HC measurement into an existing TO without modifying the TO itself. By inserting a rigid thermal isolation support made of alumina and a weak thermal link made of fine copper wires between a standard TO and the mixing chamber of a dilution refrigerator in parallel, we were able to carry out simultaneous TO and HC measurements on exactly the same helium sample, i.e., four atomic layers of $^4$He adsorbed on graphite, with good accuracies down to 30 mK. The data reproduced very well the previous workers' results obtained independently using setups optimized for individual measurements. This method is conveniently applicable to a variety of experiments where careful comparisons between results of TO and HC measurements are crucial. We describe how to design the thermal isolation support and the weak thermal link to manage conflicting requirements in the two techniques.

preprint2021arXiv

Construction of Continuous Magnetic Cooling Apparatus with Zinc Soldered PrNi$_5$ Nuclear Stages

We report design details of the whole assembly of a compact and continuous nuclear demagnetization refrigerator (CNDR) with two PrNi$_5$ nuclear stages, which can keep temperature below 1 mK continuously, and test results of a new thermal contact method for the PrNi$_5$ stage using Zn soldering rather than Cd soldering. By measuring a residual electrical resistance of a short test piece, the thermal contact resistivity between the PrNi$_5$ rod and an Ag wires thermal link was estimated as $1.8\pm0.1 \times 10^{-4} T^{-1}~\rm{Km^2W^{-1}}$. Based on this value and 2D numerical and 1D analytical thermal simulations, the largest possible temperature gradient throughout the nuclear stage was calculated to be negligibly small ($\leq$ 2 %) at 1 mK under a 10 nW heat leak, the expected cooling power of the CNDR.

preprint2019arXiv

Performances of a Compact Shielded Superconducting Magnet for Continuous Nuclear Demagnetization Refrigerator

We have successfully developed and tested a compact shielded superconducting (SSC) magnet with a FeCoV magnetic shield. This was developed for the PrNi$_5$ based nuclear demagnetization refrigerator which can keep temperatures below 1 mK continuously (CNDR) [Toda $\it{et~al}$., J. Phys.: Conf. Ser. $\bf{969}$, 012093 (2018)]. The clear bore diameter, outer diameter, and total length of the SSC magnet are 22, 42 and 169 mm, respectively, and it produces the maximum field of 1.38 T at an electric current of 6 A. In order to realize both the compactness and the high shielding performance, we carefully chose material and optimized design of the magnetic shield by numerical simulations of the field distribution based on measured magnetization curves of several candidate materials with high permeability. We also measured a heat generated by sweeping the SSC magnet in vacuum to be 230 mJ per field cycle. This value agrees very well with an estimation from the measured magnetic hysteresis of the superconducting wire used to wind the magnet.