Researcher profile

Ruohong Li

Ruohong Li contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2023arXiv

Causal inference methods for combining randomized trials and observational studies: a review

With increasing data availability, causal effects can be evaluated across different data sets, both randomized controlled trials (RCTs) and observational studies. RCTs isolate the effect of the treatment from that of unwanted (confounding) co-occurring effects but they may suffer from unrepresentativeness, and thus lack external validity. On the other hand, large observational samples are often more representative of the target population but can conflate confounding effects with the treatment of interest. In this paper, we review the growing literature on methods for causal inference on combined RCTs and observational studies, striving for the best of both worlds. We first discuss identification and estimation methods that improve generalizability of RCTs using the representativeness of observational data. Classical estimators include weighting, difference between conditional outcome models, and doubly robust estimators. We then discuss methods that combine RCTs and observational data to either ensure uncounfoundedness of the observational analysis or to improve (conditional) average treatment effect estimation. We also connect and contrast works developed in both the potential outcomes literature and the structural causal model literature. Finally, we compare the main methods using a simulation study and real world data to analyze the effect of tranexamic acid on the mortality rate in major trauma patients. A review of available codes and new implementations is also provided.

preprint2021arXiv

Nuclear magnetic resonance of ion implanted $^8$Li in ZnO

We report on the stability and magnetic state of ion implanted $^8$Li in single crystals of the semiconductor ZnO using $β$-detected nuclear magnetic resonance. At ultradilute concentrations, the spectra reveal distinct Li sites from 7.6 to 400 K. Ionized shallow donor interstitial Li is stable across the entire temperature range, confirming its ability to self-compensate the acceptor character of its (Zn) substitutional counterpart. Above 300 K, spin-lattice relaxation indicates the onset of correlated local motion of interacting defects, and the spectra show a site change transition from disordered configurations to substitutional. Like the interstitial, the substitutional shows no resolved hyperfine splitting, indicating it is also fully ionized above 210 K. The electric field gradient at the interstitial $^8$Li exhibits substantial temperature dependence with a power law typical of non-cubic metals.

preprint2020arXiv

Development of a continuously tunable titanium-sapphire laser system for the ARIEL laser ion source

A concept for continuously tunable titanium-sapphire (Ti:Sa) lasers using dispersion prisms is under investigation for the ARIEL (Advanced Rare IsotopE Laboratory) laser ion source at TRIUMF (Canada's particle accelerator center). Wavelength selection for pulsed Ti:Sa lasers used in hot cavity laser resonance ionization spectroscopy is usually done with birefringent filters (BRFs) and etalons or diffraction gratings. For resonance ionization spectroscopy a laser system allowing a continuous wavelength scan is necessary. Tunable lasers based on BRFs and etalons have high output powers however require synchronized optimization for continuous laser wavelength scans and are therefore laborious to use in scanning applications. Diffraction grating tuned lasers can provide continuous wavelength scan over 200 nm range but typically have lower output laser power due to the grating deformation under high pumping power. Aiming to overcome both shortcomings a laser design based on prisms as dispersing element has been revisited. Simulations on the beam path and optical reflectivity are done which show that these losses can be minimized to around 0.04 % for a tuning range from 700 nm up to 920 nm. Further improvement on the tuning range and reduction on the linewidth will be pursued.

preprint2020arXiv

Investigation of Ionic and Anomalous Magnetic Behavior in CrSe$_2$ Using $^8$Li $β$-NMR

We have studied a mosaic of 1T-CrSe$_2$ single crystals using $β$-detected nuclear magnetic resonance of $^{8}$Li from 4 to 300 K. We identify two broad resonances that show no evidence of quadrupolar splitting, indicating two magnetically distinct environments for the implanted ion. We observe stretched exponential spin lattice relaxation and a corresponding rate ($1/T_1$) that increases monotonically above 200 K, consistent with the onset of ionic diffusion. A pronounced maximum in $1/T_1$ is observed at the low temperature magnetic transition near 20 K. Between these limits, $1/T_1$ instead exhibits a broad minimum with a remarkable absence of strong features in the vicinity of structural and magnetic transitions between 150 and 200 K. Together, the results suggest $^{8}$Li$^{+}$ site occupation within the van der Waals gap between CrSe$_2$ trilayers. Possible origins of the two environments are discussed.

preprint2020arXiv

Local electronic and magnetic properties of the doped topological insulators Bi$_{2}$Se$_{3}$:Ca and Bi$_{2}$Te$_{3}$:Mn investigated using ion-implanted $^{8}$Li $β$-NMR

We report $β$-detected nuclear magnetic resonance ($β$-NMR) measurements in Bi$_{2}$Se$_{3}$:Ca (BSC) and Bi$_{2}$Te$_{3}$:Mn (BTM) single crystals using $^{8}$Li$^{+}$ implanted to depths on the order of 100 nm. Above $\sim 200$ K, spin-lattice relaxation (SLR) reveals diffusion of $^{8}$Li$^{+}$, with activation energies of $\sim 0.4$ eV ($\sim 0.2$ eV) in BSC (BTM). At lower temperatures, the nuclear magnetic resonance (NMR) properties are those of a heavily doped semiconductor in the metallic limit, with Korringa relaxation and a small, negative, temperature-dependent Knight shift in BSC. From this, we make a detailed comparison with the isostructural tetradymite Bi$_{2}$Te$_{2}$Se (BTS) [McFadden et al., Phys Rev. B 99, 125201 (2019)]. In the magnetic BTM, the effects of the dilute Mn moments predominate, but remarkably the $^{8}$Li signal is not wiped out through the magnetic transition at 13 K, with a prominent critical peak in the SLR that is suppressed in a high applied field. This detailed characterization of the $^{8}$Li NMR response is an important step towards using depth-resolved $β$-NMR to study the low-energy properties of the chiral topological surface state (TSS). With the bulk NMR response now established in several Bi$_{2}$Ch$_{3}$ tetradymite topological insulators (TIs), the prospect of directly probing their chiral TSS using the depth resolution afforded by $β$-NMR remains strong.

preprint2016arXiv

Continuously tunable pulsed Ti:Sa laser self-seeded by an extended grating cavity

A continuously tunable titanium:sapphire (Ti:Sa) laser self-seeded by an extended grating cavity was demonstrated and characterized. By inserting a partially reflecting mirror inside the cavity of a classic single-cavity grating laser, two oscillators are created: a broadband power oscillator, and a narrowband oscillator with a prism beam expander and a diffraction grating in Littrow configuration. By coupling the grating cavity oscillation into the power oscillator, a power-enhanced narrow-linewidth laser oscillation is achieved. Compared to the classic grating laser, this simple modification significantly increases the laser output power without considerably broadening the linewidth. With most of the oscillating laser power confined inside the broadband power cavity and lower power incident onto the grating, the new configuration also allows higher pump power, which is typically limited by the thermal deformation of the grating coating at high oscillation power.