Source author record

Ruirui Fan

Ruirui Fan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Timing performance simulation for 3D 4H-SiC detector

To meet high radiation challenge for detectors in future high-energy physics, a novel 3D 4H-SiC detector was investigated. SiC detectors could potentially operate in radiation harsh and room temperature environment because of its high thermal conductivity and high atomic displacement threshold energy. 3D structure, which decouples thickness and distance between electrodes, further improves timing performance and radiation hardness of the detector. We developed a simulation software - RASER (RAdiation SEmiconductoR) to simulate the time resolution of planar and 3D 4H-SiC detectors with different parameters and structures, and the reliability of the software is verified by comparing time resolution results of simulation with data. The rough time resolution of 3D 4H-SiC detector was estimated, and the simulation parameters could be used as guideline to 3D 4H-SiC detector design and optimization.

preprint2020arXiv

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

preprint2019arXiv

Measurements of differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li reaction in the neutron energy range from 1.0 eV to 2.5 MeV

Differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li, $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions have been measured at CSNS Back-n white neutron source. Two enriched (90%) $^{10}$B samples 5.0 cm in diameter and ~85.0 $μ$g/cm$^{2}$ in thickness each with an aluminum backing were prepared, and back-to-back mounted at the sample holder. The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array (LPDA) system. The neutron energy E$_{n}$ was determined by TOF (time-of-flight) method, and the valid $α$ events were extracted from the E$_{n}$-Amplitude two-dimensional spectrum. With 15 silicon detectors, the differential cross sections of $α$-particles were measured from 19.2° to 160.8°. Fitted with the Legendre polynomial series, the ($n, α$) cross sections were obtained through integration. The absolute cross sections were normalized using the standard cross sections of the $^{10}$B($n, α$)$^{7}$Li reaction in the 0.3 - 0.5 MeV neutron energy region. The measurement neutron energy range for the $^{10}$B($n, α$)$^{7}$Li reaction is 1.0 eV $\le$ En < 2.5 MeV (67 energy points), and for the $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions is 1.0 eV $\le$ En < 1.0 MeV (59 energy points). The present results have been analyzed by the resonance reaction mechanism and the level structure of the $^{11}$B compound system, and compared with existing measurements and evaluations.

preprint2014arXiv

Physical Design and Monte Carlo Simulations of a Space Radiation Detector onboard the SJ-10 satellite

A radiation gene box (RGB) onboard the SJ-10 satellite is a device carrying mice and drosophila cells to determine the biological effects of space radiation environment. The shielded fluxes of different radioactive sources were calculated and the linear energy transfers of gamma-rays, electrons, protons and alpha-particles in tissue were acquired using A-150 tissue-equivalent plastic. Then, a conceptual model of a space radiation instrument employing three semiconductor sub-detectors for deriving the charged and uncharged radiation environment of the RGB was designed. The energy depositions in the three sub-detectors were classified into fifteen channels (bins) in an algorithm derived from the Monte Carlo method. The physical feasibility of the conceptual instrument was also verified by Monte Carlo simulations.