Researcher profile

Roxanne Guenette

Roxanne Guenette contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Comparing generator predictions of transverse kinematic imbalance in neutrino-argon scattering

The largest uncertainties in estimating neutrino-nucleus interaction cross sections lie in the incomplete understanding of nuclear effects. A powerful tool to study nuclear effects is Transverse Kinematic Imbalance. This paper presents the first detailed comparison of the predictions of multiple event generators for distributions associated with Transverse Kinematic Imbalance for neutrino interactions on argon. Predictions for muon neutrinos interacting with an argon target are obtained using four standard neutrino event generation tools (GENIE, NuWro, GiBUU and NEUT). Example opportunities for discrimination between nuclear models leveraging future measurements are highlighted. The predictions shown in this paper are motivated by studying muon neutrinos from the Fermilab Booster Neutrino Beam interacting at the location of the MicroBooNE liquid argon time projection chamber, but the methods directly apply to other accelerator-based liquid argon neutrino experiments such as SBND, ICARUS and DUNE.

preprint2022arXiv

SoLAr: Solar Neutrinos in Liquid Argon

SoLAr is a new concept for a liquid-argon neutrino detector technology to extend the sensitivities of these devices to the MeV energy range - expanding the physics reach of these next-generation detectors to include solar neutrinos. We propose this novel concept to significantly improve the precision on solar neutrino mixing parameters and to observe the "hep branch" of the proton-proton fusion chain. The SoLAr detector will achieve flavour-tagging of solar neutrinos in liquid argon. The SoLAr technology will be based on the concept of monolithic light-charge pixel-based readout which addresses the main requirements for such a detector: a low energy threshold with excellent energy resolution (approximately 7%) and background rejection through pulse-shape discrimination. The SoLAr concept is also timely as a possible technology choice for the DUNE "Module of Opportunity", which could serve as a next-generation multi-purpose observatory for neutrinos from the MeV to the GeV range. The goal of SoLAr is to observe solar neutrinos in a 10 ton-scale detector and to demonstrate that the required background suppression and energy resolution can be achieved. SoLAr will pave the way for a precise measurement of the 8-B flux, an improved precision on solar neutrino mixing parameters, and ultimately lead to the first observation of hep neutrinos in the DUNE Module of Opportunity.

preprint2020arXiv

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

preprint2011arXiv

The ArgoNeuT experiment

The ArgoNeuT experiment features a 175 liter Liquid Argon (LAr) Time Projection Chamber (TPC) that was located upstream of the MINOS near detector in the NuMI neutrino beam at Fermilab. The project is part of the LAr TPC development program in the US and has helped initiate the development of simulation and reconstruction tools for LAr TPCs. In addition to its development goals, ArgoNeuT will perform several cross-section measurements on Ar in the few-GeV energy range. A total of 1.35E20 Protons on Target were accumulated and data analysis is ongoing. I will review the experiment and its status, as well as preliminary results from the data analysis.