Researcher profile

Rosalie McGurk

Rosalie McGurk contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Liger at Keck Observatory: Design of Imager Optical Assembly and Spectrograph Re-Imaging Optics

Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module and lenslet array. Each imager component and the first two RIO mechanisms are assembled and individually aligned on the same optical plate. Baffling suppresses background radiation and scattered light, and a pupil viewing camera allows the imager detector to focus on an image of the telescope pupil. The optical plate mounts on an adapter frame for alignment of the overall system. The imager and RIO will be characterized in a cryogenic test chamber before installation in the final science cryostat.

preprint2022arXiv

Liger at Keck Observatory: Design of the Data Reduction System and Software Interfaces

Liger is a second generation near-infrared imager and integral field spectrograph (IFS) for the W. M. Keck Observatory that will utilize the capabilities of the Keck All-sky Precision Adaptive-optics (KAPA) system. Liger operates at a wavelength range of 0.81 μm - 2.45 μm and utilizes a slicer and a lenslet array IFS with varying spatial plate scales and fields of view resulting in hundreds of modes available to the astronomer. Because of the high level of complexity in the raw data formats for the slicer and lenslet IFS modes, Liger must be designed in conjunction with a Data Reduction System (DRS) which will reduce data from the instrument in real-time and deliver science-ready data products to the observer. The DRS will reduce raw imager and IFS frames from the readout system and provide 2D and 3D data products via custom quick-look visualization tools suited to the presentation of IFS data. The DRS will provide the reduced data to the Keck Observatory Archive (KOA) and will be available to astronomers for offline post-processing of observer data. We present an initial design for the DRS and define the interfaces between observatory and instrument software systems.

preprint2022arXiv

Liger at Keck Observatory: Imager Detector and IFS Pick-off Mirror Assembly

Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 $μ$m with spectral resolving powers of R$\sim$4,000-10,000. Liger makes use of a sequential imager and spectrograph design allowing for simultaneous observations. There are two spectrograph modes: a lenslet with high spatial sampling of 14 and 31 mas, and a slicer with 75 and 150 mas sampling with an expanded field of view. Two pick-off mirrors near the imager detector direct light to these two IFS channels. We present the design and structural analysis for the imager detector and IFS pick-off mirror mounting assembly that will be used to align and maintain stability throughout its operation. A piezoelectric actuator will be used to step through $\rm3\,mm$ of travel during alignment of the instrument to determine the optimal focus for both the detector and pick-off mirrors which will be locked in place during normal operation. We will demonstrate that the design can withstand the required gravitational and shipping loads and can be aligned within the positioning tolerances for the optics.

preprint2014arXiv

Commissioning ShARCS: the Shane Adaptive optics infraRed Camera-Spectrograph for the Lick Observatory 3-m telescope

We describe the design and first-light early science performance of the Shane Adaptive optics infraRed Camera-Spectrograph (ShARCS) on Lick Observatory's 3-m Shane telescope. Designed to work with the new ShaneAO adaptive optics system, ShARCS is capable of high-efficiency, diffraction-limited imaging and low-dispersion grism spectroscopy in J, H, and K-bands. ShARCS uses a HAWAII-2RG infrared detector, giving high quantum efficiency (>80%) and Nyquist sampling the diffraction limit in all three wavelength bands. The ShARCS instrument is also equipped for linear polarimetry and is sensitive down to 650 nm to support future visible-light adaptive optics capability. We report on the early science data taken during commissioning.

preprint2014arXiv

ShaneAO: wide science spectrum adaptive optics system for the Lick Observatory

A new high-order adaptive optics system is now being commissioned at the Lick Observatory Shane 3-meter telescope in California. This system uses a high return efficiency sodium beacon and a combination of low and high-order deformable mirrors to achieve diffraction-limited imaging over a wide spectrum of infrared science wavelengths covering 0.8 to 2.2 microns. We present the design performance goals and the first on-sky test results. We discuss several innovations that make this system a pathfinder for next generation AO systems. These include a unique woofer-tweeter control that provides full dynamic range correction from tip/tilt to 16 cycles, variable pupil sampling wavefront sensor, new enhanced silver coatings developed at UC Observatories that improve science and LGS throughput, and tight mechanical rigidity that enables a multi-hour diffraction- limited exposure in LGS mode for faint object spectroscopy science.

preprint2014arXiv

Swimming with ShARCS: Comparison of On-sky Sensitivity With Model Predictions for ShaneAO on the Lick Observatory 3-meter Telescope

The Lick Observatory's Shane 3-meter telescope has been upgraded with a new infrared instrument (ShARCS - Shane Adaptive optics infraRed Camera and Spectrograph) and dual-deformable mirror adaptive optics (AO) system (ShaneAO). We present first-light measurements of imaging sensitivity in the Ks band. We compare measured results to predicted signal-to-noise ratio and magnitude limits from modeling the emissivity and throughput of ShaneAO and ShARCS. The model was validated by comparing its results to the Keck telescope adaptive optics system model and then by estimating the sky background and limiting magnitudes for IRCAL, the previous infra-red detector on the Shane telescope, and comparing to measured, published results. We predict that the ShaneAO system will measure lower sky backgrounds and achieve 20\% higher throughput across the $JHK$ bands despite having more optical surfaces than the current system. It will enable imaging of fainter objects (by 1-2 magnitudes) and will be faster to reach a fiducial signal-to-noise ratio by a factor of 10-13. We highlight the improvements in performance over the previous AO system and its camera, IRCAL.