Source author record

Renate Kupke

Renate Kupke appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

Design of SCALES: A 2-5 Micron Coronagraphic Integral Field Spectrograph for Keck Observatory

We present the design of SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) a new 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. SCALES enables low-resolution (R~50) spectroscopy, as well as medium-resolution (R~4,000) spectroscopy with the goal of discovering and characterizing cold exoplanets that are brightest in the thermal infrared. Additionally, SCALES has a 12x12" field-of-view imager that will be used for general adaptive optics science at Keck. We present SCALES's specifications, its science case, its overall design, and simulations of its expected performance. Additionally, we present progress on procuring, fabricating and testing long lead-time components.

preprint2022arXiv

Fabrication of Pupil Masks for a New Infrared Exoplanet Imager at Keck Observatory

The Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy (SCALES) is an instrument being designed to perform direct imaging of exoplanets in the mid-infrared (2-5 μm) with the Adaptive Optics System of W.M. Keck Observatory. To eliminate unwanted thermal infrared radiation, SCALES utilizes both a cold stop for excluding background radiation and a vector vortex coronagraph with Lyot stops for starlight suppression. Optimal geometric masks have been designed. We simulate the propagation of light through the Lyot plane and analyze the on-axis images of stars in the K, L, and M band for the performance of the Lyot stops. Additionally, finalized cold stop and Lyot stop designs are presented along with evaluations on the effects of manufacturing tolerances and tilt in pupil planes caused by off-axis parabolic mirror relays.

preprint2022arXiv

Liger at Keck Observatory: Design of Imager Optical Assembly and Spectrograph Re-Imaging Optics

Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module and lenslet array. Each imager component and the first two RIO mechanisms are assembled and individually aligned on the same optical plate. Baffling suppresses background radiation and scattered light, and a pupil viewing camera allows the imager detector to focus on an image of the telescope pupil. The optical plate mounts on an adapter frame for alignment of the overall system. The imager and RIO will be characterized in a cryogenic test chamber before installation in the final science cryostat.

preprint2022arXiv

Liger at Keck Observatory: Design of the Data Reduction System and Software Interfaces

Liger is a second generation near-infrared imager and integral field spectrograph (IFS) for the W. M. Keck Observatory that will utilize the capabilities of the Keck All-sky Precision Adaptive-optics (KAPA) system. Liger operates at a wavelength range of 0.81 μm - 2.45 μm and utilizes a slicer and a lenslet array IFS with varying spatial plate scales and fields of view resulting in hundreds of modes available to the astronomer. Because of the high level of complexity in the raw data formats for the slicer and lenslet IFS modes, Liger must be designed in conjunction with a Data Reduction System (DRS) which will reduce data from the instrument in real-time and deliver science-ready data products to the observer. The DRS will reduce raw imager and IFS frames from the readout system and provide 2D and 3D data products via custom quick-look visualization tools suited to the presentation of IFS data. The DRS will provide the reduced data to the Keck Observatory Archive (KOA) and will be available to astronomers for offline post-processing of observer data. We present an initial design for the DRS and define the interfaces between observatory and instrument software systems.

preprint2022arXiv

Liger at Keck Observatory: Imager Detector and IFS Pick-off Mirror Assembly

Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 $μ$m with spectral resolving powers of R$\sim$4,000-10,000. Liger makes use of a sequential imager and spectrograph design allowing for simultaneous observations. There are two spectrograph modes: a lenslet with high spatial sampling of 14 and 31 mas, and a slicer with 75 and 150 mas sampling with an expanded field of view. Two pick-off mirrors near the imager detector direct light to these two IFS channels. We present the design and structural analysis for the imager detector and IFS pick-off mirror mounting assembly that will be used to align and maintain stability throughout its operation. A piezoelectric actuator will be used to step through $\rm3\,mm$ of travel during alignment of the instrument to determine the optimal focus for both the detector and pick-off mirrors which will be locked in place during normal operation. We will demonstrate that the design can withstand the required gravitational and shipping loads and can be aligned within the positioning tolerances for the optics.

preprint2022arXiv

SCALES for Keck: Optical Design

SCALES is a high-contrast, infrared coronagraphic imager and integral field spectrograph (IFS) to be deployed behind the W.M. Keck Observatory adaptive optics system. A reflective optical design allows diffraction-limited imaging over a large wavelength range (1.0 - 5.0 microns). A microlens array-based IFS coupled with a lenslet reformatter ("slenslit") allow spectroscopy at both low (R = 35 - 250) and moderate (R = 2000 - 6500) spectral resolutions. The large wavelength range, diffraction-limited performance, high contrast coronagraphy and cryogenic operation present a unique optical design challenge. We present the full SCALES optical design, including performance modeling and analysis and manufacturing.

preprint2022arXiv

Weighing Exo-Atmospheres: A novel mid-resolution spectral mode for SCALES

SCALES (Slicer Combined with an Array of Lenslets for Exoplanet Spectroscopy) is a 2 to 5 micron high-contrast lenslet-based Integral Field Spectrograph (IFS) designed to characterize exoplanets and their atmospheres. Like other lenslet-based IFSs, SCALES produces a short micro-spectrum of each lenslet's micro-pupil. We have developed an image slicer that sits behind the lenslet array and dissects and rearranges a subset of micro-pupils into a pseudo-slit. The combination lenslet array and slicer (or slenslit) allows SCALES to produce much longer spectra, thereby increasing the spectra resolution by over an order of magnitude and allowing for comparisons to atmospheric modeling at unprecedented resolution. This proceeding describes the design and performance of the slenslit.

preprint2014arXiv

Commissioning ShARCS: the Shane Adaptive optics infraRed Camera-Spectrograph for the Lick Observatory 3-m telescope

We describe the design and first-light early science performance of the Shane Adaptive optics infraRed Camera-Spectrograph (ShARCS) on Lick Observatory's 3-m Shane telescope. Designed to work with the new ShaneAO adaptive optics system, ShARCS is capable of high-efficiency, diffraction-limited imaging and low-dispersion grism spectroscopy in J, H, and K-bands. ShARCS uses a HAWAII-2RG infrared detector, giving high quantum efficiency (>80%) and Nyquist sampling the diffraction limit in all three wavelength bands. The ShARCS instrument is also equipped for linear polarimetry and is sensitive down to 650 nm to support future visible-light adaptive optics capability. We report on the early science data taken during commissioning.

preprint2014arXiv

Opto-Mechanical Design of ShaneAO: the Adaptive Optics System for the 3-meter Shane Telescope

A Cassegrain mounted adaptive optics instrument presents unique challenges for opto-mechanical design. The flexure and temperature tolerances for stability are tighter than those of seeing limited instruments. This criteria requires particular attention to material properties and mounting techniques. This paper addresses the mechanical designs developed to meet the optical functional requirements. One of the key considerations was to have gravitational deformations, which vary with telescope orientation, stay within the optical error budget, or ensure that we can compensate with a steering mirror by maintaining predictable elastic behavior. Here we look at several cases where deformation is predicted with finite element analysis and Hertzian deformation analysis and also tested. Techniques used to address thermal deformation compensation without the use of low CTE materials will also be discussed.

preprint2014arXiv

ShaneAO: wide science spectrum adaptive optics system for the Lick Observatory

A new high-order adaptive optics system is now being commissioned at the Lick Observatory Shane 3-meter telescope in California. This system uses a high return efficiency sodium beacon and a combination of low and high-order deformable mirrors to achieve diffraction-limited imaging over a wide spectrum of infrared science wavelengths covering 0.8 to 2.2 microns. We present the design performance goals and the first on-sky test results. We discuss several innovations that make this system a pathfinder for next generation AO systems. These include a unique woofer-tweeter control that provides full dynamic range correction from tip/tilt to 16 cycles, variable pupil sampling wavefront sensor, new enhanced silver coatings developed at UC Observatories that improve science and LGS throughput, and tight mechanical rigidity that enables a multi-hour diffraction- limited exposure in LGS mode for faint object spectroscopy science.

preprint2014arXiv

Swimming with ShARCS: Comparison of On-sky Sensitivity With Model Predictions for ShaneAO on the Lick Observatory 3-meter Telescope

The Lick Observatory's Shane 3-meter telescope has been upgraded with a new infrared instrument (ShARCS - Shane Adaptive optics infraRed Camera and Spectrograph) and dual-deformable mirror adaptive optics (AO) system (ShaneAO). We present first-light measurements of imaging sensitivity in the Ks band. We compare measured results to predicted signal-to-noise ratio and magnitude limits from modeling the emissivity and throughput of ShaneAO and ShARCS. The model was validated by comparing its results to the Keck telescope adaptive optics system model and then by estimating the sky background and limiting magnitudes for IRCAL, the previous infra-red detector on the Shane telescope, and comparing to measured, published results. We predict that the ShaneAO system will measure lower sky backgrounds and achieve 20\% higher throughput across the $JHK$ bands despite having more optical surfaces than the current system. It will enable imaging of fainter objects (by 1-2 magnitudes) and will be faster to reach a fiducial signal-to-noise ratio by a factor of 10-13. We highlight the improvements in performance over the previous AO system and its camera, IRCAL.

preprint2009arXiv

Integrated Laboratory Demonstrations of Multi-Object Adaptive Optics on a Simulated 10-Meter Telescope at Visible Wavelengths

One important frontier for astronomical adaptive optics (AO) involves methods such as Multi-Object AO and Multi-Conjugate AO that have the potential to give a significantly larger field of view than conventional AO techniques. A second key emphasis over the next decade will be to push astronomical AO to visible wavelengths. We have conducted the first laboratory simulations of wide-field, laser guide star adaptive optics at visible wavelengths on a 10-meter-class telescope. These experiments, utilizing the UCO/Lick Observatory's Multi-Object / Laser Tomography Adaptive Optics (MOAO/LTAO) testbed, demonstrate new techniques in wavefront sensing and control that are crucial to future on-sky MOAO systems. We (1) test and confirm the feasibility of highly accurate atmospheric tomography with laser guide stars, (2) demonstrate key innovations allowing open-loop operation of Shack-Hartmann wavefront sensors (with errors of ~30 nm) as will be needed for MOAO, and (3) build a complete error budget model describing system performance. The AO system maintains a performance of 32.4% Strehl on-axis, with 24.5% and 22.6% at 10" and 15", respectively, at a science wavelength of 710 nm (R-band) over the equivalent of 0.8 seconds of simulation. The MOAO-corrected field of view is ~25 times larger in area than that limited by anisoplanatism at R-band. Our error budget is composed of terms verified through independent, empirical experiments. Error terms arising from calibration inaccuracies and optical drift are comparable in magnitude to traditional terms like fitting error and tomographic error. This makes a strong case for implementing additional calibration facilities in future AO systems, including accelerometers on powered optics, 3D turbulators, telescope and LGS simulators, and external calibration ports for deformable mirrors.