Researcher profile

Robert Wagner

Robert Wagner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2016arXiv

Development and testing of cost-effective, 6 cm x 6 cm MCP-based photodetectors for fast timing applications

Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area picosecond photodetector (LAPPD) collaboration is developing new techniques for making large-area photodetectors based on new MCP fabrication and functionalization methods. A small single tube processing system (SmSTPS) was constructed at Argonne National Laboratory (ANL) for developing scalable, cost-effective, glass-body, 6 cm x 6 cm, picosecond photodetectors based on MCPs functionalized by Atomic Layer Deposition (ALD). Recently, a number of fully processed and hermitically sealed prototypes made of MCPs with 20 micron pores have been fabricated. This is a significant milestone for the LAPPD project. These prototypes were characterized with a pulsed laser test facility. Without optimization, the prototypes have shown excellent results: The time resolution is ~57 ps for single photoelectron mode and ~15 ps for multi-photoelectron mode; the best position resolution is < 0.8 mm for large pulses. In this paper, the tube processing system, the detector assembly, experimental setup, data analysis and the key performance will be presented.

preprint2016arXiv

MCP-based Photodetectors for Cryogenic Applications

The Argonne MCP-based photo detector is an offshoot of the Large Area Pico-second Photo Detector (LAPPD) project, wherein 6 cm x 6 cm sized detectors are made at Argonne National Laboratory. We have successfully built and tested our first detectors for pico-second timing and few mm spatial resolution. We discuss our efforts to customize these detectors to operate in a cryogenic environment. Initial plans aim to operate in liquid argon. We are also exploring ways to mitigate wave length shifting requirements and also developing bare-MCP photodetectors to operate in a gaseous cryogenic environment.

preprint2013arXiv

High Performance Photocathodes based on Molecular Beam Epitaxy Deposition for Next Generation Photo Detectors and Light Sources

The development of high-performance photocathodes is a key challenge for future accelerator and particle physics applications. In this paper photocathode growth through molecular beam epitaxy is introduced as a promising technique to obtain robust, highly efficient alkali-antimonide based photocathodes. Recent research shows that the quantum efficiency of photocathodes can be significantly enhanced through control of the photocathode crystallinity. Molecular beam epitaxy allows for cost-effective growth of large-area photocathodes with excellent control of the stoichiometry and crystallinity, making photocathodes with peak quantum efficiencies exceeding 35% routine.

preprint2012arXiv

Nonuniform current density and spin accumulation in a 1 μm thick n-GaAs channel

The spin accumulation in an n-GaAs channel produced by spin extraction into a (Ga,Mn)As contact is measured by cross-sectional imaging of the spin polarization in GaAs. The spin polarization is observed in a 1 \mum thick n-GaAs channel with the maximum polarization near the contact edge opposite to the maximum current density. The one-dimensional model of electron drift and spin diffusion frequently used cannot explain this observation. It also leads to incorrect spin lifetimes from Hanle curves with a strong bias and distance dependence. Numerical simulations based on a two-dimensional drift-diffusion model, however, reproduce the observed spin distribution quite well and lead to realistic spin lifetimes.

preprint2012arXiv

Very-high energy gamma-ray astronomy: A 23-year success story in high-energy astroparticle physics

Very-high energy (VHE) gamma quanta contribute only a minuscule fraction - below one per million - to the flux of cosmic rays. Nevertheless, being neutral particles they are currently the best &#34;messengers&#34; of processes from the relativistic/ultra-relativistic Universe because they can be extrapolated back to their origin. The window of VHE gamma rays was opened only in 1989 by the Whipple collaboration, reporting the observation of TeV gamma rays from the Crab nebula. After a slow start, this new field of research is now rapidly expanding with the discovery of more than 150 VHE gamma-ray emitting sources. Progress is intimately related with the steady improvement of detectors and rapidly increasing computing power. We give an overview of the early attempts before and around 1989 and the progress after the pioneering work of the Whipple collaboration. The main focus of this article is on the development of experimental techniques for Earth-bound gamma-ray detectors; consequently, more emphasis is given to those experiments that made an initial breakthrough rather than to the successors which often had and have a similar (sometimes even higher) scientific output as the pioneering experiments. The considered energy threshold is about 30 GeV. At lower energies, observations can presently only be performed with balloon or satellite-borne detectors. Irrespective of the stormy experimental progress, the success story could not have been called a success story without a broad scientific output. Therefore we conclude this article with a summary of the scientific rationales and main results achieved over the last two decades.

preprint2009arXiv

A conceptual design of an advanced 23 m diameter IACT of 50 tons for ground-based gamma-ray astronomy

A conceptual design of an advanced Imaging Air Cherenkov Telescope with a 23 m diameter mirror and of 50 tons weight will be presented. A system photon detection efficiency of 15-17%, averaged over 300-600 nm, is aimed at to lower the threshold to 10-20 GeV. Prospects for a second generation camera with Geiger-mode Avalanche Photo Diodes will be discussed.

preprint2009arXiv

Monitoring of Bright Blazars with MAGIC in the 2007/2008 Season

Because of the short duty-cycles and observation-time constraints, studies of bright TeV (E>100 GeV) blazars are mostly restricted to flaring episodes or rather short (days to few weeks) multiwavelength campaigns. At the same time, long-term studies of these objects are essential to gain a more complete understanding of the blazar phenomenon and to constrain theoretical models concerning jet physics. Only unbiased long-term studies are adequate for the determination of flaring state probabilities and for estimating the statistical significance of possible correlations between TeV flaring states and other wavebands or observables, such as neutrino events. Regular observations also provide triggers for multiwavelength ToO observations originating from the TeV waveband. These are particularly needed to identify and study orphan TeV flares, i.e. flares without counterparts in other wavebands. In 2007/8 the MAGIC telescope has monitored three TeV blazars on a regular basis: Mrk 501, Mrk 421, and 1ES 1959+650. We present preliminary results of these observations including the measured light curves and a correlation study for VHE gamma-rays and X-rays and VHE gamma-rays and optical R-band for Mrk 421.