Researcher profile

Rizwan Ahmad

Rizwan Ahmad contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2022arXiv

Denoising Generalized Expectation-Consistent Approximation for MR Image Recovery

To solve inverse problems, plug-and-play (PnP) methods replace the proximal step in a convex optimization algorithm with a call to an application-specific denoiser, often implemented using a deep neural network (DNN). Although such methods yield accurate solutions, they can be improved. For example, denoisers are usually designed/trained to remove white Gaussian noise, but the denoiser input error in PnP algorithms is usually far from white or Gaussian. Approximate message passing (AMP) methods provide white and Gaussian denoiser input error, but only when the forward operator is sufficiently random. In this work, for Fourier-based forward operators, we propose a PnP algorithm based on generalized expectation-consistent (GEC) approximation -- a close cousin of AMP -- that offers predictable error statistics at each iteration, as well as a new DNN denoiser that leverages those statistics. We apply our approach to magnetic resonance (MR) image recovery and demonstrate its advantages over existing PnP and AMP methods.

preprint2022arXiv

Expectation Consistent Plug-and-Play for MRI

For image recovery problems, plug-and-play (PnP) methods have been developed that replace the proximal step in an optimization algorithm with a call to an application-specific denoiser, often implemented using a deep neural network. Although such methods have been successful, they can be improved. For example, the denoiser is often trained using white Gaussian noise, while PnP's denoiser input error is often far from white and Gaussian, with statistics that are difficult to predict from iteration to iteration. PnP methods based on approximate message passing (AMP) are an exception, but only when the forward operator behaves like a large random matrix. In this work, we design a PnP method using the expectation consistent (EC) approximation algorithm, a generalization of AMP, that offers predictable error statistics at each iteration, from which a deep-net denoiser can be effectively trained.

preprint2022arXiv

Maximizing Unambiguous Velocity Range in Phase-contrast MRI with Multipoint Encoding

In phase-contrast magnetic resonance imaging (PC-MRI), the velocity of spins at a voxel is encoded in the image phase. The strength of the velocity encoding gradient offers a trade-off between the velocity-to-noise ratio (VNR) and the extent of phase aliasing. Phase differences provide invariance to an unknown background phase. Existing literature proposes processing a reduced set of phase difference equations, simplifying the phase unwrapping problem at the expense of VNR or unaliased range of velocities, or both. Here, we demonstrate that the fullest unambiguous range of velocities is a parallelepiped, which can be accessed by jointly processing all phase differences. The joint processing also minimizes the velocity-to-noise ratio. The simple understanding of the unambiguous parallelepiped provides the potential for analyzing new multi-point acquisitions for an enhanced range of unaliased velocities; two examples are given.

preprint2022arXiv

Technical Report (v1.0)--Pseudo-random Cartesian Sampling for Dynamic MRI

For an effective application of compressed sensing (CS), which exploits the underlying compressibility of an image, one of the requirements is that the undersampling artifact be incoherent (noise-like) in the sparsifying transform domain. For cardiovascular MRI (CMR), several pseudo-random sampling methods have been proposed that yield a high level of incoherence. In this technical report, we present a collection of five pseudo-random Cartesian sampling methods that can be applied to 2D cine and flow, 3D volumetric cine, and 4D flow imaging. Four out of the five presented methods yield fast computation for on-the-fly generation of the sampling mask, without the need to create and store pre-computed look-up tables. In addition, the sampling distribution is parameterized, providing control over the sampling density. For each sampling method in the report, (i) we briefly describe the methodology, (ii) list default values of the pertinent parameters, and (iii) provide a publicly available MATLAB implementation.

preprint2022arXiv

Venc Design and Velocity Estimation for Phase Contrast MRI

In phase-contrast magnetic resonance imaging (PC-MRI), spin velocity contributes to the phase measured at each voxel. Therefore, estimating velocity from potentially wrapped phase measurements is the task of solving a system of noisy congruence equations. We propose Phase Recovery from Multiple Wrapped Measurements (PRoM) as a fast, approximate maximum likelihood estimator of velocity from multi-coil data with possible amplitude attenuation due to dephasing. The estimator can recover the fullest possible extent of unambiguous velocities, which can greatly exceed twice the highest venc. The estimator uses all pairwise phase differences and the inherent correlations among them to minimize the estimation error. Correlations are directly estimated from multi-coil data without requiring knowledge of coil sensitivity maps, dephasing factors, or the actual per-voxel signal-to-noise ratio. Derivation of the estimator yields explicit probabilities of unwrapping errors and the probability distribution for the velocity estimate; this, in turn, allows for optimized design of the phase-encoded acquisition. These probabilities are also incorporated into spatial post-processing to further mitigate wrapping errors. Simulation, phantom, and in vivo results for three-point PC-MRI acquisitions validate the benefits of reduced estimation error, increased recovered velocity range, optimized acquisition, and fast computation. A phantom study at 1.5T demonstrates 48.5% decrease in root mean squared error using PRoM with post-processing versus a conventional "dual-venc" technique. Simulation and 3T in vivo results likewise demonstrate the proposed benefits.

preprint2020arXiv

Automatic Extraction and Sign Determination of Respiratory Signal in Real-time Cardiac Magnetic Resonance imaging

In real-time (RT) cardiac cine imaging, a stack of 2D slices is collected sequentially under free-breathing conditions. A complete heartbeat from each slice is then used for cardiac function quantification. The inter-slice respiratory mismatch can compromise accurate quantification of cardiac function. Methods based on principal components analysis (PCA) have been proposed to extract the respiratory signal from RT cardiac cine, but these methods cannot resolve the inter-slice sign ambiguity of the respiratory signal. In this work, we propose a fully automatic sign correction procedure based on the similarity of neighboring slices and correlation to the center-of-mass curve. The proposed method is evaluated in eleven volunteers, with ten slices per volunteer. The motion in a manually selected region-of-interest (ROI) is used as a reference. The results show that the extracted respiratory signal has a high, positive correlation with the reference in all cases. The qualitative assessment of images also shows that the proposed approach can accurately identify heartbeats, one from each slice, belonging to the same respiratory phase. This approach can improve cardiac function quantification for RT cine without manual intervention.

preprint2020arXiv

Convolutional Framework for Accelerated Magnetic Resonance Imaging

Magnetic Resonance Imaging (MRI) is a noninvasive imaging technique that provides exquisite soft-tissue contrast without using ionizing radiation. The clinical application of MRI may be limited by long data acquisition times; therefore, MR image reconstruction from highly undersampled k-space data has been an active area of research. Many works exploit rank deficiency in a Hankel data matrix to recover unobserved k-space samples; the resulting problem is non-convex, so the choice of numerical algorithm can significantly affect performance, computation, and memory. We present a simple, scalable approach called Convolutional Framework (CF). We demonstrate the feasibility and versatility of CF using measured data from 2D, 3D, and dynamic applications.

preprint2020arXiv

Free-breathing Cardiovascular MRI Using a Plug-and-Play Method with Learned Denoiser

Cardiac magnetic resonance imaging (CMR) is a noninvasive imaging modality that provides a comprehensive evaluation of the cardiovascular system. The clinical utility of CMR is hampered by long acquisition times, however. In this work, we propose and validate a plug-and-play (PnP) method for CMR reconstruction from undersampled multi-coil data. To fully exploit the rich image structure inherent in CMR, we pair the PnP framework with a deep learning (DL)-based denoiser that is trained using spatiotemporal patches from high-quality, breath-held cardiac cine images. The resulting "PnP-DL" method iterates over data consistency and denoising subroutines. We compare the reconstruction performance of PnP-DL to that of compressed sensing (CS) using eight breath-held and ten real-time (RT) free-breathing cardiac cine datasets. We find that, for breath-held datasets, PnP-DL offers more than one dB advantage over commonly used CS methods. For RT free-breathing datasets, where ground truth is not available, PnP-DL receives higher scores in qualitative evaluation. The results highlight the potential of PnP-DL to accelerate RT CMR.

preprint2020arXiv

OCMR (v1.0)--Open-Access Multi-Coil k-Space Dataset for Cardiovascular Magnetic Resonance Imaging

Cardiovascular MRI (CMR) is a non-invasive imaging modality that provides excellent soft-tissue contrast without the use of ionizing radiation. Physiological motions and limited speed of MRI data acquisition necessitate development of accelerated methods, which typically rely on undersampling. Recovering diagnostic quality CMR images from highly undersampled data has been an active area of research. Recently, several data acquisition and processing methods have been proposed to accelerate CMR. The availability of data to objectively evaluate and compare different reconstruction methods could expedite innovation and promote clinical translation of these methods. In this work, we introduce an open-access dataset, called OCMR, that provides multi-coil k-space data from 53 fully sampled and 212 prospectively undersampled cardiac cine series.

preprint2020arXiv

Soft Computing Techniques for Dependable Cyber-Physical Systems

Cyber-Physical Systems (CPS) allow us to manipulate objects in the physical world by providing a communication bridge between computation and actuation elements. In the current scheme of things, this sought-after control is marred by limitations inherent in the underlying communication network(s) as well as by the uncertainty found in the physical world. These limitations hamper fine-grained control of elements that may be separated by large-scale distances. In this regard, soft computing is an emerging paradigm that can help to overcome the vulnerabilities, and unreliability of CPS by using techniques including fuzzy systems, neural network, evolutionary computation, probabilistic reasoning and rough sets. In this paper, we present a comprehensive contemporary review of soft computing techniques for CPS dependability modeling, analysis, and improvement. This paper provides an overview of CPS applications, explores the foundations of dependability engineering, and highlights the potential role of soft computing techniques for CPS dependability with various case studies, while identifying common pitfalls and future directions. In addition, this paper provides a comprehensive survey on the use of various soft computing techniques for making CPS dependable.

preprint2019arXiv

Plug and play methods for magnetic resonance imaging (long version)

Magnetic Resonance Imaging (MRI) is a non-invasive diagnostic tool that provides excellent soft-tissue contrast without the use of ionizing radiation. Compared to other clinical imaging modalities (e.g., CT or ultrasound), however, the data acquisition process for MRI is inherently slow, which motivates undersampling and thus drives the need for accurate, efficient reconstruction methods from undersampled datasets. In this article, we describe the use of "plug-and-play" (PnP) algorithms for MRI image recovery. We first describe the linearly approximated inverse problem encountered in MRI. Then we review several PnP methods, where the unifying commonality is to iteratively call a denoising subroutine as one step of a larger optimization-inspired algorithm. Next, we describe how the result of the PnP method can be interpreted as a solution to an equilibrium equation, allowing convergence analysis from the equilibrium perspective. Finally, we present illustrative examples of PnP methods applied to MRI image recovery.