Source author record

Richard P. Mildren

Richard P. Mildren appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Absorptive laser threshold magnetometry: combining visible diamond Raman lasers and nitrogen-vacancy centres

We propose a high-sensitivity magnetometry scheme based on a diamond Raman laser with visible pump absorption by an ensemble of coherently microwave driven negatively charged nitrogen-vacancy centres (NV) in the same diamond crystal. The NV centres' absorption and emission are spin-dependent. We show how the varying absorption of the NV centres changes the Raman laser output. A shift in the diamond Raman laser threshold and output occurs with the external magnetic-field and microwave driving. We develop a theoretical framework including steady-state solutions to describe the effects of coherently driven NV centres in a diamond Raman laser. We discuss that such a laser working at the threshold can be employed for magnetic-field sensing. In contrast to previous studies on NV magnetometry with visible laser absorption, the laser threshold magnetometry method is expected to have low technical noise, due to low background light in the measurement signal. For magnetic-field sensing, we project a shot-noise limited DC sensitivity of a few $\mathrm{pT}/\sqrt{\mathrm{Hz}}$ in a well-calibrated cavity with realistic parameters. This sensor employs the broad visible absorption of NV centres and unlike previous laser threshold magnetometry proposals it does not rely on active NV centre lasing or an infrared laser medium at the specific wavelength of the NV centre's infrared absorption line.

preprint2020arXiv

Coherent Raman pulses with quantum-randomized polarization

We demonstrate the generation of coherent Stokes pulses with randomized linear-polarization in diamond, when the pump wave-vector and linear polarization were oriented along the $[110]$ and $[1\bar{1}0]$ axes respectively. In this configuration the excitation of multiple Raman modes produces isotropic gain, preventing the Stokes pulse from acquiring a deterministic orientation and is instead randomized by the zero-point motion of the crystal. Experimental polarization measurements were consistent with an independent, identical distribution with an estimated entropy rate of 6.67 bits per pulse.