Researcher profile

Richard Hall-Wilton

Richard Hall-Wilton contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Double-GEM based thermal neutron detector prototype

The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a $^{10}$B$_4$C layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of 3.14(10) %, agreeing within 2.7 $σ$ with the experimental and analytic detection efficiencies obtained by the detector when tested in a 41.8 meV thermal neutron beam. The detector is position sensitive, equipped with a 256+256 strip readout connected to resistive chains, and achieves a spatial resolution better than 3 mm. The gain stability over time was also measured with a fluctuation of about 0.2 %h$^{-1}$ of the signal amplitude. A simple data acquisition with only 5 electronic channels is sufficient to operate this detector.

preprint2022arXiv

Effect of substrate roughness and material selection on the microstructure of sputtering deposited boron carbide thin films

Amorphous boron carbide (B4C) thin films are by far the most popular form for the neutron converting layers in the 10B-based neutron detectors, which are a rising trend in detector technologies in response to the increasing scarcity and price of 3He, the standard material for neutron detection. The microstructure of the B4C films is closely related to the important properties, e.g. density and adhesion, for the converting layers, which eventually affect the detection efficiency and the long-term stability of the detectors. To study the influence from substrates of different roughness and materials, the B4C films were deposited on polished Si substrates with Al, Ti, and Cu buffer layers and unpolished Si, Al, Ti, and Cu substrates by direct current magnetron sputtering at a substrate temperature of 623 K. The tapered columnar grains and nodular defects, generally observed in SEM images, indicated a strong shadowing effect where voids were introduced around the grains. The change in the grain size did not show a direct dependence to the substrate roughness, acquired from the surface profile, nor to the mass density of the films, obtained from reflectivity patterns. However, films with non-uniform size of columnar grains were deposited on substrates with high skewness, leading to a drop of mass density from ~95 % down to ~70 % of tabulated bulk density. On the other hand, similar microstructures and mass density were obtained from the films deposited on Al, Ti, and Cu of different roughness and good adhesion were observed from cross-cut adhesion tests, showing the reliability of sputtering deposited B4C films on common structural materials in neutron detectors.

preprint2020arXiv

Vanadium-based neutron Beam Monitor

A prototype quasi-parasitic thermal neutron beam monitor based on isotropic neutron scattering from a thin natural vanadium foil and standard $^3$He proportional counters is conceptualized, designed, simulated, calibrated, and commissioned. The European Spallation Source designed to deliver the highest integrated neutron flux originating from a pulsed source is currently under construction in Lund, Sweden. The effort to investigate a vanadium-based neutron beam monitor was triggered by a list of requirements for Beam Monitors permanently placed in the ESS neutron beams in order to provide reliable monitoring at complex beamlines: low attenuation, linear response over a wide range of neutron fluxes, near to constant efficiency for neutron wavelengths in a range of 0.6-10 Å, calibration stability and the possibility to place the system in vacuum are all desirable characteristics. The scattering-based prototype, employing a natural vanadium foil and standard $^3$He proportional counters, was investigated at the V17 and V20 neutron beamlines of the Helmholtz-Zentrum in Berlin, Germany, in several different geometrical configurations of the $^3$He proportional counters around the foil. Response linearity is successfully demonstrated for foil thicknesses ranging from 0.04 mm to 3.15 mm. Attenuation lower than 1% for thermal neutrons is demonstrated for the 0.04 mm and 0.125 mm foils. The geometries used for the experiment were simulated allowing for absolute flux calibration and establishing the possible range of efficiencies for various designs of the prototype. The operational flux limits for the beam monitor prototype were established as a dependency of the background radiation and prototype geometry. The herein demonstrated prototype monitors can be employed for neutron fluxes ranging from $10^3-10^{10}$ n/s/cm$^2$.

preprint2020arXiv

Verification of He-3 proportional counters fast neutron sensitivity through a comparison with He-4 detectors

In the field of neutron scattering science, a large variety of instruments require detectors for thermal and cold neutrons. Helium-3 has been one of the main actors in thermal and cold neutron detection for many years. Nowadays neutron facilities around the world are pushing their technologies to increase the available flux delivered at the instruments, this enables a completely new science landscape. Complementary with the increasing available flux, a better signal-to-background ratio (S/B) enables to perform new types of measurements. To this aim, this manuscript re-examines the background sensitivity of today's "gold standard" neutron detection. Fast neutrons and gamma-rays are the main background species in neutron scattering experiments. The efficiency (sensitivity) of detecting fast neutrons, cosmic rays and gamma-rays, for a Helium-3-based detector is studied here through the comparison with Helium-4 counters. The comparison to Helium-4 allows to separate the thermal (and cold) neutron to the fast neutron contributions in Helium-3-based counters, which are otherwise entangled; verifying previous results from an indirect method. A relatively high sensitivity is found. Moreover, an estimate for the cosmic neutron fluence, also a source of background, at ground level at ESS is presented in this manuscript.

preprint2019arXiv

Evidence of fast neutron sensitivity for 3He detectors and comparison with Boron-10 based neutron detectors

The 3He-based neutron detectors are no longer the default solution for neutron scattering applications. Both the inability of fulfilling the requirements in performance, needed for the new instruments, and the shortage of 3He, drove a series of research programs aiming to find new technologies for neutron detection. The characteristics of the new detector technologies have been extensively tested to prove their effectiveness with respect to the state-of-the-art technology. Among these, the background rejection capability is crucial to determine. The signal-to-background ratio is strongly related to the performance figure-of-merit for most instruments. These are designed to exploit the high flux expected from the new high intensity neutron sources. Therefore, an inadequate background rejection could significantly affect the measurements, leading to detector saturation and misleading events. This is of particular importance for the kind of techniques in which the signals are rather weak. For the first time, the sensitivity of 3He detectors to fast neutrons, up to En = 10 MeV, has been estimated. Two independent measurements are presented: a direct calculation based on a subtraction method used to disentangle the thermal and the fast neutron contribution, while a further evidence is calculated indirectly through a comparison with the recently published data from a 10B-based detector. Both investigations give a characterization on the order of magnitude for the sensitivity. A set of simulations is presented as well in order to support and to validate the results of the measurements. A sensitivity of 4x10-3 is observed from the data. This is two orders of magnitude higher than that previously observed in 10B-based detectors.