Source author record

Richard G. Compton

Richard G. Compton appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2015arXiv

One electron oxygen reduction in room temperature ionic liquids: A comparative study of Butler-Volmer and Symmetric Marcus-Hush theories using microdisc electrodes

The voltammetry for the reduction of oxygen at a microdisc electrode is reported in two room temperature ionic liquids: 1-butyl-1-methylpyyrolidinium bis(trifluoromethylsulfonyl) imide ([Bmpyrr][NTf2]) and trihexyltetradecylphosphonium bis9trifluoromethylsulfonyl) imide ([P14,6,6,6][NTf2]) at 298 K. Simulated voltammograms using Butler-Volmer theory and Symmetric Marcus-Hush (SMH) theory were compared with experimental data. Butler-Volmer theory consistently provided experimental parameters with a higher level of certainty than SMH theory. A value of solvent reorganisation energy for oxygen reduction in ionic liquids was inferred for the first time as 0.4-0.5 eV, which is attributable to inner-sphere reorganisation with a negligible contribution from solvent reorganisation. The developed Butler-Volmer and Symmetric Marcus-Hush programs are also used to theoretically study the possibility of kinetically limited steady state currents, and to establish an approximate equivalence relationship between microdisc electrodes and spherical electrodes resting on a surface for steady state voltammetry for both Butler-Volmer and Symmetric Marcus-Hush theory.

preprint2014arXiv

Equality of diffusion-limited chronoamperometric currents to equal area spherical and cubic nanoparticles on a supporting electrode surface

We computationally investigate the chronoamperometric current response of spherical and cubic particles on a supporting insulating surface. By using the method of finite differences and random walk simulations, we can show that both systems exhibit identical responses on all time scales if their exposed surface areas are equal. This result enables a simple and computationally effcient method to treat certain spherical geometries in random walk based noise investigations.

preprint2014arXiv

Voltammetry at porous electrodes: A theoretical study

Theory is presented to simulate both chronoamperometry and cyclic voltammetry at porous electrodes fabricated by means of electro-deposition around spherical templates. A theoretical method to extract heterogeneous rate constants for quasireversible and irreversible systems is proposed by the approximation of decoupling of the diffusion within the porous electrode and of bulk diffusion to the electrode surface.

preprint2013arXiv

Double potential step chronoamperometry at a microband electrode: Theory and experiment

Numerical simulation is used to characterise double potential step chronoamperometry at a microband electrode for a simple redox process A + e- goes to B, under conditions of full support such that diffusion is the only active form of mass transport. The method is shown to be highly sensitive for the measurement of the diffusion coefficient of both A and B, and is applied to the one electron reduction of decamethylferrocene (DMFc), DMFc - e- goes to DMFc+, in the room temperature ionic liquid 1-propyl-3-methylimidazolium bistrifluoromethylsulfonylimide. Theory and experiment are seen to be in excellent agreement and the following values of the diffusion coefficients were measured at 298 K: D_(DMFc) = 2.50 x 10^(-7) cm^(2) s^(-1) and D_(DMFc+) = 9.50 x 10^(-8) cm^(2) s^(-1).

preprint2013arXiv

Dual Band Electrodes in Generator-Collector Mode: Simultaneous Measurement of Two Species

A computational model for the simulation of a double band collector-generator experiment is applied to the situation where two electrochemical reactions occur concurrently. It is shown that chronoamperometric measurements can be used to take advantage of differences in diffusion coefficients to measure the concentrations of both electroactive species simultaneously, by measuring the time at which the collection efficiency reaches a specific value. The separation of the electrodes is shown to not affect the sensitivity of the method (in terms of percentage changes in the measured time to reach the specified collection efficiency), but wider gaps can provide a greater range of (larger) absolute values of this characteristic time. It is also shown that measuring the time taken to reach smaller collection efficiencies can allow for the detection of smaller amounts of whichever species diffuses faster. The case of a system containing both ascorbic acid and opamine in water is used to exemplify the method, and it is shown that mole fractions of ascorbic acid between 0.055 and 0.96 can, in principle, be accurately measured.

preprint2013arXiv

Interdigitated ring electrodes: Theory and experiment

The oxidation of potassium ferrocyanide, K_4Fe(CN)_6, in aqueous solution under fully supported conditions is carried out at interdigitated band and ring electrode arrays, and compared to theoretical models developed to simulate the processes. Simulated data is found to fit well with experimental results using literature values of diffusion coefficients for Fe(CN)_6^(4-) and Fe(CN)_6^(3-). The theoretical models are used to compare responses from interdigitated band and ring arrays, and the size of ring array required to approximate the response to a linear band array is investigated. An equation is developed for the radius of ring required for a pair of electrodes in a ring array to give a result with 5% of a pair of electrodes in a band array. This equation is found to be independent of the scan rate used over six orders of magnitude.