Source author record

Renu Tripathi

Renu Tripathi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Spin Squeezing Induced Enhancement of Sensitivity of an Atomic Clock using Coherent Population Trapping

The coherent population trapping (CPT) effect is used for making compact atomic clocks. There are two types of CPT clocks: the one in which the Raman beams are applied continuously and the one in which two CPT pulses separated by a dark period are applied (Ramsey scheme). It is obvious that the technique of spin squeezing can only be applied to the Ramsey CPT clock to enhance the sensitivity. However, it is not apparent how to adapt to the CPT clock the protocols for the microwave clock using one-axis-twist squeezing (OATS), since the Ramsey CPT clock is not trivially equivalent to the Ramsey microwave clock. In this paper, we show explicitly how to adapt two protocols using OATS, namely the Schrödinger cat state protocol (SCSP) and the generalization thereof, and the echo squeezing protocol (ESP), to the CPT clock. The ESP magnifies the phase shift by a factor of the square-root of (N/e), while the SCSP magnifies the phase shift by a factor of N/2 , making it able to achieve a higher sensitivity in the presence of excess noise.

preprint2020arXiv

Light ellipticity and polarization angle dependence of magnetic resonances in rubidium vapor using amplitude-modulated light: Theoretical and experimental investigations

We report on experimental and theoretical investigations of the polarization dependence of magnetic resonance generated by synchronous optical pumping. Magnetic resonances with narrow linewidth are generated experimentally using a rubidium vapor cell with octade-cyltrichlorosilane (OTS) antirelaxation coating on inner walls. We studied the effect of light ellipticity on the amplitudes and widths of magnetic resonances by matching the light modulation frequency with 2 Ω_L (alignment) and Ω_L(orientation) in a Bell-Bloom interaction geometry, where Ω_L corresponds to the Larmor frequency. Both 2 Ω_L and \OmegaL resonance amplitudes showed a strong dependence on the light ellipticity. In addition, we showed that the duty cycle of light modulation changes the slope of amplitude variations in 2Ω_L and Ω_L resonances with light ellipticity. As a potential application, we showed that the difference between 2Ω_Land Ω_Lresonance amplitudes can be used for in situ measurement of light ellipticity. We also studied the dependence of 2Ω_L and Ω_L resonance amplitudes on the polarization angle of linearly polarized light. These amplitudes oscillate periodically with the polarization angle. We found this oscillatory behavior to be sensitive to the tilt in magnetic field direction from the polarization plane. Such a property could be used to realize a vector magnetometer. A density matrix based theoretical model is developed to simulate the magnetic resonance spectrum for different light polarizations. Our theoretical model accurately reproduces the above mentioned experimental observations.

preprint2020arXiv

Magnetometry using sodium fluorescence with synchronous modulation of two-photon resonant light fields

We report a new technique for generating magnetic resonance with synchronous modulation of two-photon resonant light fields. Magnetic resonances in fluorescence from a sodium cell are measured to demonstrate suitability of this technique for remote magnetometry. A strong magnetic resonance with its dip corresponding to the Larmor frequency is produced in the presence of a transverse magnetic field. An additional resonance at 3\{Omega_L} is observed, which can be used to determine the magnetic field orientation. We have developed a theoretical model based on the density matrix equations to verify our experimental observations. An average magnetic field sensitivity of 41 \mathbf{pT}/\sqrt{\mathbf{Hz}} is measured using light duty cycles ranging from 35% to 10%. We have discussed possible changes that can be made to improve the sensitivity of this scheme further.

preprint2019arXiv

Magneto-optical resonances in fluorescence from sodium D2 manifold

We report on magneto-optical resonances observed in sodium fluorescence from D2 manifold with an intensity modulated light. Fluorescence resonances are measured in the perpendicular and backward directions to the light propagation, in laboratory experiments using a sodium cell containing neon buffer gas. Properties of these resonances are studied by varying the magnetic field at fixed light modulation frequency, and vice-versa. Modulation with low-duty cycle shows higher-harmonic resonances of the modulation frequency and sub-harmonic resonances of the Larmor frequency. A dark resonance with maximum amplitude for laser wavelength closer to the crossover peak is observed. The origin of this dark resonance observed in Na D2 line is discussed using a theoretical model. Present study is aimed towards improving the understanding of magneto-optical resonances for remote magnetometry applications with mesospheric sodium.

preprint2014arXiv

Incorporation of Polar Mellin Transform in a Hybrid Optoelectronic Correlator for Scale & Rotation Invariant Target Recognition

In this paper, we show that our proposed hybrid optoelectronic correlator (HOC), which correlates images using spatial light modulators (SLM), detectors and field programmable gate arrays (FPGAs), is capable of detecting objects in a scale and rotation invariant manner, along with the shift invariance feature, by incorporating polar mellin transform (PMT). We also illustrate a key limitation of the ideas presented in previous papers on performing PMT and present a solution to circumvent this limitation by cutting out a small circle at the center of the Fourier Transform which precedes PMT. Furthermore, we show how to carry out shift, rotation and scale invariant detection of multiple matching objects simultaneously, a process previously thought to be incompatible with PMT based correlators. We present results of numerical simulations to validate the concepts.

preprint2013arXiv

Hybrid Optoelectronic Correlator Architecture for Shift Invariant Target Recognition

In this paper, we present theoretical details and the underlying architecture of a hybrid optoelectronic correlator that correlates images using Spatial Light Modulators (SLM), detector arrays and Field Programmable Gate Array (FPGA). The proposed architecture bypasses the need for nonlinear materials such as photorefractive polymer films by using detectors instead, and the phase information is yet conserved by the interference of plane waves with the images. However, the output of such a Hybrid Opto-electronic Correlator (HOC) has four terms: two convolution signals and two cross-correlation signals. By implementing a phase stabilization and scanning circuit, the convolution terms can be eliminated, so that the behavior of an HOC becomes essentially identical to that of a conventional holographic correlator (CHC). To achieve the ultimate speed of such a correlator, we also propose an opto-electronic chip which would perform all the electrical processes in a parallel manner. The HOC architecture along with the phase stabilization technique would thus be as good as a CHC, capable of high speed image recognition in a translation invariant manner.

preprint2010arXiv

A Close Companion Search around L Dwarfs using Aperture Masking Interferometry and Palomar Laser Guide Star Adaptive Optics

We present a close companion search around sixteen known early-L dwarfs using aperture masking interferometry with Palomar laser guide star adaptive optics. The use of aperture masking allows the detection of close binaries, corresponding to projected physical separations of 0.6-10.0 AU for the targets of our survey. This survey achieved median contrast limits of Delta_K ~ 2.3 for separations between 1.2 - 4 lambda/D, and Delta_K ~ 1.4 at (2/3)lambda/D. We present four candidate binaries detected with moderate to high confidence (90-98%). Two have projected physical separations less than 1.5 AU. This may indicate that tight-separation binaries contribute more significantly to the binary fraction than currently assumed, consistent with spectroscopic and photometric overluminosity studies. Ten targets of this survey have previously been observed with the Hubble Space Telescope as part of companion searches. We use the increased resolution of aperture masking to search for close or dim companions that would be obscured by full aperture imaging, finding two candidate binaries. This survey is the first application of aperture masking with laser guide star adaptive optics at Palomar. Several new techniques for the analysis of aperture masking data in the low signal to noise regime are explored.