Source author record

Renée Charrière

Renée Charrière appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Compact cold atom gravimeter for field applications

We present a cold atom gravimeter dedicated to field applications. Despite the compactness of our gravimeter, we obtain performances (sensitivity 42 microGal/Hz^0.5, accuracy 25 microGal) close to the bestgravimeters. We report gravity measurements in an elevator which led us to the determination of the Earth's gravity gradient with a precision of 4 E. These measurements in a non-laboratory environment demonstrate that our technology of gravimeter is enough compact, reliable and robust for field applications. Finally, we report gravity measurements in a moving elevator which open the way to absolute gravity measurements in an aircraft or a boat.

preprint2012arXiv

Phase shift in an atom interferometer induced by the additional laser lines of a Raman laser generated by modulation

The use of Raman laser generated by modulation for light-pulse atom interferometer allows to have a laser system more compact and robust. However, the additional laser frequencies generated can perturb the atom interferometer. In this article, we present a precise calculation of the phase shift induced by the additional laser frequencies. The model is validated by comparison with experimental measurements on an atom gravimeter. The uncertainty of the phase shift determination limits the accuracy of our compact gravimeter at 8.10^-8 m/s^2. We show that it is possible to reduce considerably this inaccuracy with a better control of experimental parameters or with particular interferometer configurations.

preprint2011arXiv

Local gravity measurement with the combination of atom interferometry and Bloch oscillations

We present a local measurement of gravity combining Bloch oscillations and atom interferometry. With a falling distance of 0.8 mm, we achieve a sensitivity of 2x10-7 g with an integration time of 300 s. No bias associated with the Bloch oscillations has been measured. A contrast decay with Bloch oscillations has been observed and attributed to the spatial quality of the laser beams. A simple experimental configuration has been adopted where a single retro-reflected laser beam is performing atoms launch, stimulated Raman transitions and Bloch oscillations. The combination of Bloch oscillations and atom interferometry can thus be realized with an apparatus no more complex than a standard atomic gravimeter.