Source author record

Raphaël Galicher

Raphaël Galicher appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2026arXiv

A practical guide to Digital Micro-mirror Devices (DMDs) for wavefront shaping

Digital micromirror devices have gained popularity in wavefront shaping, offering a high frame rate alternative to liquid crystal spatial light modulators. They are relatively inexpensive, offer high resolution, are easy to operate, and a single device can be used in a broad optical bandwidth. However, some technical drawbacks must be considered to achieve optimal performance. These issues, often undocumented by manufacturers, mostly stem from the device's original design for video projection applications. Herein, we present a guide to characterize and mitigate these effects. Our focus is on providing simple and practical solutions that can be easily incorporated into a typical wavefront shaping setup.

preprint2020arXiv

A Family of Phase Masks For Broadband Coronagraphy Example of the Wrapped Vortex Phase Mask Theory and Laboratory demonstration

Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight and transmit most of the planet light but the number of optics to align is not a practical solution for an instrument. Finally, vector phase masks can be used to detect faint sources close to bright stars but they require the use of high quality circular polarizers and as for the previous solution, this leads to a complex instrument with numerous optics to align and stabilize. We propose simple coronagraphs that need one scalar phase mask and one binary Lyot stop only providing high transmission for the planet light (>50%) and high attenuation of the starlight over a large spectral bandpass (~30%) and a 360 degree field-of-view. From mathematical considerations, we find a family of 2D-phase masks optimized for an unobscured pupil. One mask is an azimuthal wrapped vortex phase ramp. We probe its coronagraphic performance using numerical simulations and laboratory tests. From numerical simulations, we predict the wrapped vortex can attenuate the peak of the star image by a factor of 1e4 over a 29% bandpass and 1e5 over a 18% bandpass with transmission of more than 50% of the planet flux at ~4 lambda/D. We confirm these predictions in laboratory in visible light between 550nm and 870nm. We also obtain laboratory dark hole images in which exoplanets with fluxes that are 3e-8 times the host star flux could be detected at 3sigma. Taking advantage of a new technology for etching continuous 2D-functions, new type of masks can be easily manufactured opening new possibilities for broadband coronagraphy.

preprint2020arXiv

Comparing focal plane wavefront control techniques:\\Numerical simulations and laboratory experiments

Fewer than 1% of all exoplanets detected to date have been characterized on the basis of spectroscopic observations of their atmosphere. Unlike indirect methods, high-contrast imaging offers access to atmospheric signatures by separating the light of a faint off-axis source from that of its parent star. Forthcoming space facilities, such as WFIRST/LUVOIR/HabEX, are expected to use coronagraphic instruments capable of imaging and spectroscopy in order to understand the physical properties of remote worlds. The primary technological challenge that drives the design of these instruments involves the precision control of wavefront phase and amplitude errors. Several FPWS and control techniques have been proposed and demonstrated in laboratory to achieve the required accuracy. However, these techniques have never been tested and compared under the same laboratory conditions. This paper compares two of these techniques in a closed loop in visible light: the pair-wise (PW) associated with electric field conjugation (EFC) and self-coherent camera (SCC). We first ran numerical simulations to optimize PW wavefront sensing and to predict the performance of a coronagraphic instrument with PW associated to EFC wavefront control, assuming modeling errors for both PW and EFC. Then we implemented the techniques on a laboratory testbed. We introduced known aberrations into the system and compared the wavefront sensing using both PW and SCC. The speckle intensity in the coronagraphic image was then minimized using PW+EFC and SCC independently. We demonstrate that both SCC and PW+EFC can generate a dark hole in space-like conditions in a few iterations. Both techniques reach the current limitation of our laboratory bench and provide coronagraphic contrast levels of 5e-9 in a narrow spectral band (<0.25% bandwidth)

preprint2020arXiv

Increasing the raw contrast of VLT/SPHERE with the dark hole technique. I. Simulations and validation on the internal source

Context. Since 1995 and the first discovery of an exoplanet orbiting a main-sequence star, 4000 exoplanets have been discovered using several techniques. However, only a few of these exoplanets were detected through direct imaging. Indeed, the imaging of circumstellar environments requires high-contrast imaging facilities and accurate control of wavefront aberrations. Ground-based planet imagers such as VLT/SPHERE or Gemini/GPI have already demonstrated great performance. However, their limit of detection is hampered by suboptimal correction of aberrations unseen by adaptive optics (AO). Aims. Instead of focusing on the phase minimization of the pupil plane as in standard AO, we aim to directly minimize the stellar residual light in the SPHERE science camera behind the coronagraph to improve the contrast as close as possible to the inner working angle. Methods. We propose a dark hole (DH) strategy optimized for SPHERE. We used a numerical simulation to predict the global improvement of such a strategy on the overall performance of the instrument for different AO capabilities and particularly in the context of a SPHERE upgrade. Then, we tested our algorithm on the internal source with the AO in closed loop. Results. We demonstrate that our DH strategy can correct for aberrations of phase and amplitude. Moreover, this approach has the ability to strongly reduce the diffraction pattern induced by the telescope pupil and the coronagraph, unlike methods operating at the pupil plane. Our strategy enables us to reach a contrast of 5e-7 at 150 mas from the optical axis in a few minutes using the SPHERE internal source. This experiment establishes the grounds for implementing the algorithm on sky in the near future.

preprint2014arXiv

High-contrast imaging in polychromatic light with the self-coherent camera

Context. In the context of direct imaging of exoplanets, coronagraphs are commonly proposed to reach the required very high contrast levels. However, wavefront aberrations induce speckles in their focal plane and limit their performance. Aims. An active correction of these wavefront aberrations using a deformable mirror upstream of the coronagraph is mandatory. These aberrations need to be calibrated and focal-plane wavefront-sensing techniques in the science channel are being developed. One of these, the self-coherent camera, of which we present the latest laboratory results. Methods. We present here an enhancement of the method: we directly minimized the complex amplitude of the speckle field in the focal plane. Laboratory tests using a four-quadrant phase-mask coronagraph and a 32x32 actuator deformable mirror were conducted in monochromatic light and in polychromatic light for different bandwidths. Results. We obtain contrast levels in the focal plane in monochromatic light better than 3.10^-8 (RMS) in the 5 - 12 λ/D region for a correction of both phase and amplitude aberrations. In narrow bands (10 nm) the contrast level is 4.10^-8 (RMS) in the same region. Conclusions. The contrast level is currently limited by the amplitude aberrations on the bench. We identified several improvements that can be implemented to enhance the performance of our optical bench in monochromatic as well as in polychromatic light.

preprint2013arXiv

Independent confirmation of β Pictoris b imaging with NICI

Context. β Pictoris b is one of the most studied objects nowadays since it was identified with VLT/NaCo as a bona-fide exoplanet with a mass of about 9 times that of Jupiter at an orbital separation of 8-9 AU. The link between the planet and the dusty disk is unambiguously attested and this system provides an opportunity to study the disk/planet interactions and to constrain formation and evolutionary models of gas giant planets. Still, β Pictoris b had never been confirmed with other telescopes so far. Aims. We aimed at an independent confirmation using a different instrument. Methods. We retrieved archive images from Gemini South obtained with the instrument NICI, which is designed for high contrast imaging. The observations combine coronagraphy and angular differential imaging and were obtained at three epochs in Nov. 2008, Dec. 2009 and Dec. 2010. Results. We report the detection with NICI of the planet β Pictoris b in Dec. 2010 images at a separation of 404 \pm 10 mas and P A = 212.1 \pm 0.7° . It is the first time this planet is observed with a telescope different than the VLT.