Source author record

Rajendraprasad Bhattacharyay

Rajendraprasad Bhattacharyay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Development of Compact Multivariable Probe for Two-Phase Detection in PbLi-Argon Columns

Liquid gas two phase flow is a common occurrence in various industrial applications. For nuclear fusion applications with a Li based breeder, existence of two phase flow may lead to critical issues including decreased tritium breeding ratio, generation of hot spots and improper nuclear shielding. Additionally, a very large density ratio of liquid metal to gas mandates relevant experiments towards development and validation of software tools. PbLi has gained immense focus for its various advantages and is utilized in several breeding blanket concepts. In view of above mentioned requirements, a two phase detection tool is imperative for liquid PbLi environment. For liquid metal applications, electrical conductivity based probes are most suitable in terms of ruggedness, fabrication ease and operational simplicity. However, corrosive nature and high operational temperature for PbLi put severe demands on electrical insulation, a foremost requirement for electrical conductivity based schemes. In this study, a multivariable probe based on electrical conductivity and temperature measurement schemes is developed using Al2O3 coating as electrical insulation. Developed probe is validated in PbLi/Ar vertical column with bulk PbLi temperature upto 400 degC and time averaged void fraction upto 0.95 covering flow regimes from dispersed bubbly flow upto in box loss of coolant accident. Developed probe provides high reliability and excellent temporal resolution towards individual bubble detection through electrical conductivity based principle alongwith simultaneous two phase temperature trends. Present paper provides details about sensor probe fabrication, calibration, two phase test facility, void fraction estimations, bubble frequency and bubble residence time estimations alongwith critical observations from preliminary experimental investigations.

preprint2021arXiv

Development of Diagnostics for High-Temperature High-Pressure Liquid Pb-16Li Applications

Liquid lead-lithium (Pb-16Li) is of primary interest as one of the candidate materials for tritium breeder, neutron multiplier and coolant fluid in liquid metal blanket concepts relevant to fusion power plants. For an effective and reliable operation of such high temperature liquid metal systems, monitoring and control of critical process parameters is essential. However, limited operational experience coupled with high temperature operating conditions and corrosive nature of Pb-16Li severely limits application of commercially available diagnostic tools. This paper illustrates indigenous calibration test facility designs and experimental methods used to develop non-contact configuration level diagnostics using pulse radar level sensor, wetted configuration pressure diagnostics using diaphragm seal type pressure sensor and bulk temperature diagnostics with temperature profiling for high temperature, high pressure liquid Pb and Pb-16Li applications. Calibration check of these sensors was performed using analytical methods, at temperature between 380C-400C and pressure upto 1 MPa (g). Reliability and performance validation were achieved through long duration testing of sensors in liquid Pb and liquid Pb-16Li environment for over 1000 hour. Estimated deviation for radar level sensor lies within [-3.36 mm, +13.64 mm] and the estimated error for pressure sensor lies within 1.1% of calibrated span over the entire test duration. Results obtained and critical observations from these tests are presented in this paper.