Researcher profile

Raja Ayyanar

Raja Ayyanar contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

A SOCP-based ACOPF for Operational Scheduling of Three-phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters

The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution net-works, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. More-over, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effective-ness of the proposed ACOPF for unbalanced systems in provid-ing a global optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simu-lations show that the optimal settings result in a stable system

preprint2022arXiv

Optimal Placement of PV Smart Inverters with Volt-VAr Control in Electric Distribution Systems

The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capability for distribution systems with high photovoltaic (PV) penetration to mitigate voltage violation issues. The proposed optimization strategy enables a planningstage guide for upgrading the existing PV inverters to smart inverters with Volt-VAr capability while considering the operationstage characteristics of the Volt-VAr control. One advantage of this planning strategy is that it utilizes the local control capability of the smart inverter that requires no communication, thus avoiding issues related to communication delays and failures. Another advantage is that the Volt-VAr control characteristic is internally integrated into the optimization model as a set of constraints, making placement decisions more accurate. The objective of the optimization is to minimize the upgrading cost and the number of the smart inverters required while maintaining the voltage profile within the acceptable range. Case studies on an actual 12.47kV, 9km long Arizona utility feeder have been conducted using OpenDSS to validate the effectiveness of the proposed placement strategy in both static and dynamic simulations. Index Terms