Researcher profile

Mojdeh Khorsand

Mojdeh Khorsand contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

A Comprehensive Framework based on Dynamic and Steady State Analysis to Evaluate Power System Resiliency to Extreme Weather Conditions

Power system robustness against high impact low probability events is becoming a major concern. To depict distinct phases of a system response during these disturbances, an irregular polygon model is derived from the conventional trapezoid model and the model is analytically investigated for transmission system performance, based on which resiliency metrics are developed for the same. Furthermore, the system resiliency to windstorm is evaluated on the IEEE reliability test system (RTS) by performing steady state and dynamic security assessment incorporating protection modelling and corrective action schemes using the software Power System Simulator for Engineering (PSS/E). Based on the results of steady state and dynamic analysis, modified resiliency metrics are quantified. Finally, this paper quantifies the interdependency of operational and infrastructure resiliency as they cannot be considered as discrete characteristics of the system.

preprint2022arXiv

A Machine Learning-Based Method for Identifying Critical Distance Relays for Transient Stability Studies

Modeling protective relays is crucial for performing accurate stability studies as they play a critical role in defining the dynamic responses of power systems during disturbances. Nevertheless, due to the current limitations of stability software and the challenges of keeping track of the changes in the settings information of thousands of protective relays, modeling all the protective relays in bulk power systems is a challenging task. Distance relays are among the critical protection schemes, which are not properly modeled in current practices of stability studies. This paper proposes a machine learning-based method that uses the results of early-terminated stability studies to identify the critical distance relays required to be modeled in those studies. The algorithm used is the random forest (RF) classifier. GE positive sequence load flow analysis (PSLF) software is used to perform stability studies. The model is trained and tested on the Western Electricity Coordinating Council (WECC) system data representing the 2018 summer peak load under different operating conditions and topologies of the system. The results show the great performance of the method in identifying the critical distance relays. The results also show that only modeling the identified critical distance relays suffices to perform accurate stability studies.

preprint2022arXiv

A SOCP-based ACOPF for Operational Scheduling of Three-phase Unbalanced Distribution Systems and Coordination of PV Smart Inverters

The proliferation of distributed energy resources (DERs) im-poses new challenges to distribution system operation, e.g., power quality issues. To overcome these challenges and enhance system operation, it is critical to effectively utilize all available resources and accurately characterize unbalanced distribution networks in operational tools. This paper proposes a convex second-order-cone programming (SOCP)-based AC optimal power flow (ACOPF) model for three-phase unbalanced distribution net-works, including smart inverters and Volt-VAr controller (VVC) devices. Reactive power-voltage (Q-V) characteristics of smart inverters of solar photovoltaic (PV) units are also modeled. More-over, the settings of Q-V characteristics of VVC are co-optimized within the proposed ACOPF, considering the allowable range of the IEEE 1547-2018 standard. Furthermore, dynamic analyses are conducted to verify the stability of optimal settings of VVC. The proposed models are tested on an actual 1747-node primary distribution feeder in Arizona. The results illustrate the effective-ness of the proposed ACOPF for unbalanced systems in provid-ing a global optimal solution while capturing the non-linearity and non-convexity of ACOPF. By co-optimizing settings, system operation is improved due to the flexibility of adjusting reactive power output from PV units with VVC. The time-domain simu-lations show that the optimal settings result in a stable system

preprint2022arXiv

Optimal Placement of PV Smart Inverters with Volt-VAr Control in Electric Distribution Systems

The high R/X ratio of typical distribution systems makes the system voltage vulnerable to the active power injection from distributed energy resources (DERs). Moreover, the intermittent and uncertain nature of the DER generation brings new challenges to the voltage control. This paper proposes a two-stage stochastic optimization strategy to optimally place the PV smart inverters with Volt-VAr capability for distribution systems with high photovoltaic (PV) penetration to mitigate voltage violation issues. The proposed optimization strategy enables a planningstage guide for upgrading the existing PV inverters to smart inverters with Volt-VAr capability while considering the operationstage characteristics of the Volt-VAr control. One advantage of this planning strategy is that it utilizes the local control capability of the smart inverter that requires no communication, thus avoiding issues related to communication delays and failures. Another advantage is that the Volt-VAr control characteristic is internally integrated into the optimization model as a set of constraints, making placement decisions more accurate. The objective of the optimization is to minimize the upgrading cost and the number of the smart inverters required while maintaining the voltage profile within the acceptable range. Case studies on an actual 12.47kV, 9km long Arizona utility feeder have been conducted using OpenDSS to validate the effectiveness of the proposed placement strategy in both static and dynamic simulations. Index Terms

preprint2021arXiv

Real-Time Topology Detection and State Estimation in Distribution Systems Using Micro-PMU and Smart Meter Data

Distribution network topology detection and state estimation in real-time are critical for modern distribution systems management and control. However, number of sensors in distribution networks are limited and communication links between switch devices and distribution management system are not well-established. In this regard, this paper proposes mixed-integer quadratic programming (MIQP) formulations to determine the topology of distribution network and estimate distribution system states simultaneously using micro-phasor measurement units (micro-PMUs) and smart meter data. Two approaches based on AC optimal power flow are proposed and analyzed: (i) polar power-voltage (PPV) formulation, and (ii) rectangular current-voltage (RIV) formulation. The proposed models include convex objective function while constraints are linearized using first-order approximation of Taylor series and Big M method. The proposed models can identify multiple simultaneous switching actions at each time instant and different topology configurations including radial and meshed networks. Only measurement data at each time interval is needed to identify topology and states of the system correctly. The proposed models are tested on a modified IEEE-33 bus system with realistic load data from Pecan Street Inc. database. The results confirm that both models can identify system topology and states with remarkable accuracy in real-time, while RIV model outperforms PPV model.

preprint2020arXiv

Representation of Uncertainty in Electric Energy Market Models: Pricing Implication and Formulation

Modern market management systems continue to evolve due to the intentions to improve system security and reliability. This evolvement has been leading to a transition of market auction models from a deterministic structure with approximations on the reliability criteria (e.g., acquirement of contingency reserve through proxy reserve policies) to explicit representation of contingencies (e.g., estimation of post-contingency states via participation factors and stochastic programming). This paper proposes a comprehensive framework to establish various procedures for evaluating: (i) transparency and incentive compatibility of different contingency modeling approaches, and (ii) efficiency of two possible stochastic market designs. First, the concept of securitized LMP is presented to solve the issue of how market participants should be compensated for providing N-1 reliability services. Then, pricing implications and settlements of three market models are compared: (i) a deterministic market model with proxy serve policies, (ii) state-of-the-art market models with estimated post-contingency states, and (iii) a two-stage stochastic market model. Second, this paper evaluates two stochastic market models while accounting for potential adjustments from day-ahead scheduling to real-time operation: (i) minimizing expected operating cost of all N-1 scenarios, and (ii) minimizing the base-case (or no contingency) cost. These analyses are conducted on IEEE 118-bus test system.

preprint2020arXiv

Two-Stage Distributed Energy Resources Scheduling via Chance-Constrained AC Optimal Power Flow: A Second-Order Cone Programming Approach

The penetration of distributed energy resources (DERs) is increasing dramatically. Due to the uncertainty of DERs, the operation of the distribution system is facing higher risks and challenges. To overcome such challenges, a two-stage chance-constrained convex AC optimal power flow (ACOPF) model is proposed in this paper, which can increase the economic efficiency of distribution system operation and manage the intermittency of DERs. In the first stage, a convex second-order cone programming (SOCP)-based ACOPF model is proposed in which the detailed models and limitations of DER, namely, demand response (DR), energy storage units, and rooftop PV systems are modeled to obtain participation ratio of DERs. In the second stage, Monte Carlo simulation is utilized to model the uncertainties of DERs. A probability violation index is introduced to make a trade-off between scheduling more DERs and imposing a higher risk to the distribution system. In this stage, power flow analysis is conducted for each scenario to determine the probability violation index of system. Then, a modified SOCP-based ACOPF is proposed to satisfy the system probability violation criterion. Simulation results illustrate that the proposed two-stage chance-constrained model improves economic efficiency and reliability of real-time operation of the distribution system.