Source author record

Raj Ganesh Pala

Raj Ganesh Pala appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2026arXiv

CR-39 track detector signatures of slow neutron like signals in Heavy-water electrolysis

We report reproducible track-detector signals consistent with slow neutron capture events, recorded in D$_2$O electrolysis involving D-Pd deposited on Pt cathode. Sensitivity to slow neutrons was achieved using boron-coated CR-39 (BCR) detectors, which register charged particle tracks arising from the $^{10}$B$(n,α)^{7}$Li reaction. These detectors were positioned adjacent to identically prepared uncoated CR-39 control detectors (CCR), which are effectively insensitive to slow neutrons and serve to quantify background contributions from charged particles and fast neutrons under the present experimental conditions. A reproducible differential detector signature (BCR $>$ CCR) would thus indicative of slow neutron fluences. Across multiple independent D$_2$O electrolysis experiments in $0.25~\mathrm{T}$ field, the BCR exhibited significantly excess track signals relative to CCRs. Under these conditions, the observed differential response corresponds to an inferred detector-equivalent slow neutron flux of approximately $(6.7 \pm 0.2)~\mathrm{cm^{-2},s^{-1}}$. Removal of the magnetic field resulted in a reduction of the differential signal by a factor of $\sim6$, indicating a strong empirical dependence on the applied field. In contrast, H$_2$O electrolysis performed under otherwise identical conditions produced no measurable differential detector response, establishing the necessity of deuterated electrochemical conditions for the observed effect. The results are reported strictly as detector signatures consistent with slow neutron capture and do not assert any theoretical explanation. Instead, this work establishes a control verified and detector validated experimental protocol for detecting low flux slow neutrons, and provides empirical constraints relevant to slow neutron studies in experiments involving metal-deuteride systems.