Source author record

R. R. Shinde

R. R. Shinde appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

preprint2016arXiv

Design, development and performance study of six-gap glass MRPC detectors

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the interior plates are left electrically floating. The presence of multiple narrow sub--gaps with high electric field results in faster signals on the outer electrodes, thus improving the detector's time resolution. Due to their excellent performance and relatively low cost, the MRPC detector has found potential application in Time-of-Flight (TOF) systems. Here we present the design, fabrication, optimization of the operating parameters such as the HV, the gas mixture composition, and, performance of six--gap glass MRPC detectors of area 27cm $\times$ 27 cm, which are developed in order to find application as trigger detectors, in TOF measurement etc. The design has been optimized with unique spacers and blockers to ensure a proper gas flow through the narrow sub-gaps, which are 250 $μ$m wide. The gas mixture consisting of R134A, Isobutane and SF$_{6}$, and the fraction of each constituting gases has been optimized after studying the MRPC performance for a set of different concentrations. The counting efficiency of the MRPC is about 95% at $17.9$ kV. At the same operating voltage, the time resolution, after correcting for the walk effect, is found to be about $219$ ps.