Source author record

R. F. Neumann

R. F. Neumann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Two dimensional, electronic particle tracking in liquids with a graphene-based magnetic sensor array

The investigation of liquid flow at the nanoscale is a key area of applied research with high relevance to Physics, Chemistry and Biology. We introduce a method and a device that allows to spatially resolve liquid flow by integrating an array of graphene-based magnetic sensors used for tracking the movement of magnetic nanoparticles in the liquid under investigation. With a novel device conception based on standard integration processes and experimentally verified material parameters, we simulate the performance of a single sensor pixel, as well as the whole array, for tracking magnetic nanoparticles. The results demonstrate the ability (a) to detect individual nanoparticles in the liquid and (b) to reconstruct particle trajectories across the sensor array as a function of time, in what we call "Magnetic Nanoparticle Velocimetry" technique. Being a non-optical detection method, potential applications include particle tracking and flow analysis in opaque media at sub-micron scales.

preprint2015arXiv

Tailoring the nucleation of domain walls along multi-segmented cylindrical nanoelements

The magnetization reversal of three-segment cylindrical nanoelements comprising of alternating nanowire and nanotube sections is investigated by means of Monte Carlo simulations. Such nanoelements may feature a three-state behaviour with an intermediate plateau in the hysteresis curve due to a metastable pinning of the domain walls at the wire-tube interfaces. It turns out that vortex as well as transverse domain walls contribute to the magnetization reversal. By varying the geometric parameters, the sequence, or the material of the elements the nucleation location of domain walls, as well as their nucleation field, can be tailored. Especially interesting is the novel possibility to drive domain walls coherently in the same or in opposite directions by changing the geometry of the hybrid nanoelement. This important feature adds additional flexibility to the construction of logical devices based on domain wall movement. Another prominent outcome is that domain walls can be nucleated near the centre of the element and then traverse to the outer tips of the cylindrical structure when the applied field is increased, which also opens the possibility to use these three-segment nanoelements for the field induced delivery of domain walls as substitutes for large nucleation pads.

preprint2014arXiv

Quantitative $μ$PIV Measurements of Velocity Profiles

In Microscopic Particle Image Velocimetry ($μ$PIV), velocity fields in microchannels are sampled over finite volumes within which the velocity fields themselves may vary significantly. In the past, this has limited measurements often to be only qualitative in nature, blind to velocity magnitudes. In the pursuit of quantitatively useful results, one has treated the effects of the finite volume as errors that must be corrected by means of ever more complicated processing techniques. Resulting measurements have limited robustness and require convoluted efforts to understand measurement uncertainties. To increase the simplicity and utility of $μ$PIV measurements, we introduce a straightforward method, based directly on measurement, by which one can determine the size and shape of the volume over which moving fluids are sampled. By comparing measurements with simulation, we verify that this method enables quantitative measurement of velocity profiles across entire channels, as well as an understanding of experimental uncertainties. We show how the method permits measurement of an unknown flow rate through a channel of known geometry. We demonstrate the method to be robust against common sources of experimental uncertainty. We also apply the theory to model the technique of Scanning $μ$PIV, which is often used to locate the center of a channel, and we show how and why it can in fact misidentify the center. The results have general implications for research and development that requires reliable, quantitative measurement of fluid flow on the micrometer scale and below.

preprint2013arXiv

Magnetic properties of La(0.67)Sr(0.33)MnO3/BiFeO3(001) heterojunctions: chemically abrupt versus atomic intermixed interface

Using first-principles density-functional calculations, we address the magnetic properties of the ferromagnet/antiferromagnet La(0.67)Sr(0.33)MnO3/BiFeO3(001) heterojunctions, and investigate possible driving mechanisms for a ferromagnetic (FM) interfacial ordering of the Fe spins recently observed experimentally. We find that the chemically abrupt defect-free La(0.67)Sr(0.33)MnO3/BiFeO3(001) heterojunction displays, as ground state, an ordering with compensated Fe spins. Cation Fe/Mn intermixing at the interface tends to favour, instead, a FM interfacial order of the Fe spins, coupled antiferromagnetically to the bulk La(0.67)Sr(0.33)MnO3 spins, as observed experimentally. Such trends are understood based on a model description of the energetics of the exchange interactions.

preprint2013arXiv

Morphology and magnetism of multifunctional nanostructured $γ$-Fe$_2$O$_3$ films: Simulation and experiments

This paper introduces a new approach for simulating magnetic properties of nanocomposites comprising magnetic particles embedded in a non-magnetic matrix, taking into account the 3D structure of the system in which particles' positions correctly mimic real samples. The proposed approach develops a multistage simulation procedure in which the size and distribution of particles within the hosting matrix is firstly attained by means of the Cell Dynamic System (CDS) model. The 3D structure provided by the CDS step is further employed in a Monte Carlo (MC) simulation of zero-field-cooled/field-cooled (ZFC/FC) and magnetic hysteresis loops ($M \times H$ curves) for the system. Simulations are aimed to draw a realistic picture of the as-produced ultra-thin films comprising maghemite nanoparticles dispersed in polyaniline. Comparison (ZFC/FC and $M \times H$ curves) between experiments and simulations regarding the maximum of the ZFC curve ($T_{\scriptsize MAX}$), remanence ($M_R/M_s$) and coercivity ($H_C$) revealed the great accuracy of the multistage approach proposed here while providing information about the system's morphology and magnetic properties. For a typical sample the value we found experimentally for $T_{\scriptsize MAX}$ (54 K) was very close to the value provided by the simulation (53 K). For the parameters depending on the nanoparticle clustering the experimental values were consistently lower ($M_R/M_s$ = 0.32 and $H_C$ = 210 Oe) than the values we found in the simulation ($M_R/M_s$ = 0.53 and $H_C$ = 274 Oe). Indeed, the approach introduced here is very promising for the design of real magnetic nanocomposite samples with optimized features.

preprint2011arXiv

Stability of magnetic nanoparticles inside ferromagnetic nanotubes

During the last years great attention has been given to the encapsulation of magnetic nanoparticles. In this work we investigated the stability of small magnetic particles inside magnetic nanotubes. Multisegmented nanotubes were tested in order to optimize the stability of the particle inside the nanotubes. Our results evidenced that multisegmented nanotubes are more efficient to entrap the particles at temperatures up to hundreds of kelvins.