Source author record

R. E. Pywell

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
5topics
4close collaborators

Published work

3 publications

preprint2022arXiv

Proton Compton Scattering from Linearly Polarized Gamma Rays

Differential cross sections for Compton scattering from the proton have been measured at scattering angles of 55∘55^\circ, 90∘90^\circ, and 125∘125^\circ in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a weighted mean energy value of 83.4\,MeV (81.3\,MeV). These measurements were performed at the High Intensity Gamma-Ray Source facility at the Triangle Universities Nuclear Laboratory. The results are compared to previous measurements and are interpreted in the chiral effective field theory framework to extract the electromagnetic dipole polarizabilities of the proton, which gives αE1p=13.8±1.2stat±0.1BSR±0.3theo,βM1p=0.2∓1.2stat±0.1BSR∓0.3theoα_{E1}^p = 13.8\pm1.2_{\rm stat}\pm0.1_{\rm BSR}\pm0.3_{\rm theo}, β_{M1}^p = 0.2\mp1.2_{\rm stat}\pm0.1_{\rm BSR}\mp0.3_{\rm theo} in units of 10−4^{-4}\, fm3^3.

preprint2020arXiv

Compton scattering from 4^4He at the TUNL HIγγS facility

Differential cross sections for elastic Compton scattering from 4^4He have been measured with high statistical precision at the High Intensity γγ-ray Source at laboratory scattering angles of 55∘55^\circ, 90∘90^\circ, and 125∘125^\circ using a quasi-monoenergetic photon beam with a weighted mean energy value of 81.381.3 MeV. The results are compared to previous measurements and similar fore-aft asymmetry in the angular distribution of the differential cross sections is observed. This experimental work is expected to strongly motivate the development of effective-field-theory calculations of Compton scattering from 4^4He to fully interpret the data.

preprint2013arXiv

Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory

Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory have been investigated using the novel approach of Monte Carlo simulation. Results are compared to analytical calculations as well as experimental data for both specialized testing and production running to demonstrate a thorough understanding of the behavior of the detector system.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.