Researcher profile

R. C. Haight

R. C. Haight contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2019arXiv

Prompt Fission Neutrons in the $^{239}$Pu($n,f$) Reaction

Prompt fission neutron spectra from $^{239}$Pu($n,f$) were measured for incident neutron energies from $0.7$ to $700\,$MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center. A newly designed high-efficiency fission chamber was coupled to the highly segmented Chi-Nu array to detect neutrons emitted in fission events. The double time-of-flight technique was used to deduce the incident-neutron energies from the spallation target and the outgoing-neutron energies from the fission chamber. Prompt fission neutron spectra (PFNS) were measured with respect to $^{252}$Cf spontaneous fission down to $200\,$keV and up to about $12\,$MeV for all the incident neutron energies with typical uncertainties well below $2\%$ up to about $10\,$MeV outgoing-neutron energy. The general trend of PFNS is well reproduced by JEFF3.3 and ENDF-B\VIII.0 evaluations. Discrepancies were however observed for the low-energy part of the spectra, where evaluations overestimate the number of emitted neutrons. Neutron multiplicities and average kinetic energies as a function of incident-neutron energy are obtained experimentally with reported uncertainties below $0.4\%$. Neutron multiplicities disagree with some older datasets above $6\,$ MeV, indicating the need of using a high-efficiency fission detector, which does not bias the data. The measured mean kinetic energies agree with the most recent data. Evaluations fairly reproduce the trend, but fail to reproduce the experimental values within their uncertainties.

preprint2013arXiv

A 4p BaF2 detector for (n,g) cross section measurements at a spallation neutron source

The quest for improved neutron capture cross sections for advanced reactor concepts, transmutation of radioactive wastes as well as for astrophysical scenarios of neutron capture nucleosynthesis has motivated new experimental efforts based on modern techniques. Recent measurements in the keV region have shown that a 4p BaF2 detector represents an accurate and versatile instrument for such studies. The present work deals with the potential of such a 4p BaF2 detector in combination with spallation neutron sources, which offer large neutron fluxes over a wide energy range. Detailed Monte Carlo simulations with the GEANT package have been performed to investigate the critical backgrounds at a spallation facility, to optimize the detector design, and to discuss alternative solutions.

preprint2013arXiv

Background identification and suppression for the measurement of (n,g) reactions with the DANCE array at LANSCE

In the commissioning phase of the DANCE project (Detector for Advanced Neutron Capture Experiments) measurements have been performed with special emphasis on the identification and suppression of possible backgrounds for the planned (n,g) experiments. This report describes several background sources, observed in the experiment or anticipated from simulations, which will need to be suppressed in this and in similar detectors that are planned at other facilities. First successes are documented in the suppression of background from scattered neutrons captured in the detector as well as from the internal radiation. Experimental results and simulations using the GEANT code are compared.

preprint2009arXiv

The 14C(n,g) cross section between 10 keV and 1 MeV

The neutron capture cross section of 14C is of relevance for several nucleosynthesis scenarios such as inhomogeneous Big Bang models, neutron induced CNO cycles, and neutrino driven wind models for the r process. The 14C(n,g) reaction is also important for the validation of the Coulomb dissociation method, where the (n,g) cross section can be indirectly obtained via the time-reversed process. So far, the example of 14C is the only case with neutrons where both, direct measurement and indirect Coulomb dissociation, have been applied. Unfortunately, the interpretation is obscured by discrepancies between several experiments and theory. Therefore, we report on new direct measurements of the 14C(n,g) reaction with neutron energies ranging from 20 to 800 keV.

preprint2004arXiv

GEANT simulations of neutron capture experiments with a 4p BaF2 detector

The goal of this research project is to give quantitative information useful for the design of a g-ray detector to investigate neutron capture (n, g) reactions on radioactive nuclei at the Manuel Lujan Jr. Neutron Scattering Center (MLNSC) moderated neutron source at LANSCE. Data for neutron energies from thermal up to approximately 500 keV are desired. The radioactive nuclei can have half-lives as short as a few months. With the sample sizes foreseen, typically 1 mg, the radioactive decay rate can exceed tens of Curies (Ci).

preprint2004arXiv

Neutron capture measurements at a RIA-type facility

Neutron capture cross sections of unstable isotopes are important for neutron induced nucleosynthesis as well as for technological applications. The Rare Isotope Accelerator (RIA) or comparable facilities will be able to produce radioactive ion beams up to 10**12 particles/s and would therefore be a suitable place for (n,g) studies on radioactive isotopes with half-lives between days and months. We propose a facility for measurements of (n,g) cross sections of unstable isotopes in the keV range suited for minimal sample masses down to 10**15 atoms, corresponding to minimum half-lives of only 10 d.