Researcher profile

R. Bertoni

R. Bertoni contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Detection of low-energy X-rays with 1/2 and 1 inch LaBr3:Ce crystals read by SIPM arrays

LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm $^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution,good detector linearity and fast time response for low-energy X-rays. The study was triggered by the FAMU experiment at the RIKEN-RAL muon facility, aiming at a precise measurement of the proton Zemach radius to solve the so-called "proton radius puzzle". The goal is the detection of characteristic X-rays around 130 KeV. Other applications may be foreseen for homeland security and $γ$-ray astronomy. Results were obtained with a direct readout based on a CAEN V1730 FADC, with no need for an amplification stage. At the Cs$^{137}$ peak, energy resolutions up to $\sim 3 \%$ were obtained, using a readout with Hamamatsu SiPM arrays. These results compare well with best available results obtained with a PMT readout.

preprint2020arXiv

Ce:LaBr$_3$ crystals with SiPM array readout and temperature control for the FAMU experiment at RAL

Compact X-rays detectors made of 1/2 inch Ce:LaBr3 crystals of cubic shape with SiPM array readout have been developed for the FAMUexperiment at RIKEN-RAL, to instrument regions of difficult access. Due to the high photon yield of Ce:LaBr3 it was possible to use a simple readout scheme based on CAEN V1730 digitizers, without a dedicated amplification stage. The drift with temperature of SiPM gain was corrected by using CAEN A7885D regulated power supply chips with temperature feedback. Energy resolutions (FWHM) around 3:5% at the 137Cs peak and around 9% at the 57Co peak were obtained.

preprint2020arXiv

First measurement of the temperature dependence of muon transfer rate from muonic hydrogen atoms to oxygen

We report the first measurement of the temperature dependence of muon transfer rate from $μ$p atoms to oxygen between 100 and 300 K. Data were obtained from the X-ray spectra of delayed events in gaseous target H$_2$/O$_2$ exposed to a muon beam. Based on the data, we determined the muon transfer energy dependence up to 0.1 eV, showing an 8-fold increase in contrast with the predictions of constant rate in the low energy limit. This work set constraints on theoretical models of muon transfer, and is of fundamental importance for the measurement of the hyperfine splitting of $μ$p by the FAMU collaboration.

preprint2020arXiv

The laser diode calibration system of the ICARUS T600 detector at FNAL

The ICARUS T600 LAr TPC is the far detector of the Short Baseline Program at FNAL. As it will have to work at shallow depth in the Booster Neutrino Beam, a large cosmic rays background ($\sim 11$ kHz) will be present. To reduce it, precise timing information is needed from the new light detection system, based on 360 large area photomultipliers. For precise time measurements a calibration system based on a fast laser diode and a system based on one optical switch, several $1 \times 10$ fused fiber splitters, ultra-high vacuum optical feedthroughs and multimode optical patchcords up to 20 m long, to distribute the laser pulses to each single PMT, was designed. The time evolution of the PMTs' gain/timing and possibly their initial calibrations at a time $t_0$ will be done by using this system. The expected time resolution of this calibration system will be around 100 ps. The laboratory tests needed to set up the system are reported.