Researcher profile

R. B. Podviyanuk

R. B. Podviyanuk contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
9works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2013arXiv

Astrophysical and cosmological problems of invisible mass and dark energy in the Universe

The Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle Physics) of the National Academy of Sciences (NAS) of Ukraine "Astrophysical and cosmological problems of invisible mass and dark energy in the Universe" was held on November 21-22, 2012 in the Institute for Nuclear Research, Kyiv, Ukraine (http://lpd.kinr.kiev.ua/kmf12). This Project was carried out during three years (2010-2012) by scientists from various universities and institutes of the National Academy of Sciences of Ukraine; it was a logical continuation of the previous scientific program of the NAS of Ukraine "Researches of structure and composition of the Universe, hidden mass and dark energy (Kosmomikrofizyka)" in 2007-2009. These programs were devoted to theoretical and experimental investigations in astronomy, astrophysics, cosmology, physics of atomic nuclei and particle physics, which are related with the problems of dark matter and dark energy in the Universe.

preprint2013arXiv

CdWO4 crystal scintillators from enriched isotopes for double beta decay experiments

Cadmium tungstate crystal scintillators enriched in 106Cd and 116Cd were developed. The produced scintillators exhibit good optical and scintillation properties, and a low level of radioactive contamination. Experiments to search for double beta decay of 106Cd and 116Cd are in progress at the Gran Sasso National Laboratories of the INFN (Italy). Prospects to further improve the radiopurity of the detectors by recrystallization are discussed.

preprint2013arXiv

First results of the experiment to search for double beta decay of 106Cd with 106CdWO4 crystal scintillator in coincidence with four crystals HPGe detector

An experiment to search for double beta processes in 106Cd by using cadmium tungstate crystal scintillator enriched in 106Cd (106CdWO4) in coincidence with the four crystals HPGe detector GeMulti is in progress at the STELLA facility of the Gran Sasso underground laboratory of INFN (Italy). The 106CdWO4 scintillator is viewed by a low-background photomultiplier tube through a lead tungstate crystal light-guide produced from deeply purified archaeological lead to suppress gamma quanta from the photomultiplier tube. Here we report the first results of the experiment after 3233 hours of the data taking. A few new improved limits on double beta processes in 106Cd are obtained, in particular T1/2(2nuECb+) > 8.4e20 yr at 90% C.L.

preprint2013arXiv

Search for 2β decay of 116Cd with the help of enriched 116CdWO4 crystal scintillators

Cadmium tungstate crystal scintillators enriched in $^{116}$Cd to 82% ($^{116}$CdWO$_4$, total mass of $\approx$1.2 kg) are used to search for 2$β$ decay of $^{116}$Cd deep underground at the Gran Sasso National Laboratory of the INFN (Italy). The radioactive contamination of the $^{116}$CdWO$_4$ crystals has been studied carefully to reconstruct the background of the detector. The measured half-life of $^{116}$Cd relatively to 2$ν$2$β$ decay is $T^{2\nu2β}_{1/2}$ = [2.8 $\pm$ 0.05(stat.) $\pm$ 0.4(syst.)] $\times$ 10$^{19}$ yr, in agreement with the results of previous experiments. The obtained limit on the 0$ν$2$β$ decay of $^{116}$Cd (considering the data of the last 8696 h run with an advanced background 0.12(2) counts/yr/kg/keV in the energy interval 2.7-2.9 MeV) is $T_{1/2} \ge 1.0 \times 10^{23}$ yr at 90% C.L. The sensitivity of the experiment to the $0\nu2β$ process is $\lim T_{1/2} = 3 \times 10^{23}$ yr at 90% C.L. over 5 years of the measurements and it can be advanced (by further reduction of the background by a factor 3-30) to the level of $\lim T_{1/2} = (0.5-1.5) \times 10^{24}$ yr for the same period of the data taking.

preprint2012arXiv

Search for double beta decay processes in 106Cd with the help of 106CdWO4 crystal scintillator

A search for the double beta processes in 106Cd was carried out at the Gran Sasso National Laboratories of the INFN (Italy) with the help of a 106CdWO4 crystal scintillator (215 g) enriched in 106Cd up to 66%. After 6590 h of data taking, new improved half-life limits on the double beta processes in 106Cd were established at the level of 10^{19}-10^{21} yr; in particular, T_{1/2}(2νεβ^+) > 2.1 10^{20} yr, T_{1/2}(2ν2β^+) > 4.3 10^{20} yr, and T_{1/2}(0ν2ε) > 1.0 10^{21} yr. The resonant neutrinoless double electron captures to the 2718 keV, 2741 keV and 2748 keV excited states of 106Pd are restricted to T_{1/2}(0ν2K) > 4.3 10^{20} yr, T_{1/2}(0νKL1) > 9.5 10^{20} yr and T_{1/2}(0νKL3) > 4.3 10^{20} yr, respectively (all limits at 90% C.L.). A possible resonant enhancement of the 0ν2εprocesses is estimated in the framework of the QRPA approach. The radioactive contamination of the 106CdWO4 crystal scintillator is reported.

preprint2012arXiv

Searches for neutrinoless resonant double electron captures at LNGS

Several experiments were performed during last years at underground (3600 m w.e.) Laboratori Nazionali del Gran Sasso (LNGS) of the INFN (Italy) to search for resonant 2$\varepsilon0ν$ captures in 96Ru, 106Cd, 136Ce, 156Dy, 158Dy, 180W, 184Os, 190Pt with the help of HP Ge semiconductor detectors, and ZnWO4 and 106CdWO4 crystal scintillators. No evidence for r-2$\varepsilon0ν$ decays was found, and only T_{1/2} limits were established in the range of 10^{14}-10^{21} yr.

preprint2011arXiv

Low background detector with enriched 116CdWO4 crystal scintillators to search for double beta decay of 116Cd

A cadmium tungstate crystal boule enriched in $^{116}$Cd to 82% with mass of 1868 g was grown by the low-thermal-gradient Czochralski technique. The isotopic composition of cadmium and the trace contamination of the crystal were estimated by High Resolution Inductively Coupled Plasma Mass-Spectrometry. The crystal scintillators produced from the boule were subjected to characterization that included measurements of transmittance and energy resolution. A low background scintillation detector with two $^{116}$CdWO$_4$ crystal scintillators (586 g and 589 g) was developed. The detector was running over 1727 h deep underground at the Gran Sasso National Laboratories of the INFN (Italy), which allowed to estimate the radioactive contamination of the enriched crystal scintillators. The radiopurity of a third $^{116}$CdWO$_4$ sample (326 g) was tested with the help of ultra-low background high purity germanium $γ$ detector. Monte Carlo simulations of double $β$ processes in $^{116}$Cd were used to estimate the sensitivity of an experiment to search for double $β$ decay of $^{116}$Cd.

preprint2011arXiv

Radioactive contamination of SrI2(Eu) crystal scintillator

A strontium iodide crystal doped by europium (SrI2(Eu)) was produced by using the Stockbarger growth technique. The crystal was subjected to a characterization that includes relative photoelectron output and energy resolution for gamma quanta. The intrinsic radioactivity of the SrI2(Eu) crystal scintillator was tested both by using it as scintillator at sea level and by ultra-low background HPGe gamma spectrometry deep underground. The response of the SrI2(Eu) detector to alpha particles (alpha/beta ratio and pulse shape) was estimated by analysing the 226Ra internal trace contamination of the crystal. We have measured: alpha/beta=0.55 at E_alpha=7.7 MeV, and no difference in the time decay of the scintillation pulses induced by alpha particles and gamma quanta. The application of the obtained results in the search for the double electron capture and electron capture with positron emission in 84Sr has been investigated at a level of sensitivity: T_1/2 \sim 10^{15}-10^{16} yr. The results of these studies demonstrate the potentiality of this material for a variety of scintillation applications, including low-level counting experiments.

preprint2010arXiv

Radioactive contamination of ZnWO4 crystal scintillators

The radioactive contamination of ZnWO4 crystal scintillators has been measured deep underground at the Gran Sasso National Laboratory (LNGS) of the INFN in Italy with a total exposure 3197 kg x h. Monte Carlo simulation, time-amplitude and pulse-shape analyses of the data have been applied to estimate the radioactive contamination of the ZnWO4 samples. One of the ZnWO4 crystals has also been tested by ultra-low background gamma spectrometry. The radioactive contaminations of the ZnWO4 samples do not exceed 0.002 -- 0.8 mBq/kg (depending on the radionuclide), the total alpha activity is in the range: 0.2 - 2 mBq/kg. Particular radioactivity, beta active 65Zn and alpha active 180W, has been detected. The effect of the re-crystallization on the radiopurity of the ZnWO4 crystal has been studied. The radioactive contamination of samples of the ceramic details of the set-ups used in the crystals growth has been checked by low background gamma spectrometry. A project scheme on further improvement of the radiopurity level of the ZnWO4 crystal scintillators is briefly addressed.