Source author record

Qian Yue

Qian Yue appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2019arXiv

CDEX dark matter experiment: Status and prospects

The China Dark Matter Experiment (CDEX) aims at direct searches of light Weakly Interacting Massive Particles (WIMPs) at the China Jinping Underground Laboratory (CJPL) with an overburden of about 2400m rock. Results from a prototype CDEX-1 994 g p-type Point Contact Germanium(pPCGe) detector are reported. Research programs are pursued to further reduce the physics threshold by improving hardware and data analysis. The CDEX-10 experiment with a pPCGe array of 10 kg target mass range is being tested. The evolution of CDEX program into "CDEX-1T Experiment" with ton-scale germanium detector arrays will also be introduced in this study.

preprint2019arXiv

Results of direct dark matter detection with CDEX experiment at CJPL

The China Dark Matter Experiment (CDEX), located at the China Jinping Underground Laboratory (CJPL) whose overburden is about 2400m rock, aims at direct searches of light Weakly Interacting Massive Particles (WIMPs). A single-element 994-gram p-type point contact (PPC) germanium detector (CDEX-1B) runs inside a solid passive shielding system. To achieve lower background, a prototype 10kg PPC germanium detector array (CDEX-10), consisting of three detector strings with three germanium crystals each, is directly immersed in the liquid nitrogen. With the energy threshold of 160eV, the limits on WIMP-nucleus scattering are set by energy spectra and annual modulation analysis, respectively. Incorporating Migdal effect, the data of CDEX-1B are re-analyzed to search sub-GeV WIMPs. Finally, the future plan of CDEX experiment in CJPL-II is introduced.

preprint2016arXiv

Characterization study of a broad-energy germanium detector at CJPL

The ability of background discrimination using pulse shape discrimination (PSD) in broad-energy germanium (BEGe) detectors makes them as competitive candidates for neutrinoless double beta decay (0ν\b{eta}\b{eta}) experiments. The measurements of key parameters for detector modeling in a commercial p-type BEGe detector are presented in this paper. Point-like sources were used to investigate the energy resolution and linearity of the detector. A cylindrical volume source was used for the efficiency calibration. With an assembled device for source positioning, a collimated 133Ba point-like source was used to scan the detector and investigate the active volume. A point-like source of 241Am was used to measure the dead layer thicknesses, which are approximately 0.17 mm on the front and 1.18 mm on the side. The described characterization method will play an important role in the 0ν\b{eta}\b{eta} experiments with BEGe detectors at China JinPing underground Laboratory (CJPL) in the future.

preprint2015arXiv

Exothermic isospin-violating dark matter after SuperCDMS and CDEX

We show that exothermic isospin-violating dark matter (IVDM) can make the results of the latest CDMS-Si experiment consistent with recent null experiments, such as XENON10, XENON100, LUX, CDEX, and SuperCDMS, whereas for the CoGeNT experiment, a strong tension still persists. For CDMS-Si, separate exothermic dark matter or isospin-violating dark matter cannot fully ameliorate the tensions among these experiments; the tension disappears only if exothermic scattering is combined with an isospin-violating effect of f_n/f_p=-0.7. For such exothermic IVDM to exist, at least a new vector gauge boson (dark photon or dark Z') that connects SM quarks to Majorana-type DM particles is required.

preprint2014arXiv

Study of the material photon and electron background and the liquid argon detector veto efficiency of the CDEX-10 experiment

The China Dark Matter Experiment (CDEX) is located at the China Jinping underground laboratory (CJPL) and aims to directly detect the WIMP flux with high sensitivity in the low mass region. Here we present a study of the predicted photon and electron backgrounds including the background contribution of the structure materials of the germanium detector, the passive shielding materials, and the intrinsic radioactivity of the liquid argon that serves as an anti-Compton active shielding detector. A detailed geometry is modeled and the background contribution has been simulated based on the measured radioactivities of all possible components within the GEANT4 program. Then the photon and electron background level in the energy region of interest (<10^-2 events kg-1 day-1 keV-1 (cpkkd)) is predicted based on Monte Carlo simulations. The simulated result is consistent with the design goal of CDEX-10 experiment, 0.1 cpkkd, which shows that the active and passive shield design of CDEX-10 is effective and feasible.

preprint2014arXiv

The characteristics of a low background germanium gamma ray spectrometer at China JinPing underground Laboratory

A low background germanium gamma ray spectrometer, GeTHU, has been installed at China JinPing underground Laboratory. The integral background count rate between 40 and 2700 keV was 0.6 cpm, and the origin was studied by Monte Carlo simulation. Detection limits and efficiencies were calculated for selected gamma peaks. Boric acid and silica sand samples were measured and 137Cs contamination was found in boric acid. GeTHU will be mainly used to measure environmental samples and screen materials in dark matter experiments.

preprint2013arXiv

A background simulation method for cosmogenic nuclides inside HPGe detectors for rare event experiments

Cosmogenic nuclides inside germanium detectors contribute background noise spectra quite different from ordinary external sources. We propose and discuss a nuclide decay and level transition model based on graph theory to understand the background contribution of the decay of cosmogenic nuclides inside a germanium crystal. In this work, not only was the level transition process, but the detector response time was also taken into consideration to decide whether or not to apply coincidence summing-up. We simulated the background spectrum of the internal cosmogenic nuclides in a germanium detector, and found some unique phenomena caused by the coincidence summing-up effect in the simulated spectrum. Thus, the background spectrum of each cosmogenic nuclide can be quantitatively obtained.

preprint2013arXiv

Characterization of large area photomultiplier ETL 9357FLB for liquid argon detector

The China Dark Matter Experiment (CDEX) Collaboration will carry out a direct search for weakly interacting massive particles with germanium detectors. Liquid argon will be utilized as an anti-Compton and cooling material for the germanium detectors. A low-background and large-area photomultiplier tube (PMT) immersed in liquid argon will be used to read out the light signal from the argon. In this paper we carry out a careful evaluation on the performance of the PMT operating at both room and cryogenic temperatures. Based on the single photoelectron response model, the absolute gain and resolution of the PMT were measured. This has laid a foundation for PMT selection, calibration and signal analysis in the forthcoming CDEX experiments.

preprint2013arXiv

Introduction of the CDEX experiment

Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.

preprint2013arXiv

The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches

The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.