Researcher profile

Qi Hui-Rong

Qi Hui-Rong contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Discriminating cosmic muon and x-ray based on rising time using GEM detector

Gas electron multiplier(GEM) detector is used in Cosmic Muon Scattering Tomography and neutron imaging in the last decade. In this work, a triple GEM device with an effective readout area of 10 cm X 10 cm is developed, and an experiment of discriminating between cosmic muon and x-ray based on rising time is tested. The energy resolution of GEM detector is tested by 55Fe ray source to prove the GEM detector has a good performance. The analysis of the complete signal-cycles allows to get the rising time and pulse heights. The experiment result indicates that cosmic muon and x-ray can be discriminated with an appropriate rising time threshold.

preprint2013arXiv

Beam test of a one-dimensional position sensitive chamber on synchrotron radiation

One-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 um (sigma value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of detector. The effect was analyzed and it came to a conclusion that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm.