Source author record

Q. Bodart

Q. Bodart appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2013arXiv

Sensitivity limits of a Raman atom interferometer as a gravity gradiometer

We evaluate the sensitivity of a dual cloud atom interferometer to the measurement of vertical gravity gradient. We study the influence of most relevant experimental parameters on noise and long-term drifts. Results are also applied to the case of doubly differential measurements of the gravitational signal from local source masses. We achieve a short term sensitivity of 3*10^(-9) g/Hz^(-1/2) to differential gravity acceleration, limited by the quantum projection noise of the instrument. Active control of the most critical parameters allows to reach a resolution of 5*10^(-11) g after 8000 s on the measurement of differential gravity acceleration. The long term stability is compatible with a measurement of the gravitational constant G at the level of 10^(-4) after an integration time of about 100 hours.

preprint2010arXiv

Comparison between two mobile absolute gravimeters: optical versus atomic interferometers

We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.

preprint2010arXiv

Comparison of 3 absolute gravimeters based on different methods for the e-MASS project

We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their measurements of the gravitational acceleration in 4 points of the same pillar, in the perspective of an absolute determination of g for a watt balance experiment