Source author record

F. Pereira Dos Santos

F. Pereira Dos Santos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

Gravity Field Mapping Using Laser Coupled Quantum Accelerometers in Space

The emergence of quantum technologies, including cold atom based accelerometers, offers an opportunity to improve the performances of space geodesy missions. In this context, CNES initiated an assessment study called GRICE (GRadiométrie à Interféromètres quantiques Corrélés pour l'Espace) in order to evaluate the contribution of cold atom technologies to space geodesy and to the end users of geodetic data. In this paper, we present mission scenario for gravity field mapping based on a long baseline gradiometer. The mission is based on a constellation of two satellites, flying at an altitude of 373 km, each equipped with a cold atom accelerometer with a sensitivity of $6 \times 10^{-10}$~m.s$^{-2}$.$\mathrmτ^{-1/2}$. A laser link measures the distance between the two satellites and couples these two instruments in order to produce a correlated differential acceleration measurement. The main parameters, determining the performances of the payload, have been investigated. We carried out a general study of satellite architecture and simulations of the mission performances in terms of restitution of the gravity field. The simulations show that this concept would give its best performance in terms of monthly gravity fields recovery under 1000~km resolution. In the resolution band between 1000 and 222~km, the improvement of the GRICE gradient approach over the traditional range-rate approach is globally in the order of 10 to 25\%.

preprint2020arXiv

Technologies for the ELGAR large scale atom interferometer array

We proposed the European Laboratory for Gravitation and Atom-interferometric Research (ELGAR), an array of atom gradiometers aimed at studying space-time and gravitation with the primary goal of observing gravitational waves (GWs) in the infrasound band with a peak strain sensitivity of $3.3 \times 10^{-22}/\sqrt{\text{Hz}}$ at 1.7 Hz. In this paper we detail the main technological bricks of this large scale detector and emphasis the research pathways to be conducted for its realization. We discuss the site options, atom optics, and source requirements needed to reach the target sensitivity. We then discuss required seismic isolation techniques, Gravity Gradient Noise reduction strategies, and the metrology of various noise couplings to the detector.

preprint2015arXiv

Influence of chirping the Raman lasers in an atom gravimeter: phase shifts due to the Raman light shift and to the finite speed of light

We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the resonance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the two Raman lasers is enough to bias the gravity measurement by a fraction of $μ$Gal ($1~μ$Gal~=~$10^{-8}$~m/s$^2$). We also show that this effect is not compensated when averaging over the two directions of the Raman wavevector $k$. This thus constitutes a limit to the rejection efficiency of the $k$-reversal technique. Our analysis allows us to separate this effect from the effect of the finite speed of light, which we find in perfect agreement with expected values. This study highlights the benefit of chirping symmetrically the two Raman lasers.

preprint2011arXiv

Perturbations of the local gravity field due to mass distribution on precise measuring instruments: a numerical method applied to a cold atom gravimeter

We present a numerical method, based on a FEM simulation, for the determination of the gravitational field generated by massive objects, whatever geometry and space mass density they have. The method was applied for the determination of the self gravity effect of an absolute cold atom gravimeter which aims at a relative uncertainty of 10-9. The deduced bias, calculated with a perturbative treatment, is finally presented. The perturbation reaches (1.3 \pm 0.1) \times 10-9 of the Earth's gravitational field.

preprint2010arXiv

Comparison between two mobile absolute gravimeters: optical versus atomic interferometers

We report a comparison between two absolute gravimeters: the LNE-SYRTE cold atoms gravimeter and FG5#220 of Leibniz Universität of Hannover. They rely on different principles of operation: atomic and optical interferometry. Both are movable which enabled them to participated to the last International Comparison of Absolute Gravimeters (ICAG'09) at BIPM. Immediately after, their bilateral comparison took place in the LNE watt balance laboratory and showed an agreement of 4.3 +/- 6.4 μGal.

preprint2010arXiv

Comparison of 3 absolute gravimeters based on different methods for the e-MASS project

We report on the comparison between three absolute gravimeters that took place in April 2010 at Laboratoire National de Métrologie et d'Essais. The three instruments (FG5#209 from METAS, Switzerland, IMGC-02 from INRIM, Italy, and CAG from LNE-SYRTE, France) rely on different methods: optical and atomic interferometry. We discuss their differences as well as their similarities. We compare their measurements of the gravitational acceleration in 4 points of the same pillar, in the perspective of an absolute determination of g for a watt balance experiment

preprint2005arXiv

Transportable laser system for atom interferometry

We describe an optical bench in which we lock the relative frequencies or phases of a set of three lasers in order to use them in a cold atoms interferometry experiment. As a new feature, the same two lasers serve alternately to cool atoms and to realize the atomic interferometer. This requires a fast change of the optical frequencies over a few GHz. The number of required independent laser sources is then only 3, which enables the construction of the whole laser system on a single transportable optical bench. Recent results obtained with this optical setup are also presented.