Researcher profile

Prithvi Suresh

Prithvi Suresh contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Gait Recovery System for Parkinson's Disease using Machine Learning on Embedded Platforms

Freezing of Gait (FoG) is a common gait deficit among patients diagnosed with Parkinson's Disease (PD). In order to help these patients recover from FoG episodes, Rhythmic Auditory Stimulation (RAS) is needed. The authors propose a ubiquitous embedded system that detects FOG events with a Machine Learning (ML) subsystem from accelerometer signals . By making inferences on-device, we avoid issues prevalent in cloud-based systems such as latency and network connection dependency. The resource-efficient classifier used, reduces the model size requirements by approximately 400 times compared to the best performing standard ML systems, with a trade-off of a mere 1.3% in best classification accuracy. The aforementioned trade-off facilitates deployability in a wide range of embedded devices including microcontroller based systems. The research also explores the optimization procedure to deploy the model on an ATMega2560 microcontroller with a minimum system latency of 44.5 ms. The smallest model size of the proposed resource efficient ML model was 1.4 KB with an average recall score of 93.58%.

preprint2020arXiv

Robust Modelling of Reflectance Pulse Oximetry for SpO$_2$ Estimation

Continuous monitoring of blood oxygen saturation levels is vital for patients with pulmonary disorders. Traditionally, SpO$_2$ monitoring has been carried out using transmittance pulse oximeters due to its dependability. However, SpO$_2$ measurement from transmittance pulse oximeters is limited to peripheral regions. This becomes a disadvantage at very low temperatures as blood perfusion to the peripherals decreases. On the other hand, reflectance pulse oximeters can be used at various sites like finger, wrist, chest and forehead. Additionally, reflectance pulse oximeters can be scaled down to affordable patches that do not interfere with the user's diurnal activities. However, accurate SpO$_2$ estimation from reflectance pulse oximeters is challenging due to its patient dependent, subjective nature of measurement. Recently, a Machine Learning (ML) method was used to model reflectance waveforms onto SpO$_2$ obtained from transmittance waveforms. However, the generalizability of the model to new patients was not tested. In light of this, the current work implemented multiple ML based approaches which were subsequently found to be incapable of generalizing to new patients. Furthermore, a minimally calibrated data driven approach was utilized in order to obtain SpO$_2$ from reflectance PPG waveforms. The proposed solution produces an average mean absolute error of 1.81\% on unseen patients which is well within the clinically permissible error of 2\%. Two statistical tests were conducted to establish the effectiveness of the proposed method.