Researcher profile

Pierre Gillot

Pierre Gillot contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Coherent population trapping in a Raman atom interferometer

We investigate the effect of coherent population trapping (CPT) in an atom inter-ferometer gravimeter based on the use of stimulated Raman transitions. We find that CPT leads to significant phase shifts, of order of a few mrad, which may compromise the accuracy of inertial measurements. We show that this effect is rejected by the k-reversal technique, which consists in averaging inertial measurements performed with two opposite orientations of the Raman wavevector k, provided that internal states at the input of the interferometer are kept identical for both configurations.

preprint2016arXiv

Metrology with Atom Interferometry: Inertial Sensors from Laboratory to Field Applications

Developments in atom interferometry have led to atomic inertial sensors with extremely high sensitivity. Their performances are for the moment limited by the ground vibrations, the impact of which is exacerbated by the sequential operation, resulting in aliasing and dead time. We discuss several experiments performed at LNE-SYRTE in order to reduce these problems and achieve the intrinsic limit of atomic inertial sensors. These techniques have resulted in transportable and high-performance instruments that participate in gravity measurements, and pave the way to applications in inertial navigation.

preprint2014arXiv

Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection

We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in {\it Louchet-Chauvet et al., NJP 13, 065025 (2011)}, where the mean phase shift due to Coriolis acceleration was found to have a sign different from expected.

preprint2014arXiv

Stability comparison of two absolute gravimeters: optical versus atomic interferometers

We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to changes in the level of vibration noise, as well as a slightly better short term stability.