Source author record

Petr Shagin

Petr Shagin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Ultra-Intense Gamma-Rays Created Using the Texas Petawatt Laser

In a series of experiments at the Texas Petawatt Laser (TPW) in Austin, TX, we have used attenuation spectrometers, dosimeters, and a new Forward Compton Electron Spectrometer (FCES) to measure and characterize the angular distribution, fluence, and energy spectrum of the X-rays and gamma rays produced by the TPW striking multi-millimeter thick gold targets. Our results represent the first such measurements at laser intensities > 10 21 W*cm-2 and pulse durations < 150 fs. We obtain a maximum yield of X-ray and gamma ray energy with respect to laser energy of 4% and a mean yield of 2%. We futher obtain a Full Width Half Maximum (FWHM) of the gamma distribution of 37°. We were able to characterize the gamma-ray spectrum from 3 MeV to 90 MeV using a Forward Compton Electron Spectrometer, with an energy resolution of 0.5 MeV and mean kT of ~ 6 MeV.. We were able to characterize the spectrum from 1 to 7 MeV using a Filter Stack Spectrometer, measuring a mean gamma-ray temperature for the spectrum from 3 to 7 MeV of 2.1 MeV.

preprint2012arXiv

Performance of a cryogenic system prototype for the XENON1T Detector

We have developed an efficient cryogenic system with heat exchange and associated gas purification system, as a prototype for the XENON1T experiment. The XENON1T detector will use about 3 ton of liquid xenon (LXe) at a temperature of 175K as target and detection medium for a dark matter search. In this paper we report results on the cryogenic system performance focusing on the dynamics of the gas circulation-purification through a heated getter, at flow rates above 50 Standard Liter per Minute (SLPM). A maximum flow of 114 SLPM has been achieved, and using two heat exchangers in parallel, a heat exchange efficiency better than 96% has been measured.