Researcher profile

Peter Forck

Peter Forck contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Beam Instrumentation and Diagnostics

The determination of beam parameters is essential for the operation and development of any accelerator facility. The working principle of frequently used beam instruments for electron and proton beams is discussed. The article comprises of the beam instrumentation for beam current determination, the usage of beam position monitors for bunched beams, methods for transverse profile and emittance diagnostics, bunch shape measurement and the usage of beam loss monitors.

preprint2020arXiv

Performance of closed orbit feedback systems with spatial model mismatch

Closed orbit feedback (COFB) systems used for the global orbit correction rely on the pseudo-inversion of the orbit response matrix (ORM). A mismatch between the model ORM used in the controller and the actual machine ORM can affect the performance of the feedback system. In this paper, the typical sources of such model mismatch such as acceleration ramp ORM variation, intensity-dependent tune shift and beta beating are considered in simulation studies. Their effect on the performance and the stability margins are investigated for both the slow and fast regimes of a COFB system operation. The spectral radius stability condition is utilized instead of the small gain theorem to arrive at the theoretical limits of COFB stability and comparisons with simulations for SIS18 of GSI and experiments at the Cooler synchrotron (COSY) in the Forschungzentrum Jülich (FZJ) are also presented.

preprint2019arXiv

Smoothing of the slowly extracted coasting beam from a synchrotron

Slow extraction of beam from synchrotrons or storage rings as required by many fixed target experiments is performed by controlled excitation and feeding of a structural lattice resonance. Due to the sensitive nature of this resonant extraction process, the temporal structure of the extracted beam is modulated by the minuscule current fluctuations present on the quadrupole magnet power supplies. Such a modulation lead to pile-ups in detectors and a significant reduction in accumulated event statistics. This contribution proposes and experimentally demonstrates that by an introduction of further modulation on quadrupole currents with a specific amplitude and frequency, the inherent power supply fluctuations are mitigated leading to a smoothening of the beam temporal structure. The slow extraction beam dynamics associated with this method are explained along with the operational results.