Published work

4 published item(s)

preprint2026arXiv

Towards a temperature-insensitive composite diamond clock

Frequency references based on solid state spins promise simplicity, compactness, robustness, multifunctionality, ease of integration, and high densities of emitters. Nitrogen-vacancy (NV) centers in diamond are a natural candidate, but the electronic zero-field splitting exhibits a large fractional temperature dependence, which has precluded its use as a stable clock transition. Here we show that this limitation can be overcome by forming a composite frequency reference that combines measurements of the electronic splitting D with the nuclear quadrupole splitting of the $^{14}$N nuclear spin intrinsic to the NV center. We further benchmark this composite approach against alternative strategies for mitigating temperature sensitivity. By implementing a specially designed pulse sequence with an eight-phase control scheme that suppresses pulse imperfections, we interleave measurements of D and Q in a high-density NV ensemble and demonstrate a temperature-compensated composite frequency reference. The stability of this composite diamond clock is characterized over a 10-day period at room temperature through a comparison to a Rb vapor-cell clock, yielding a fractional instability below $5 \times 10^{-9}$ for an averaging time of $τ= 200$ s and below $1 \times 10^{-8}$ at $τ= 2 \times 10^5$ s, corresponding to measured improvements by a factor of 4 and 200, respectively, over a clock based purely on the single frequency D for the same periods. By characterizing the residual sensitivity to magnetic fields, optical power, and radio-frequency drive amplitudes, we find that temperature is no longer the dominant source of instability. These results establish complementary electron- and nuclear-spin transitions in diamond as a viable route to thermally robust frequency metrology, providing a pathway toward compact, multifunctional solid-state clocks and quantum sensors.

preprint2021arXiv

Fiberized diamond-based vector magnetometers

We present two fiberized vector magnetic-field sensors, based on nitrogen-vacancy (NV) centers in diamond. The sensors feature sub-nT/$\sqrt{\textrm{Hz}}$ magnetic sensitivity. We use commercially available components to construct sensors with a small sensor size, high photon collection, and minimal sensor-sample distance. Both sensors are located at the end of optical fibres with the sensor-head freely accessible and robust under movement. These features make them ideal for mapping magnetic fields with high sensitivity and spatial resolution ($\leq$\,mm). As a demonstration we use one of the sensors to map the vector magnetic field inside the bore of a $\geq$ 100\,mT Halbach array. The vector field sensing protocol translates microwave spectroscopy data addressing all diamonds axes and including double quantum transitions to a 3D magnetic field vector.

preprint2015arXiv

Permanent Magnet System for MRI with Constant Gradient mechanically adjustable in Direction and Strength

A design for a permanent magnet system is proposed that generates spatially homogeneous, constant magnetic field gradients, thus creating conditions suitable for MRI without gradient coils and amplifiers. This is achieved by superimposing a weak Halbach quadrupole on a strong Halbach dipole. Rotation of either the quadrupole or the entire magnet assembly can be used to generate 2D images via filtered back-projection. Additionally, the mutual rotation of two quadrupoles can be used to scale the resulting gradient. If both gradients have identical strength the gradient can even be made to vanish. The concept is demonstrated by analytical considerations and FEM-simulations.

preprint2015arXiv

Spherical Fused Silica Cells Filled with Pure Helium for NMR-Magnetometry

High magnetic fields (> 1 T) are measured by NMR magnetometers with un-rivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted ${}^{3}$He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field the optimal container for the ${}^{3}$He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO${}_{2}$ laser and the inner volume was filled with a few mbars of ${}^3$He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with < 1 $μ$m deviation from sphericity, the bonding left a step of ca. 50 $μ$m at maximum. The influence of such a mismatch, its orientation and materials in the direct vicinity of the sample are analyzed by FEM-simulations and discussed in view of coherence times and absolute fields.