Source author record

Peter Bachert

Peter Bachert appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Diffusion pore imaging in the presence of extraporal water

Diffusion-weighted imaging (DWI) is a powerful non-invasive tool which is widely used in clinical routine. Mostly, apparent diffusion coefficient maps are acquired, which cannot be directly related to cellular structure. More recently it was shown that DWI is able to reconstruct pore shapes using a specialized magnetic field gradient scheme so that cell size distributions may be obtained. So far, artificial systems have been used for experimental demonstration without extraporal signal components and relatively low gradient amplitudes. Therefore, the aim of this study was to investigate the feasibility of diffusion pore imaging in the presence of extraporal fluids and to develop correction methods for effects arising from extraporal signal contributions. Monte Carlo simulations and validation experiments on a 14.1 T spectrometer with a dedicated diffusion probe head were performed. Both by using a filter gradient approach suppressing extraporal signal components as well as using postprocessing methods relying on the Gaussian phase approximation, it was possible to reconstruct pore space functions in the presence of extraporal fluids with little to no deviations from the expectations. These results may be a significant step towards application of diffusion pore imaging to biological samples. While still ultra-high gradients are required, this problem may be mitigated by recent developments in the field of local gradient coils for human applications.

preprint2013arXiv

Inverse Z-spectrum analysis for MT- and spillover-corrected and T1-compensated steady-state pulsed CEST-MRI - application to pH-weighted MRI of acute stroke

Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects such as direct water proton saturation (spillover) and macromolecular magnetization transfer (MT). This leads to T2-and MT-shine-through effects in the actual biochemical contrast of CEST. Therefore, a simple evaluation algorithm which corrects the CEST signal was searched for. By employing a recent eigenspace theory valid for spinlock and continuous wave (cw) CEST we predict that the inverse Z-spectrum is beneficial to Z-spectrum itself. Based on this we propose a new spillover- and MT-corrected magnetization transfer ratio (MTRRex) yielding Rex, the exchange dependent relaxation rate in the rotating frame. For verification, the amine proton exchange of creatine in solutions with different agar concentration was studied experimentally at clinical field strength of 3T. In contrast to the compared standard evaluation for pulsed CEST experiments, MTRasym, our approach shows no T2 or MT shine through effect. We demonstrate that spillover can be corrected properly and also quantitative evaluation of pH and creatine concentration is possible which proves MTRRex as quantitative CEST-MRI method. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for -OH-CEST effects like gagCEST or glucoCEST, but also amine exchange of creatine or glutamate which require high B1. Although, only showed for amine exchange, we propose our normalization to work generally for DIACEST, PARACEST in slow- and fast exchange regime not just as a correction, but also for quantitative CEST-MRI. Applied to acute stroke induced in rat brain, the corrected CEST signal shows significantly higher contrast between stroke area and normal tissue as well as less B1 dependency compared to conventional approaches.

preprint2012arXiv

Diffusion Pore Imaging by Hyperpolarized Xenon-129 Nuclear Magnetic Resonance

Nuclear magnetic resonance (NMR) diffusion measurements are widely used to derive parameters indirectly related to the microstructure of biological tissues and porous media. However, a direct imaging of cell or pore shapes and sizes would be of high interest. For a long time, determining pore shapes by NMR diffusion acquisitions seemed impossible, because the necessary phase information could not be preserved. Here we demonstrate experimentally using the measurement technique which we have recently proposed theoretically that the shape of arbitrary closed pores can be imaged by diffusion acquisitions, which yield the phase information. For this purpose, we use hyperpolarized xenon gas in well-defined geometries. The signal can be collected from the whole sample which mainly eliminates the problem of vanishing signal at increasing resolution of conventional NMR imaging. This could be used to non-invasively gain structural information inaccessible so far such as pore or cell shapes, cell density or axon integrity.

preprint2012arXiv

Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange - modeling off-resonant spin-lock and chemical exchange saturation transfer

Chemical exchange observed by NMR saturation transfer (CEST) and spin-lock (SL) experiments provide an MRI contrast by indirect detection of exchanging protons. The determination of the relative concentrations and exchange rates is commonly achieved by numerical integration of the Bloch-McConnell equations. We derive an analytical solution of the Bloch-McConnell equations that describes the magnetization of coupled spin populations under radiofrequency irradiation.As CEST and off-resonant SL are equivalent, their steady-state magnetization and dynamics can be predicted by the same single eigenvalue: the longitudinal relaxation rate in the rotating frame R1rho. For the case of slowly exchanging systems, e.g. amide protons, the saturation of the small proton pool is affected by transverse relaxation (R2b). It turns out, that R2b is also significant for intermediate exchange, such as amine- or hydroxyl-exchange or paramagnetic CEST agents, if pools are only partially saturated. We propose a solution for R1rho that includes R2 of the exchanging pool by extending existing approaches, and verify it by numerical simulations. With the appropriate projection factors, we obtain an analytical solution for CEST and SL for nonzero R2 of the exchanging pool, whilst considering the dilution by direct water saturation across the entire Z-spectra. This allows the optimization of irradiation parameters and the quantification of pH-dependent exchange rates and metabolite concentrations. In addition, we propose evaluation methods that correct for concomitant direct saturation effects. It is shown that existing theoretical treatments for CEST are special cases of this approach.