Source author record

Peng Dong

Peng Dong appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Patient-specific mean teacher UNet for enhancing PET image and low-dose PET reconstruction on RefleXion X1 biology-guided radiotherapy system

The RefleXion X1 is the first biology-guided radiotherapy (BgRT) system. Its dual 90-degree PET detector collects fewer pair production events compared to a full-ring diagnostic PET system. In the proposed BgRT workflow, a short scan is acquired before treatment delivery to ensure image quality and consistency. The shorter scan time, a quarter of the simulation scan time, also leads to fewer coincidence events and hence reduced image quality. In this study, we proposed a patient-specific mean teacher UNet (MT-UNet) to enhance PET image quality and low-dose PET reconstruction on RefleXion X1. PET/CT scans of nine cancer patients were acquired using RefleXion X1. Every patient had one simulation scan. Five patients had additional scans acquired during the first and the final treatment fractions. Treatment scans were acquired using the same imaging protocol as the simulation scan. For each scan, we reconstructed a full-dose image and evenly split coincidence events into four sessions to reconstruct four quarter-dose PET images. For each patient, our proposed MT-UNet was trained using quarter-dose and full-dose images of the simulation scan. For the image quality enhancement task, we applied nine trained MT-UNets to full-dose simulation PET images of the nine patients to generate enhanced images, respectively. The enhanced images were compared with the original full-dose images using CNR and SNR. For the low-dose image reconstruction task, we applied five trained MT-UNets to ten quarter-dose treatment images of five patients to predict full-dose images, respectively. The predicted and ground truth full-dose images were compared using SSIM and PSNR. We also trained and evaluated patient-specific UNets for model comparison. Our proposed patient-specific MT-UNet achieved better performance in improving the quality of RefleXion low-dose and full-dose images compared to the patient-specific UNet.

preprint2020arXiv

Data-driven dose calculation algorithm based on deep learning

In this study we performed a feasibility investigation on implementing a fast and accurate dose calculation based on a deep learning technique. A two dimensional (2D) fluence map was first converted into a three dimensional (3D) volume using ray traversal algorithm. A 3D U-Net like deep residual network was then established to learn a mapping between this converted 3D volume, CT and 3D dose distribution. Therefore an indirect relationship was built between a fluence map and its corresponding 3D dose distribution without using significantly complex neural networks. 200 patients, including nasopharyngeal, lung, rectum and breast cancer cases, were collected and applied to train the proposed network. Additional 47 patients were randomly selected to evaluate the accuracy of the proposed method through comparing dose distributions, dose volume histograms (DVH) and clinical indices with the results from a treatment planning system (TPS), which was used as the ground truth in this study. Results: The proposed deep learning based dose calculation algorithm achieved good predictive performance. For 47 tested patients, the average per-voxel bias of the deep learning calculated value and standard deviation (normalized to the prescription), relative to the TPS calculation, is 0.17%. The average deep learning calculated values and standard deviations for relevant clinical indices were compared with the TPS calculated results and the t-test p-values demonstrated the consistency between them. Conclusions: In this study we developed a new deep learning based dose calculation method. This approach was evaluated by the clinical cases with different sites. Our results demonstrated its feasibility and reliability and indicated its great potential to improve the efficiency and accuracy of radiation dose calculation for different treatment modalities

preprint2016arXiv

Gravitational wave astronomy: the current status

In the centenary year of Einstein's General Theory of Relativity, this paper reviews the current status of gravitational wave astronomy across a spectrum which stretches from attohertz to kilohertz frequencies. Sect. 1 of this paper reviews the historical development of gravitational wave astronomy from Einstein's first prediction to our current understanding the spectrum. It is shown that detection of signals in the audio frequency spectrum can be expected very soon, and that a north-south pair of next generation detectors would provide large scientific benefits. Sect. 2 reviews the theory of gravitational waves and the principles of detection using laser interferometry. The state of the art Advanced LIGO detectors are then described. These detectors have a high chance of detecting the first events in the near future. Sect. 3 reviews the KAGRA detector currently under development in Japan, which will be the first laser interferometer detector to use cryogenic test masses. Sect. 4 of this paper reviews gravitational wave detection in the nanohertz frequency band using the technique of pulsar timing. Sect. 5 reviews the status of gravitational wave detection in the attohertz frequency band, detectable in the polarisation of the cosmic microwave background, and discusses the prospects for detection of primordial waves from the big bang. The techniques described in sects. 1-5 have already placed significant limits on the strength of gravitational wave sources. Sects. 6 and 7 review ambitious plans for future space based gravitational wave detectors in the millihertz frequency band. Sect. 6 presents a roadmap for development of space based gravitational wave detectors by China while sect. 7 discusses a key enabling technology for space interferometry known as time delay interferometry.

preprint2014arXiv

Descope of the ALIA mission

The present work reports on a feasibility study commissioned by the Chinese Academy of Sciences of China to explore various possible mission options to detect gravitational waves in space alternative to that of the eLISA/LISA mission concept. Based on the relative merits assigned to science and technological viability, a few representative mission options descoped from the ALIA mission are considered. A semi-analytic Monte Carlo simulation is carried out to understand the cosmic black hole merger histories starting from intermediate mass black holes at high redshift as well as the possible scientific merits of the mission options considered in probing the light seed black holes and their coevolution with galaxies in early Universe. The study indicates that, by choosing the armlength of the interferometer to be three million kilometers and shifting the sensitivity floor to around one-hundredth Hz, together with a very moderate improvement on the position noise budget, there are certain mission options capable of exploring light seed, intermediate mass black hole binaries at high redshift that are not readily accessible to eLISA/LISA, and yet the technological requirements seem to within reach in the next few decades for China.