Source author record

Pavla Šenjug

Pavla Šenjug appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Single-layer Compton detectors for measurement of polarization correlations of annihilation quanta

Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since polarization can be measured via Compton scattering, the initial orthogonality of polarizations can be translated to correlation of azimuthal scattering angles, and this correlation may be exploited as an additional handle to identify the true coincidence events. To examine the concept of using the polarization correlations in PET, we have used a system of two compact, position and energy-sensitive Compton detectors in coincidence mode. Each consists of a single matrix of scintillation pixels, read-out by an array of Silicon photomultipliers. The Compton events in each module are clearly identified and the scattering angles are reconstructed from the energy deposition and event topology. We have extracted the polarimetric modulation factors from the distributions of the difference of the azimuthal angles of the two Compton-scattered gammas and studied their dependence on Compton scattering angles $θ$ and on azimuthal resolution $Δϕ$. For scattering angles around $θ_{1,2}=82^\circ$, where the maximum modulation is expected, the modulation factors from $μ=0.15\pm 0.01$ to $μ=0.27\pm 0.02$ have been measured, depending on the azimuthal resolution, which is governed by event topology in the detectors. Analogously, for scattering around $θ_{1,2}=70^\circ$, modulation factors from $μ=0.12\pm 0.01$ to $μ=0.21\pm 0.02$ have been obtained. The results show that the measurement of the polarization correlations of annihilation quanta are feasible with compact single-layer, single-side read-out detectors, which may be used to build cost-efficient systems for various applications where gamma-ray polarization information is of interest.