Researcher profile

P. Schmidt-Wellenburg

P. Schmidt-Wellenburg contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2026arXiv

Community input to the European Strategy on particle physics: Searches for Permanent Electric Dipole Moments

Searches for electric dipole moments (EDMs) in fundamental particles and quantum systems with spin are pivotal experiments at the intersection of low-energy and high-precision particle physics. These investigations offer a complementary pathway to uncovering new physics beyond the Standard Model, parallel to high-energy collider searches. EDM experiments are among the most sensitive probes for detecting non-standard time-reversal (T) symmetry violations and, via the CPT theorem, CP-violation (CPV). Current EDM measurements test new physics at mass scales in or above the 10TeV to 100TeV range. This community input to the European Particle Physics Strategy Update highlights the status of the field, and describes challenges and opportunities in Europe.

preprint2022arXiv

$n-n'$ Oscillations: Sensitivity of a first UCN beam experiment

Oscillations of the neutron into a hidden sector particle are processes predicted in various Standard Model extensions. This extra channel for neutron disappearance has not been tested experimentally in large portions of the oscillation parameter space. Several efforts have been recently made on revising the oscillation time limits at low mass-splitting in ultra-cold neutron (UCN) storage experiments, and at larger mass-splitting in passing-through-wall experiments. In this work, we present the expected sensitivity of an experiment searching for neutron hidden neutron oscillations at intermediate mass-splitting via the application of magnetic fields in the range $B_0=30-1100$ $μ$T. This experiment was performed at the Institut-Laue-Langevin using a novel UCN counter to monitor the beam flux. The measured UCN rate and the data collection technique predict a sensitivity on the oscillation time at the level of a couple of seconds.

preprint2022arXiv

Search for the muon electric dipole moment using frozen-spin technique at PSI

The presence of a permanent electric dipole moment in an elementary particle implies Charge-Parity symmetry violation and thus could help explain the matter-antimatter asymmetry observed in our universe. Within the context of the Standard Model, the electric dipole moment of elementary particles is extremely small. However, many Standard Model extensions such as supersymmetry predict large electric dipole moments. Recently, the muon electric dipole moment has become a topic of particular interest due to the tensions in the magnetic anomaly of the muon and the electron, and hints of lepton-flavor universality violation in B-meson decays. In this article, we discuss a dedicated effort at the Paul Scherrer Institute in Switzerland to search for the muon electric dipole moment using a 3-T compact solenoid storage ring and the frozen-spin technique. This technique could reach a sensitivity of $6\times10^{-23}$ $e\cdot$cm after a year of data taking with the $p=125$ MeV/$c$ muon beam at the Paul Scherrer Institute. This allows us to probe various Standard Model extensions not reachable by traditional searches using muon $g-2$ storage rings.

preprint2021arXiv

Search for a muon EDM using the frozen-spin technique

This letter of intent proposes an experiment to search for an electric dipole moment of the muon based on the frozen-spin technique. We intend to exploit the high electric field, $E=1{\rm GV/m}$, experienced in the rest frame of the muon with a momentum of $p=125 {\rm MeV/}c$ when passing through a large magnetic field of $|\vec{B}|=3{\rm T}$. Current muon fluxes at the $μ$E1 beam line permit an improved search with a sensitivity of $σ(d_μ)\leq 6\times10^{-23}e{\rm cm}$, about three orders of magnitude more sensitivity than for the current upper limit of $|d_μ|\leq1.8\times10^{-19}e{\rm cm}$\,(C.L. 95\%). With the advent of the new high intensity muon beam, HIMB, and the cold muon source, muCool, at PSI the sensitivity of the search could be further improved by tailoring a re-acceleration scheme to match the experiments injection phase space. While a null result would set a significantly improved upper limit on an otherwise un-constrained Wilson coefficient, the discovery of a muon EDM would corroborate the existence of physics beyond the Standard Model.

preprint2021arXiv

Ultracold neutron storage and transport at the PSI UCN source

Efficient neutron transport is a key ingredient to the performance of ultracold neutron (UCN) sources, important to meeting the challenges placed by high precision fundamental physics experiments. At the Paul Scherrer Institute's UCN source we have been continuously improving our understanding of the UCN source parameters by performing a series of studies to characterize neutron production and moderation, and UCN production, extraction, and transport efficiency to the beamport. The present study on the absolute UCN transport efficiency completes our previous publications. We report on complementary measurements, namely one on the height-dependent UCN density and a second on the transmission of a calibrated quantity of UCN over a ~16 m long UCN guide section connecting one beamport via the source storage vessel to another beamport. These allow us quantifying and optimizing the performance of the guide system based on extensive Monte Carlo simulations.

preprint2020arXiv

Measurement of the permanent electric dipole moment of the neutron

We present the result of an experiment to measure the electric dipole moment (EDM) of the neutron at the Paul Scherrer Institute using Ramsey's method of separated oscillating magnetic fields with ultracold neutrons (UCN). Our measurement stands in the long history of EDM experiments probing physics violating time reversal invariance. The salient features of this experiment were the use of a Hg-199 co-magnetometer and an array of optically pumped cesium vapor magnetometers to cancel and correct for magnetic field changes. The statistical analysis was performed on blinded datasets by two separate groups while the estimation of systematic effects profited from an unprecedented knowledge of the magnetic field. The measured value of the neutron EDM is $d_{\rm n} = (0.0\pm1.1_{\rm stat}\pm0.2_{\rm sys})\times10^{-26}e\,{\rm cm}$.

preprint2020arXiv

Optically Pumped Cs Magnetometers Enabling a High-Sensitivity Search for the Neutron Electric Dipole Moment

An array of sixteen laser-pumped scalar Cs magnetometers was part of the neutron electric dipole moment (nEDM) experiment taking data at the Paul Scherrer Institute in 2015 and 2016. It was deployed to measure the gradients of the experiment's magnetic field and to monitor their temporal evolution. The originality of the array lies in its compact design, in which a single near-infrared diode laser drives all magnetometers that are located in a high-vacuum chamber, with a selection of the sensors mounted on a high-voltage electrode. We describe details of the Cs sensors' construction and modes of operation, emphasizing the accuracy and sensitivity of the magnetic field readout. We present two applications of the magnetometer array directly beneficial to the nEDM experiment: (i) the implementation of a strategy to correct for the drift of the vertical magnetic field gradient and (ii) a procedure to homogenize the magnetic field. The first reduces the uncertainty of the new nEDM result. The second enables transverse neutron spin relaxation times exceeding 1500 s, improving the statistical sensitivity of the nEDM experiment by about 35% and effectively increasing the rate of nEDM data taking by a factor of 1.8.

preprint2019arXiv

Neutron optics of the PSI ultracold neutron source: characterization and simulation

The ultracold neutron (UCN) source at the Paul Scherrer Institute serves mainly experiments in fundamental physics. High UCN intensities are the key for progress and success in such experiments. A detailed understanding of all source parameters is required for future improvements. Here we present the UCN source components, elements of the neutron optics, the characterization of important related parameters like emptying times, storage times or transmission probabilities of UCN which are ultimately defining the UCN intensity delivered at the beamports. We also introduce a detailed simulation model of the PSI UCN source, used to analyze the measurements and to extract surface parameters.

preprint2019arXiv

The n2EDM experiment at the Paul Scherrer Institute

We present the new spectrometer for the neutron electric dipole moment (nEDM) search at the Paul Scherrer Institute (PSI), called n2EDM. The setup is at room temperature in vacuum using ultracold neutrons. n2EDM features a large UCN double storage chamber design with neutron transport adapted to the PSI UCN source. The design builds on experience gained from the previous apparatus operated at PSI until 2017. An order of magnitude increase in sensitivity is calculated for the new baseline setup based on scalable results from the previous apparatus, and the UCN source performance achieved in 2016.

preprint2018arXiv

nEDM experiment at PSI: data-taking strategy and sensitivity of the dataset

We report on the strategy used to optimize the sensitivity of our search for a neutron electric dipole moment at the Paul Scherrer Institute. Measurements were made upon ultracold neutrons stored within a single chamber at the heart of our apparatus. A mercury cohabiting magnetometer together with an array of cesium magnetometers were used to monitor the magnetic field, which was controlled and shaped by a series of precision field coils. In addition to details of the setup itself, we describe the chosen path to realize an appropriate balance between achieving the highest statistical sensitivity alongside the necessary control on systematic effects. The resulting irreducible sensitivity is better than 1*10-26 ecm. This contribution summarizes in a single coherent picture the results of the most recent publications of the collaboration.