Researcher profile

P. Olko

P. Olko contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Proton radiographs using position-sensitive silicon detectors and high-resolution scintillators

Proton therapy is a cancer treatment technique currently in growth worldwide. It offers advantages with respect to conventional X-ray and $γ$-ray radiotherapy, in particular, a better control of the dose deposition allowing to reach a higher conformity in the treatments. Therefore, it causes less damage to the surrounding healthy tissue and less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton Computed Tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Here, results obtained from an experiment performed using a 100-MeV proton beam at the CCB facility in Krakow (Poland) are presented. Proton radiographs of PMMA samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution and sensitivity to different materials. They demonstrate the capabilities of the system to produce images with protons. Structures of up to 2 mm are nicely resolved and the sensitivity of the system was enough to distinguish thicknesses of 10 mm of aluminum or PMMA. This constitutes a first step to validate the device as a proton radiography scanner previous to the future tests as a proton CT scanner.

preprint2021arXiv

The influence of nuclear models and Monte Carlo radiation transport codes on stray neutron dose estimations in proton therapy

This study investigates the influence of several Monte Carlo radiation transport codes and nuclear models on the simulation of secondary neutron spectra and its impact on calculating and measuring neutron doses in proton therapy. Three different multi-purpose Monte Carlo radiation transport codes (FLUKA, MCNPX, Geant4) were used with different available nuclear models to calculate secondary neutron energy spectra at various points inside a water tank phantom with PMMA walls using a 10 cm x 10 cm rectangular, mono-energetic proton beam (110, 150, 180, and 210 MeV). Using Kerma approximation secondary neutron doses were calculated applying fluence-to-dose equivalent conversion coefficients in water. Moreover, the impact of varying spectra for electrochemically etched CR39 detector calibration was analyzed for different codes and models. In distal positions beyond the Bragg peak, results show largest variations between the codes, up to 53% for the high energy neutron fluence at 16 cm from the Bragg peak of the 110 MeV proton beam. In lateral positions, the variation between the codes is smaller and for the total neutron fluence within 20%. Variation in the nuclear models in MCNPX was only visible for the proton beam energies of 180 and 210 MeV and modeling the high energy neutron fluence which reached up to 23% for 210 MeV at 11 cm lateral from the beam axis. Impact on neutron dose equivalent was limited for the different models used (<8%) while it was pronounced for the different codes (45% at 16 cm from the Bragg peak of the 110 MeV proton beam). CR39 calibration factors in lateral positions were on average varying 10% between codes and 5 % between nuclear models.This study demonstrated a large impact on the neutron fluence spectra calculated by different codes while the impact of different models in MCNPX proved to be less prominent for the neutron modeling in proton therapy.

preprint2020arXiv

Mapping the Future of Particle Radiobiology in Europe: The INSPIRE Project

Particle therapy is a growing cancer treatment modality worldwide. However, there still remains a number of unanswered questions considering differences in the biological response between particles and photons. These questions, and probing of biological mechanisms in general, necessitate experimental investigation. The Infrastructure in Proton International Research (INSPIRE) project was created to provide an infrastructure for European research, unify research efforts on the topic of proton and ion therapy across Europe, and to facilitate the sharing of information and resources. This work highlights the radiobiological capabilities of the INSPIRE partners, providing details of physics (available particle types and energies), biology (sample preparation and post-irradiation analysis), and researcher access (the process of applying for beam time). The collection of information reported here is designed to provide researchers both in Europe and worldwide with the tools required to select the optimal center for their research needs. We also highlight areas of redundancy in capabilities and suggest areas for future investment.