Source author record

P. E. Knowles

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

5works
4topics
4close collaborators

Published work

5 publications

preprint2007arXiv

Characterization of large area avalanche photodiodes in X-ray and VUV-light detection

The present manuscript summarizes novel studies on the application of large area avalanche photodiodes (LAAPDs) to the detection of X-rays and vacuum ultraviolet (VUV) light. The operational characteristics of four different LAAPDs manufactured by Advanced Photonix Inc., with active areas of 80 and 200 mm^2 were investigated for X-ray detection at room temperature. The best energy resolution was found to be in the 10-18% range for 5.9 keV X-rays. The LAAPD, being compact, simple to operate and with high counting rate capability (up to about 10^5/s), proved to be useful in several applications, such as low-energy X-ray detection, where they can reach better performance than proportional counters. Since X-rays are used as reference in light measurements, the gain non-linearity between 5.9 keV X-rays and light pulses was investigated. The gain ratio between X-rays and VUV light decreases with gain, reaching 10 and 6% variations for VUV light produced in argon (~128 nm) and xenon (~172 nm), respectively, for a gain 200, while for visible light (~635 nm) the variation is lower than 1%. The effect of temperature on the LAAPD performance was investigated. Relative gain variations of about -5% per Celsius degree were observed for the highest gains. The excess noise factor was found to be independent on temperature, being between 1.8 and 2.3 for gains from 50 to 300. The energy resolution is better for decreasing temperatures due mainly to the dark current. LAAPDs were tested under intense magnetic fields up to 5 T, being insensitive when used in X-ray and visible-light detection, while for VUV light a significant amplitude reduction was observed at 5 T.

preprint2006arXiv

Muonic hydrogen cascade time and lifetime of the short-lived 2S2S state

Metastable 2S{2S} muonic-hydrogen atoms undergo collisional 2S{2S}-quenching, with rates which depend strongly on whether the μpμp kinetic energy is above or below the 2S→2P{2S}\to {2P} energy threshold. Above threshold, collisional 2S→2P{2S} \to {2P} excitation followed by fast radiative 2P→1S{2P} \to {1S} deexcitation is allowed. The corresponding short-lived μp(2S)μp ({2S}) component was measured at 0.6 hPa H2\mathrm{H}_2 room temperature gas pressure, with lifetime τ2Sshort=165−29+38τ_{2S}^\mathrm{short} = 165 ^{+38}_{-29} ns (i.e., λ2Squench=7.9−1.6+1.8×1012s−1λ_{2S}^\mathrm{quench} = 7.9 ^{+1.8}_{-1.6} \times 10^{12} \mathrm{s}^{-1} at liquid-hydrogen density) and population ε2Sshort=1.70−0.56+0.80ε_{2S}^\mathrm{short} = 1.70^{+0.80}_{-0.56} % (per μpμp atom). In addition, a value of the μpμp cascade time, Tcasμp=(37±5)T_\mathrm{cas}^{μp} = (37\pm5) ns, was found.

preprint2004arXiv

Method of Monte Carlo grid for data analysis

This paper presents an analysis procedure for experimental data using theoretical functions generated by Monte Carlo. Applying the classical chi-square fitting procedure for some multiparameter systems is extremely difficult due to a lack of an analytical expression for the theoretical functions describing the system. The proposed algorithm is based on the least square method using a grid of Monte Carlo generated functions each corresponding to definite values of the minimization parameters. It is used for the E742 experiment (TRIUMF, Vancouver, Canada) data analysis with the aim to extract muonic atom scattering parameters on solid hydrogen.

preprint2003arXiv

Experimental study of μμ--atomic and μμ--molecular processes in pure helium and deuterium--helium mixtures

We present experimental results of μμ--atomic and μμ--molecular processes induced by negative muons in pure helium and helium--deuterium mixtures. The experiment was performed at the Paul Scherrer Institute (Switzerland). We measured muonic x--ray KK series transitions relative intensities in (μ3,4He)∗(μ^{3,4}\mathrm{He})^* atoms in pure helium as well as in helium--deuterium mixture. The muon stopping powers ratio between helium and deuterium atoms and the dμ3Hed μ^3 \mathrm{He} radiative decay probability of for two different helium densities in D2+3He\mathrm{D}_2 + {}^3\mathrm{He} mixture were also determined. Finally, the q1sHe\mathrm{q}_{1s}^{\mathrm{He}} probability for a dμdμ atom formed in an excited state to reach the ground state was measured and compared with theoretical calculations using a simple cascade model.

preprint1996arXiv

Characterization of Solidified Gas Thin Film Targets via Alpha Particle Energy Loss

A method is reported for measuring the thickness and uniformity of thin films of solidified gas targets. The energy of alpha particles traversing the film is measured and the energy loss is converted to thickness using the stopping power. The uniformity is determined by measuring the thickness at different positions with an array of sources. Monte Carlo simulations have been performed to study the film deposition mechanism. Thickness calibrations for a TRIUMF solid hydrogen target system are presented.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.