Source author record

P. Berg

P. Berg appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Central moments multiple relaxation time LBM for hemodynamic simulations in intracranial aneurysms: An in-vitro validation study using PIV and PC-MRI

The lattice Boltzmann method (LBM) has recently emerged as an efficient alternative to classical Navier-Stokes solvers. This is particularly true for hemodynamics in complex geometries. However, in its most basic formulation, {i.e.} with the so-called single relaxation time (SRT) collision operator, it has been observed to have a limited stability domain in the Courant/Fourier space, strongly constraining the minimum time-step and grid size. The development of improved collision models such as the multiple relaxation time (MRT) operator in central moments space has tremendously widened the stability domain, while allowing to overcome a number of other well-documented artifacts, therefore opening the door for simulations over a wider range of grid and time-step sizes. The present work focuses on implementing and validating a specific collision operator, the central Hermite moments multiple relaxation time model with the full expansion of the equilibrium distribution function, to simulate blood flows in intracranial aneurysms. The study further proceeds with a validation of the numerical model through different test-cases and against experimental measurements obtained via stereoscopic particle image velocimetry (PIV) and phase-contrast magnetic resonance imaging (PC-MRI). For a patient-specific aneurysm both PIV and PC-MRI agree fairly well with the simulation. Finally, low-resolution simulations were shown to be able to capture blood flow information with sufficient accuracy, as demonstrated through both qualitative and quantitative analysis of the flow field {while leading to strongly reduced computation times. For instance in the case of the patient-specific configuration, increasing the grid-size by a factor of two led to a reduction of computation time by a factor of 14 with very good similarity indices still ranging from 0.83 to 0.88.}

preprint2010arXiv

Phase-locking of two self-seeded tapered amplifier lasers

We report on the phase-locking of two diode lasers based on self-seeded tapered amplifiers. In these lasers, a reduction of linewidth is achieved using narrow-band high-transmission interference filters for frequency selection. The lasers combine a compact design with a Lorentzian linewidth below 200 kHz at an output power of 300 mW. We characterize the phase noise of the phase-locked laser system and study its potential for coherent beam-splitting in atom interferometers.