Researcher profile

Omer Burak Demirel

Omer Burak Demirel contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Multi-Mask Self-Supervised Learning for Physics-Guided Neural Networks in Highly Accelerated MRI

Self-supervised learning has shown great promise due to its capability to train deep learning MRI reconstruction methods without fully-sampled data. Current self-supervised learning methods for physics-guided reconstruction networks split acquired undersampled data into two disjoint sets, where one is used for data consistency (DC) in the unrolled network and the other to define the training loss. In this study, we propose an improved self-supervised learning strategy that more efficiently uses the acquired data to train a physics-guided reconstruction network without a database of fully-sampled data. The proposed multi-mask self-supervised learning via data undersampling (SSDU) applies a hold-out masking operation on acquired measurements to split it into multiple pairs of disjoint sets for each training sample, while using one of these pairs for DC units and the other for defining loss, thereby more efficiently using the undersampled data. Multi-mask SSDU is applied on fully-sampled 3D knee and prospectively undersampled 3D brain MRI datasets, for various acceleration rates and patterns, and compared to CG-SENSE and single-mask SSDU DL-MRI, as well as supervised DL-MRI when fully-sampled data is available. Results on knee MRI show that the proposed multi-mask SSDU outperforms SSDU and performs closely with supervised DL-MRI. A clinical reader study further ranks the multi-mask SSDU higher than supervised DL-MRI in terms of SNR and aliasing artifacts. Results on brain MRI show that multi-mask SSDU achieves better reconstruction quality compared to SSDU. Reader study demonstrates that multi-mask SSDU at R=8 significantly improves reconstruction compared to single-mask SSDU at R=8, as well as CG-SENSE at R=2.

preprint2020arXiv

A Blind Deconvolution Technique Based on Projection Onto Convex Sets for Magnetic Particle Imaging

Magnetic Particle Imaging (MPI) is an emerging imaging modality that maps the spatial distribution of magnetic nanoparticles. The x-space reconstruction in MPI results in highly blurry images, where the resolution depends on both system parameters and nanoparticle type. Previous techniques to counteract this blurring rely on the knowledge of the imaging point spread function (PSF), which may not be available or may require additional measurements. This work proposes a blind deconvolution algorithm for MPI to recover the precise spatial distribution of nanoparticles. The proposed algorithm exploits the observation that the imaging PSF in MPI has zero phase in Fourier domain. Thus, even though the reconstructed images are highly blurred, phase remains unaltered. We leverage this powerful property to iteratively enforce consistency of phase and bounded l1 energy information, using an orthogonal Projections Onto Convex Sets (POCS) algorithm. To demonstrate the method, comprehensive simulations were performed without and with nanoparticle relaxation effects, and at various noise levels. In addition, imaging experiments were performed on an in-house MPI scanner using a three-vial phantom that contained different nanoparticle types. Image quality was compared with conventional deconvolution methods, Wiener deconvolution and Lucy-Richardson method, which explicitly rely on the knowledge of PSF. Both the simulation results and experimental imaging results show that the proposed blind deconvolution algorithm outperforms the conventional deconvolution methods. Without utilizing the imaging PSF, the proposed algorithm improves image quality and resolution even in the case of different nanoparticle types, while displaying reliable performance against loss of the fundamental harmonic, nanoparticle relaxation effects, and noise.