Researcher profile

O. Usenko

O. Usenko contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Atomic resolution STM in a cryogen free dilution refrigerator at 15 mK

Pulse tube refrigerators are becoming more common, because they are cost efficient and demand less handling than conventional (wet) refrigerators. However, a downside of a pulse tube system is the vibration level at the cold-head, which is in most designs several micrometers. We implemented vibration isolation techniques which significantly reduced vibration levels at the experiment. These optimizations were necessary for the vibration sensitive Magnetic Resonance Force Microscopy experiments (MRFM) at milli-kelvin temperatures for which the cryostat is intended. With these modifications we show atomic resolution STM on graphite. This is promising for scanning probe microscopy applications at very low temperatures.

preprint2011arXiv

Magnetic Resonance Force Microscopy of paramagnetic electron spins at millikelvin temperatures

Magnetic Resonance Force Microscopy (MRFM) is a powerful technique to detect a small number of spins that relies on force-detection by an ultrasoft magnetically tipped cantilever and selective magnetic resonance manipulation of the spins. MRFM would greatly benefit from ultralow temperature operation, because of lower thermomechanical noise and increased thermal spin polarization. Here, we demonstrate MRFM operation at temperatures as low as 30 mK, thanks to a recently developed SQUID-based cantilever detection technique which avoids cantilever overheating. In our experiment, we detect dangling bond paramagnetic centers on a silicon surface down to millikelvin temperatures. Fluctuations of such kind of defects are supposedly linked to 1/f magnetic noise and decoherence in SQUIDs as well as in several superconducting and single spin qubits. We find evidence that spin diffusion plays a key role in the low temperature spin dynamics.

preprint2010arXiv

A SQUID based read-out of sub-attoNewton force sensor operating at millikelvin temperatures

An increasing number of experiments require the use of ultrasensitive nanomechanical resonators. Relevant examples are the investigation of quantum effects in mechanical systems [1] or the detection of exceedingly small forces as in Magnetic Resonance Force Microscopy (MRFM) [2]. The force sensitivity of a mechanical resonator is typically limited by thermal fluctuations, which calls for detection methods capable of operating at ultralow temperature. Commonly used interferometric techniques, despite their excellent sensitivity, may not be an optimal choice at millikelvin temperatures, because of unwanted resonator heating caused by photon absorption. Although alternative detection techniques based on microwave cavities [3] [4] [5] have shown to perform better at ultralow temperature, these techniques still suffer from the fact that the detection sensitivity decreases as the power input is decreased. Here, we present a measurement approach based on the detection, through a Superconducting Quantum Interference Device (SQUID), of the change of magnetic flux induced in a coil by the motion of a magnetic particle attached to a resonator. This detection scheme avoids direct heating of the resonator, as it does not involve reflecting optical or microwave photons to the resonator. By cooling an ultrasoft silicon resonator to 25 mK, we achieve a force noise of 0.5 aN in a 1 Hz bandwidth. We believe this detection technique can in principle be used even at sub-millikelvin temperatures. Furthermore, it could be used to improve the sensitivity of MRFM experiments, which aim at three dimensional imaging at atomic resolution.