Researcher profile

O. Tkach

O. Tkach contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2026arXiv

Asymmetric Electrostatic Dodecapole: Compact Bandpass Filter with Low Aberrations for Momentum Microscopy

Imaging energy filters in photoelectron microscopes and momentum microscopes use spherical fields with deflection angles of 90°, 180°, and even 2 x 180°. These instruments are optimized for high energy resolution, but exhibit image aberrations when operated in high transmission mode at medium energy resolution. Here we present a new approach for bandpass-filtered imaging in real or reciprocal space using an electrostatic dodecapole with an asymmetric electrode array. In addition to energy-dispersive beam deflection, this multipole allows aberration correction up to the 3rd order. Here we describe its use as a bandpass prefilter in a time-of-flight momentum microscope at the hard X-ray beamline P22 of PETRA III. The entire instrument is housed in a straight vacuum tube because the deflection angle is only 4° and the beam displacement in the filter is only 8 mm. The multipole is framed by transfer lenses in the entrance and exit branches. Two sets of 16 different sized entrance and exit apertures on piezomotor driven mounts allow selection of the desired bandpass. For pass energies between 100 and 1400 eV and slit widths between 0.5 and 4 mm the transmitted kinetic energy intervals are between 10 eV and a few hundred eV (FWHM). The filter eliminates all higher or lower energy signals outside the selected bandpass, significantly improving the signal-to-background ratio in the ToF analyzer.

preprint2026arXiv

Multimode Objective Lens for Momentum Microscopy and XPEEM: Experiments

A new type of objective lens has recently been proposed for use in X-ray photoemission electron microscopes (XPEEMs) and momentum microscopes. Adding a ring electrode concentric with the extractor allows the field in the gap between the sample and the extractor to be shaped. Forming a lens field in this gap reduces the field strength at the sample by up to an order of magnitude. This mitigates the risk of field emission, particularly for cleaved samples with sharp edges. A retarding field can redirect all slow electrons, thus eliminating the primary contribution to the space-charge interaction. Here we present the first experimental investigation of the new lens, examining its performance at photon energies ranging from the extreme ultraviolet produced by a high-harmonic generation (HHG)-based source to soft and hard X-rays at two synchrotron facilities. The gap lens in a region without electrodes enables large working distances up to 23 mm. Reduced aberrations allow for larger fields of view in both k-space and real-space imaging, with resolutions comparable to those of conventional cathode lenses. However, field strengths are an order of magnitude smaller. The zero-field mode enables the study of 3D structured objects and is therefore beneficial for small cleaved samples as well as for operando devices involving top electrodes. The repeller mode reduces space-charge effects, but results in a smaller k-field diameter. This reduction ranges from 10% at hard X-ray energies to 50% in the XUV range. The usable energy interval is also reduced by a factor of two. In time-of-flight XPEEM mode the raw data show a resolution of 250 nm, which can be improved to better than 100 nm through data processing.