Researcher profile

O. Marrufo

O. Marrufo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Experimental development and evaluation of a volume coil with slotted end-rings coil for rat MRI at 7 T

A volume coil with squared slots-end ring was developed to attain improved sensitivity for imaging of rat's brain at 7 T. The principles of the high cavity resonator for the low-pass case and the law of Biot-Savart were used to derive a theoretical expression of the coil sensitivity. The slotted-end ring resonator showed a theoretical 2.22-fold improvement over the standard birdcage coil with similar dimensions. Numerical studies were carried out for the electromagnetic fields and specific absorption rates for our coil and a birdcage coil loaded with a saline-filled cylindrical phantom and a digital brain of a rat. An improvement of the signal-to-noise ratio (SNR) can be observed for the slotted volume coil over the birdcage regardless of the load used in the electromagnetic simulations. The specific absorption rate simulations show an important decrement for the digital brain and quite similar values with the saline solution phantom. Phantom and rat's brain images were acquired at 7 T to prove the viability of the coil design. The experimental noise figure of our coil design was four times less than the standard birdcage with similar dimensions, witch showed a 30% increase in experimental SNR. There is remarkable agreement among the theoretical, numerical and experimental sensitivity values, which all demonstrate that the coil performance for MR imaging of small rodents can be improved using slotted end-rings.

preprint2013arXiv

Travelling Wave Magnetic Resonance Imaging at 3 Tesla

Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transversal electric modes and it can propagate any frequency. To investigate the potential benefits for whole-body imaging at 3 T, we compare numerical simulations at 1.5 T, 3 T, 7 T, and 9 T via the propagation of the parallel-plate waveguide principal mode filled with a cylindrical phantom and two surface coils. B1 mapping was computed to investigate the feasibility of this approach at 3T. The point spread function method was used to measure the imager performance for the traveling-wave magnetic resonance imaging experiment. Human leg images were acquired to experimentally validate this approach. The principal mode shows very little field magnitude variations along the propagation direction at 3 T when compared to other higher resonant frequencies. The B1 mapping showed that it is possible to conduct experiments using the traveling-wave approach at 128 MHz. The point spread function results showed a good scanner performance for these type of experiments. Leg images were obtained with the whole-body birdcage coil and the waveguide with two circular coils for comparison purposes. The simulated and in vivo traveling-wave results correspond very well for both magnetic field and specific absorption rate. A pretty similar performance was observed for the traveling-wave approach and the conventional one. We have demonstrated the feasibility of traveling-wave magnetic resonance imaging at 3T for whole-body magnetic resonance systems, using a parallel-plate waveguide with standard pulse sequences and only one coil array.