Researcher profile

Niek R. F. Huttinga

Niek R. F. Huttinga contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2023arXiv

Towards retrospective motion correction and reconstruction for clinical 3D brain MRI protocols with a reference contrast

Motion artifacts often spoil the radiological interpretation of MR images, and in the most severe cases the scan needs be repeated, with additional costs for the provider. We discuss the application of a novel 3D retrospective rigid motion correction and reconstruction scheme for MRI, which leverages multiple scans contained in a MR session. Typically, in a multi-contrast MR session, motion does not equally affect all the scans, and some motion-free scans are generally available, so that we can exploit their anatomic similarity. The uncorrupted scan is used as a reference in a generalized rigid-motion registration problem to remove the motion artifacts affecting the corrupted scans. We discuss the potential of the proposed algorithm with a prospective in-vivo study and clinical 3D brain protocols. This framework can be easily incorporated into the existing clinical practice with no disruption to the conventional workflow.

preprint2022arXiv

Gaussian Processes for real-time 3D motion and uncertainty estimation during MR-guided radiotherapy

Respiratory motion during radiotherapy causes uncertainty in the tumor's location, which is typically addressed by an increased radiation area and a decreased dose. As a result, the treatments' efficacy is reduced. The recently proposed hybrid MR-linac scanner holds the promise to efficiently deal with such respiratory motion through real-time adaptive MR-guided radiotherapy (MRgRT). For MRgRT, motion-fields should be estimated from MR-data and the radiotherapy plan should be adapted in real-time according to the estimated motion-fields. All of this should be performed with a total latency of maximally 200 ms, including data acquisition and reconstruction. A measure of confidence in such estimated motion-fields is highly desirable, for instance to ensure the patient's safety in case of unexpected and undesirable motion. In this work, we propose a framework based on Gaussian Processes to infer 3D motion-fields and uncertainty maps in real-time from only three readouts of MR-data. We demonstrated an inference frame rate up to 69 Hz including data acquisition and reconstruction, thereby exploiting the limited amount of required MR-data. Additionally, we designed a rejection criterion based on the motion-field uncertainty maps to demonstrate the framework's potential for quality assurance. The framework was validated in silico and in vivo on healthy volunteer data (n=5) acquired using an MR-linac, thereby taking into account different breathing patterns and controlled bulk motion. Results indicate end-point-errors with a 75th percentile below 1mm in silico, and a correct detection of erroneous motion estimates with the rejection criterion. Altogether, the results show the potential of the framework for application in real-time MR-guided radiotherapy with an MR-linac.

preprint2020arXiv

Non-rigid 3D motion estimation at high temporal resolution from prospectively undersampled k-space data using low-rank MR-MOTUS

With the recent introduction of the MR-LINAC, an MR-scanner combined with a radiotherapy LINAC, MR-based motion estimation has become of increasing interest to (retrospectively) characterize tumor and organs-at-risk motion during radiotherapy. To this extent, we introduce low-rank MR-MOTUS, a framework to retrospectively reconstruct time-resolved non-rigid 3D+t motion-fields from a single low-resolution reference image and prospectively undersampled k-space data acquired during motion. Low-rank MR-MOTUS exploits spatio-temporal correlations in internal body motion with a low-rank motion model, and inverts a signal model that relates motion-fields directly to a reference image and k-space data. The low-rank model reduces the degrees-of-freedom, memory consumption and reconstruction times by assuming a factorization of space-time motion-fields in spatial and temporal components. Low-rank MR-MOTUS was employed to estimate motion in 2D/3D abdominothoracic scans and 3D head scans. Data were acquired using golden-ratio radial readouts. Reconstructed 2D and 3D respiratory motion-fields were respectively validated against time-resolved and respiratory-resolved image reconstructions, and the head motion against static image reconstructions from fully-sampled data acquired right before and right after the motion. Results show that 2D+t respiratory motion can be estimated retrospectively at 40.8 motion-fields-per-second, 3D+t respiratory motion at 7.6 motion-fields-per-second and 3D+t head-neck motion at 9.3 motion-fields-per-second. The validations show good consistency with image reconstructions. The proposed framework can estimate time-resolved non-rigid 3D motion-fields, which allows to characterize drifts and intra and inter-cycle patterns in breathing motion during radiotherapy, and could form the basis for real-time MR-guided radiotherapy.

preprint2019arXiv

Model-based reconstruction of non-rigid 3D motion-fields from minimal $k$-space data: MR-MOTUS

Estimation of internal body motion with high spatio-temporal resolution can greatly benefit MR-guided radiotherapy/interventions and cardiac imaging, but remains a challenge to date. In image-based methods, where motion is indirectly estimated by reconstructing and co-registering images, a trade off between spatial and temporal resolution of the motion-fields has to be made due to the image reconstruction step. However, we observe that motion-fields are very compressible due to the spatial correlation of internal body motion. Therefore, reconstructing only motion-fields directly from surrogate signals or k-space data without the need for image reconstruction should require few data, and could eventually result in high spatio-temporal resolution motion-fields. In this work we introduce MR-MOTUS, a framework that makes exactly this possible. The two main innovations of this work are (1) a signal model that explicitly relates the k-space signal of a deforming object to general non-rigid motion-fields, and (2) model-based reconstruction of motion-fields directly from highly undersampled k-space data by solving the corresponding inverse problem. The signal model is derived by modeling a deforming object as a static reference object warped by dynamic motion-fields, such that the dynamic signal is given explicitly in terms of motion-fields. We validate the signal model through numerical experiments with an analytical phantom, and reconstruct motion-fields from retrospectively undersampled in-vivo data. Results show that the reconstruction quality is comparable to state-of-the-art image registration for undersampling factors as high as 63 for 3D non-rigid respiratory motion and as high as 474 for 3D rigid head motion.