Researcher profile

Nicolò Crescini

Nicolò Crescini contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

An Haloscope Amplification Chain based on a Travelling Wave Parametric Amplifier

In this paper we will describe the characterisation of a rf detection chain based on a travelling wave parametric amplifier (TWPA). The detection chain is meant to be used for dark matter axion searches and thus it is mounted coupled to a high Q microwave resonant cavity. A system noise temperature $T_{\rm sys} = (3.3 \pm 0.1$) K has been measured at a frequency of 10.77 GHz, using a novel scheme allowing measurement of $T_{\rm sys} $ exactly at the cavity output port.

preprint2022arXiv

Building instructions for a ferromagnetic axion haloscope

A ferromagnetic haloscope is a rf spin-magnetometer used for searching Dark Matter in the form of axions. A magnetic material is monitored searching for anomalous magnetization oscillations which can be induced by dark matter axions. To properly devise such instrument one first needs to understand the features of the searched-for signal, namely the effective rf field of dark matter axions $B_a$ acting on electronic spins. Once the properties of $B_a$ are defined, the design and test of the apparatus may start. The optimal sample is a narrow linewidth and high spin-density material such as Yttrium Iron Garnet (YIG), coupled to a microwave cavity with almost matched linewidth to collect the signal. The power in the resonator is collected with an antenna and amplified with a Josephson Parametric amplifier, a quantum-limited device which, however, adds most of the setup noise. The signal is further amplified with low noise HEMT and down-converted for storage with an heterodyne receiver. This work describes how to build such apparatus, with all the experimental details, the main issues one might face, and some solutions.

preprint2022arXiv

Coherent coupling between multiple ferrimagnetic spheres and a microwave cavity in the quantum-limit

The spin resonance of electrons can be coupled to a microwave cavity mode to obtain a photon-magnon hybrid system. These quantum systems are widely studied for both fundamental physics and technological quantum applications. In this article, the behavior of a large number of ferrimagnetic spheres coupled to a single cavity is put under test. We use second-quantization modeling of harmonic oscillators to theoretically describe our experimental setup and understand the influence of several parameters. The magnon-polariton dispersion relation is used to characterize the system, with a particular focus on the vacuum Rabi mode splitting due to multiple spheres. We combine the results obtained with simple hybrid systems to analyze the behavior of a more complex one, and show that it can be devised in such a way to minimize the degrees of freedom needed to completely describe it. By studying single-sphere coupling two possible size-effects related to the sample diameter have been identified, while multiple-spheres configurations reveal how to upscale the system. This characterization is useful for the implementation of an axion-to-electromagnetic field transducer in a ferromagnetic haloscope for dark matter searches. Our dedicated setup, consisting in ten 2 mm-diameter YIG spheres coupled to a copper microwave cavity, is used for this aim and studied at mK temperatures. Moreover, we show that novel applications of optimally-controlled hybrid systems can be foreseen for setups embedding a large number of samples.

preprint2022arXiv

Phase-modulated cavity magnon polaritons as a precise magnetic field probe

We describe and operate a novel spin-magnetometer based on the phase modulation of cavity magnon polaritons. In this scheme a rf magnetic field is detected through the sidebands it induces on a pump, and the experimental configuration allows for a negligible pump noise and a high frequency readout. The demonstrator setup, based on a copper cavity coupled to an yttrium iron garnet sphere hybrid system, reached a sensitivity of $2.0\,\mathrm{pT/\sqrt{Hz}}$, evading the pump noise and matching the theoretical previsions. An optimized setup can attain a rf magnetic field sensitivity of about $8\,\mathrm{fT/\sqrt{Hz}}$ at room temperature. An orders of magnitude improvement is expected at lower temperatures, making this instrument one of the few magnetometers accessing the sub-fT limit. Due to its natural applications, miniaturization and multiplexing are eventually discussed.