Researcher profile

Nicholas Zobrist

Nicholas Zobrist contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors

Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and estimating each photon's energy. The resolving power of non-membrane MKIDs has remained stubbornly around 10 at 1 $μ$m despite significant improvements in the system noise. Here we show that the resolving power can be roughly doubled with a simple bilayer design without needing to place the device on a membrane, avoiding a significant increase in fabrication complexity. Based on modeling of the phonon propagation, we find that the majority of the improvement comes from the inability of high energy phonons to enter the additional layer due to the lack of available phonon states.

preprint2022arXiv

Readout of a quantum processor with high dynamic range Josephson parametric amplifiers

We demonstrate a high dynamic range Josephson parametric amplifier (JPA) in which the active nonlinear element is implemented using an array of rf-SQUIDs. The device is matched to the 50 $Ω$ environment with a Klopfenstein-taper impedance transformer and achieves a bandwidth of 250-300 MHz, with input saturation powers up to -95 dBm at 20 dB gain. A 54-qubit Sycamore processor was used to benchmark these devices, providing a calibration for readout power, an estimate of amplifier added noise, and a platform for comparison against standard impedance matched parametric amplifiers with a single dc-SQUID. We find that the high power rf-SQUID array design has no adverse effect on system noise, readout fidelity, or qubit dephasing, and we estimate an upper bound on amplifier added noise at 1.6 times the quantum limit. Lastly, amplifiers with this design show no degradation in readout fidelity due to gain compression, which can occur in multi-tone multiplexed readout with traditional JPAs.

preprint2021arXiv

Improving the energy resolution of photon counting Microwave Kinetic Inductance Detectors using principal component analysis

We develop a photon energy measurement scheme for single photon counting Microwave Kinetic Inductance Detectors (MKIDs) that uses principal component analysis (PCA) to measure the energy of an incident photon from the signal ("photon pulse") generated by the detector. PCA can be used to characterize a photon pulse using an arbitrarily large number of features and therefore PCA-based energy measurement does not rely on the assumption of an energy-independent pulse shape that is made in standard filtering techniques. A PCA-based method for energy measurement is especially useful in applications where the detector is operating near its saturation energy and pulse shape varies strongly with photon energy. It has been shown previously that PCA using two principal components can be used as an energy-measurement scheme. We extend upon these ideas and develop a method for measuring the energies of photons by characterizing their pulse shapes using any number of principal components and any number of calibration energies. Applying this technique with 50 principal components, we show improvements to a previously-reported energy resolution for Thermal Kinetic Inductance Detectors (TKIDs) from 75 eV to 43 eV at 5.9 keV. We also apply this technique with 50 principal components to data from an optical to near-IR MKID and achieve energy resolutions that are consistent with the best results from existing analysis techniques.

preprint2020arXiv

Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays

Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax

preprint2020arXiv

Improving the dynamic range of single photon counting kinetic inductance detectors

We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium MKID designed to be sensitive to photons with wavelengths in the 800 to 1300 nm range. The new coordinates allow the detector to resolve photons with wavelengths down to 400 nm, raising the resolving power at that wavelength from 6.8 to 17.